Gas Piping and Gas Piping Replacement

Dye Plumbing & Heatingstarstarstarstarstar5.0 / 5

5 stars
64
4 stars
1
3 stars
0
2 stars
0
1 stars
0

65 Total Reviews Dye Plumbing & Heating219-362-6251$1600 Lake Street, LaPorte IN

Gas Piping And Gas Piping Replacement Laporte, Indiana

Installation Natural Gas or LP fuel lines in Laporte, IN is our specialty. Call Dye Plumbing & Heating for your fuel and fuel service needs. Dye Plumbing & Heating is full licensed and insured to professionally install and pressure test your gas piping system to ensure trouble-free completion of your gas piping needs.

Get Your Quote Today



Dye Plumbing & Heating Gas Piping And Gas Piping Replacement Laporte, Indiana



Recent Gas Piping And Gas Piping Replacement Laporte, Indiana by Dye Plumbing & Heating

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Lav Drain To Be In Good Working Order. Inspected Tub Shower Drain And Found Overflow Stopper Stuck In Down Position. Disassembled Overflow And Removed Stopper. Observed Proper Flow Of Tub Drain At This Time . Informed Client Of Findings And Quoted New Waste And Overflow Due To No Stopper In Existing Overflow Anymore.
LAPORTE, IN
07-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For Poor Air Conditioning In The Main Area Of The Home. Upon Arrival Client Explained That Two New Air Conditioning Systems Had Recently Been Installed By A Different Company And The Master Bedroom System Seemed To Be Cooling Well. After Further Investigation Both New Systems To Be Sized Identically In Cooling Capacity. Found The Main Area Of The Home To Be Roughly 2000 Square Feet And The Equipment Undersized. Found Variable Speed Fan Selections For Both Pieces Of Equipment To Incorrect. Adjusted Master Bedroom System For Approximately 800 CFM Of Air And Did No Changes To The Main System Due To Its Lack Of Cooling Capacity. Also Found Kitchen/dining Room Zone Damper Failed. Client Requests Estimates For Replacement Air Conditioning Systems For Both Areas Of The Home. Client Will Receive The Proposals Via E-mail When Completed.
LaPorte, IN
07-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Leak On Copper Piping To Hot Side Of Washer Box. Removed Section And Replaced . Pressurized And Inspected Repair.
LAPORTE, IN
07-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Serviced Southern A/c System Per USP Plan Requirements. Inspected Blower Wheel, Evaporator Coil And Replaced Client Provided Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Ensured System Operates In Both Stages Of Cooling And Checked System Refrigerant Levels. Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LaPorte, IN
07-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For Poor Cooling. Upon Arrival Inspected All Indoor Airflow. Replaced Air Filter And Checked System Refrigerant Levels. Found Unit Low On R-22 Refrigerant. Added Up To 1# Of R-22 Refrigerant And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil. Client Plans To Replace The A/C System Next Season.
LAPORTE, IN
07-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Septic Tank Lid And Observed Blockage At Entry Point Of Septic. Informed Client Septic Is Full And Needs To Be Pumped In Order For Drainage To Work Correctly.
LaPorte, IN
07-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected All Indoor Airflow And Found Failed Dual Run Capacitor In Outdoor Condensing Unit. Replaced Capacitor And Checked Compressor And Fan Motor Amp Draws. Found Contactor Points Pitted And Charred; No Action Taken. Cycled System And Checked For Proper Refrigerant Levels. Unit Is Cooling Properly At This Time With A Temperature Drop Of 21 Degrees Across The Evaporator Coil.
LaPorte, IN
07-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Serviced Furnace And A/C Systems. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 78 Ohms, Cleaned Inducer Signal Port, Inspected Blower Wheel, Inspected Evaporator Coil And Replaced Air Filter. Also Inspected Primary Heat Exchanger Cells With No Failures At This Time. Found Inducer Motor With Noisy Bearings And Vent Piping Starting To Show Signs Of Fatigue. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 66°. Also Serviced A/C System. Inspected All Indoor Airflow, Water Washed Outdoor Condenser Coil And Replaced Failed Capacitor. Cycled System And Found Unit Low On R-22 Refrigerant. Added Up To 1# Of R-22 Refrigerant And Unit Is Cooling Properly With A Temperature Drop Of 16° Across The Evaporator Coil. Created An Estimate For A Replacement Inducer Motor And New Vent Piping. Client Would Like The Motor And Vent Piping To Be Replaced And An Appointment Made In The Fall. Client Would Like A Paper Receipt.
LaPorte, IN
07-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Investigated And Found Under Slab Sewer Line Obstruction Causing Backing Up. Camera Inspected And Found Soft Blockage In Piping. Augered Line To Clear Build Up.
LaPorte, IN
