Michigan City, Indiana
Technician Invoice Notes: Investigated And Found 1/2” Cpvc Male Adapter To 1/2” Pvc Female Adapter Leaking Due To Pvc Adapter Split. Removed Cpvc And Pvc From Gate Valves. Installed New Stop Valves And Supply Lines To Faucet. Pressurized And Tested Repair.
MICHIGAN CITY, IN
08-20-2020
Michigan City, Indiana
Technician Invoice Notes: Upon Arrival Found Failed 1 1/4” P Trap With 1 1/2” Clamp Holding 3/8” Discharge For Water Machine. In Order To Install 1 1/2” P Trap Removed Section Of Wall And Installed New 1 1/2” Male Adapter With Appropriate Fittings. Re Attached 3/8” Discharge For Water Machine Onto 1 1/2” P Trap. Tested Operation Of Repair By Cycling Water With No Issues At This Time.
MICHIGAN CITY, IN
08-20-2020
Michigan City, Indiana
Technician Invoice Notes:investigated And Found Well Tank Failed. Removed And Replaced Tank With Well Mate 6 Well Tank. Installed New Piping From New Tank To Existing Well Piping. Installed New Pressure Gauge Into Existing Location.Pressurized System And Inspected Installation.
Tank Model WM-6
PART 34718
SERIAL 140208818
Michigan City, IN
08-18-2020
Michigan City, Indiana
Technician Invoice Notes: Augered 3” Floor Sink Serving As Open Site Drain For One Hand Washing Sink And One Large Commercial Sink. Ran Large Amount Of Water While Augering To Clear Build Up Causing Slow Drain. Cleaned Debris Strainer And Grate Befor Re Installed. Tested Drain Operation And Observed No Back Up While Large Sink Discharged Full Load.
MICHIGAN CITY, IN
08-18-2020
Michigan City, Indiana
Call For Toilet Leaking Through: Replaced Fill Valve, Flapper And Supply Line For American Standard Toilet.
Michigan City, IN
03-23-2020