07-08-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Inspected Blower Wheel, Evaporator Coil And Air Filter. Test For Proper Airflow, Condensate Pump Cycled Properly During Visit. Water Washed Outdoor Condenser Coil, Tested All Electrical Components And Checked For Proper Charge Of System. System Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil.
LAPORTE, IN
07-07-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Callback For Water Around Furnace. Upon Arrival Removed Evaporator Coil And Cleaned All Remaining Water In And Around Drain Pan. After Further Investigation Found System Low On R-22 Refrigerant. Added Up To 1# Of R-22 And System Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil. Suspect System To Have Froze Due To Low Refrigerant And The Dirty Air Filter Removed On 6-30-20. The Remaining Condensate Water Beneath The Drain Pan Had Continued To Leak Onto The Floor In Conjunction With The Plugged Condensate Line Found On 6-30-20.
LAPORTE, IN
07-07-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Kitchen Faucet With New Customer Supplied Kitchen Faucet. Tested Operation Of Installation By Cycling Water Through Faucet And Checking For Leaks. No Issues At This Time.
LAPORTE, IN
07-02-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Failed Hose Faucet And Replaced With New Wolverine Brass Hose Faucet. Tested Operation Of Installation By Pressurizing, Checking For Leaks At Connections, And Cycling Faucet With No Issues At This Time.
LAPORTE, IN
07-02-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For No A/C In Bedroom Zone. Upon Arrival Found Outdoor Condenser Unit In To High Pressure Condition. After Further Investigation Found Failed Condenser Fan Motor. Replaced Condenser Fan Motor And Cycled Unit To Ensure Proper Operation. Unit Is Cooling Properly At This Time With A Temperature Drop Of 21 Degrees Across The Evaporator Coil.
LaPorte, IN
06-29-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Replaced Two Boiler Drains Serving Washing Machine.
LAPORTE, IN
06-29-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Turned Saddle Valve Off To Ice Maker In Basement. Unable To Test Due To Pets. Will Return On Later Date When Animals Are Secured. Upon Re Arrival Attached Existing Copper Line To Fridge. Tested Operation Of Shut Off Valve In Basement Found No Issues At This Time With Shut Off Valve Supplying Ice Maker Line. Tested Operation Of Attachment Of Ice Maker Line With No Leaks Or Issues At This Time.
LaPorte, IN
06-29-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Leak In Ceiling. Found Shower Drain Leaking When Used. Drywall Ceiling Damage Throughout Entirety Of Living Room And Portion Of Kitchen. Also Found Floor Damage From Where Leak Broke Through Ceiling And Seeped Into Basement Through Flooring. Informed Client Of Findings. Replaced 2” Shower Drain Along With 2” P Trap. Re Attached To Existing Pvc Piping. After Letting Glue Dry Tested Operation Of Repair By Cycling Large Amounts Of Water Through Shower With No Issues .
LaPorte, IN
06-29-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Performed USP A/C Service Per Plan Requirements , Checked Blower Wheel, Checked Evaporator Coil, Inspected Air Filter, Washed Outdoor Condenser Coil, Checked All Electrical Components, Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LAPORTE, IN
06-29-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Existing Washer Valves And Replaced With Two New Washer Valves. Tested Operation Of Installation By Pressurizing And Checking For Leaks With No Issues. Installed New Riser Pipe In L Type 1/2” Copper For Bathroom Tub Shower. Client Had Opened Wall Previous To Our Visit. Unable To Test Operation Of Installation Due To Client Not Having Tub Spout Or Trim Kit Installed At This Time.
LaPorte, IN
06-25-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes:Upon Arrival Found Hose Faucet Leaking At Handle And Into Home. Removed Section Of Drywall To Access Hose Faucet. Replaced With New Wolverine Brass Hose Faucet. Re Attached To Existing Copper Line. Re Pressurized Home And Tested Operation Of Installation By Cycling Water Through Hose Faucet With No Issues. Informed Client The Hose She Is Using Needs To Be Replaced As Well .
LaPorte, IN
06-25-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Cleaned Aerator On Customer Faucet Switched Hot And Cold Lines So That Hot Is On Left. Tested Operation Of Repair By Cycling Water With No Issues. Informed Client Of Broken Handle On Hot Side Stop Valve. Clients Did Not Want To Replace At This Time. Informed Client Of Where Whole House Water Shut Off Is Located.
LaPorte, IN
06-25-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Blower Wheel, Evaporator Coil And Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Cycled System From The Thermostat And Checked Unit Refrigerant Charge. Found System Low On R-22 Refrigerant. Client Declined Adding Refrigerant At This Time. Unit Is Operating At This Time With A Temperature Drop Of 14° Across The Evaporator Coil.
LAPORTE, IN
06-25-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Installed Client Provided Lavatory Cabinet And Top. Installed Client Provided Lavatory Faucet. Installed New Drainage And Supply To Faucet.
LaPorte, IN
06-24-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Fill Valve. Replaced Fill Valve And Supply Line Discounted Price Due To Flush Tower Being In Good Condition And Needing No Work Done. Tested Operation Of Installation By Cycling Toilet Multiple Times With No Issues.
LAPORTE, IN
06-22-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Investigated Leak Around Furnace And Found Condensate Line Unable To Drain Due To Minor Obstructions. Used Compressed Air To Clear Condensate Line. Tested Operation Of Repair By Cycling Water Through Line With No Issues.
LaPorte, IN
06-22-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Installed New 1” Blk Tee In Main Gas Line In Basement. Installed New 1” Gas Piping To Outdoors At Specified Location For Future Use. Capped Line And Pressurized. Leak Tested Fittings. Relocated Hose New Faucet To The Right Of Previous Location To Accommodate New Gas Meter. Pressurized And Inspected.
LaPorte, IN
06-22-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Installed New 1” Blk Tee In Main Gas Line In Basement. Installed New 1” Gas Piping To Outdoors At Specified Location For Future Use. Capped Line And Pressurized. Leak Tested Fittings. Relocated Hose New Faucet To The Right Of Previous Location To Accommodate New Gas Meter. Pressurized And Inspected.
LaPorte, IN
06-22-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Leak In Crawl Space When Lavatory Sink Ran. Found Failed 1 1/2” Copper Piping. Replaced Section With New 1 1/2” Pvc And Fittings. Attached Onto Existing Piping. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues.
LaPorte, IN
06-22-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Found Kitchen Sink Draining Slowly. Augered Out 30’ Multiple Times To Clear Food Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Hot Water With No Issues And Observing Proper Drainage At This Time.
LaPorte, IN
06-18-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Cycled Unit From The Thermostat And Checked System Refrigerant Charge. Unit Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil.
LaPorte, IN
06-18-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Failed Laundry Tub Faucet And Installed New Customer Supplied Delta Faucet With Spray. Tested Operation Of Installation By Cycling Water Through Appliance And Checking For Leaks. No Issues At This Time.
LaPorte, IN
06-17-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For Poor A/C. Upon Arrival Inspected Indoor Blower Wheel, Evaporator Coil And Replaced Air Filter. Inspected Outdoor Condensing Unit And Found Unit Low On R-22 Refrigerant. Added Up To 1# Of R-22 And System Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil. Recommend Having The Air Conditioning System Serviced Annually. Client Would Like A Paper Receipt.
LaPorte, IN
06-17-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call To Service Two A/C Systems And Diagnose Poor Cooling From Main System. Upon Arrival Inspected All Indoor Airflow. Inspected Blower Wheels, Evaporator Coils And Replaced Air Filters. Water Washed Outdoor Condenser Coils And Inspected All Electrical Components. Found Main System Dual Capacitor Weak Causing Outdoor Fan Motor To Short Cycle On Internal Overload. Also Found Bedroom System Capacitor Weak. Replaced Both Capacitors And Cycled Units To Ensure Proper Operation. Found Main System Low On R-22 Refrigerant. Added Up To 1# Of R-22 To Main System And Both Systems Are Cooling Properly At This Time With Temperature Drops Of 16° Across The Evaporator Coil.
LaPorte, IN
06-15-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Performed USP A/C Service. Inspected Blower Wheel, Evaporator Coil And Replaced Air Filter. Water Washed Condenser Coil And Inspected All Electrical Components. Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 18 Degrees Across The Evaporator Coil.
LaPorte, IN
06-15-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Toilet Bowl Full Of Waste Material. Augered With Toilet Auger To Clear Obstructions. Cleared Obstruction And Cycled Toilet To Test Operation.
LaPorte, IN
06-15-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For Water Leaking From Attic A/C System. Upon Arrival Found Condensate Pan Full And Condensate Piping Clogged. Cleared Drain Line And Inspected All Indoor Airflow. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Replaced Weak Dual Capacitor Per Clients Request. Checked System Refrigerant Levels And Added Up To 1# Of R-22 Refrigerant. System Is Cooling At This Time With A Temperature Drop Of 22 Degrees Across The Evaporator Coil. Recommend Replacing Pleated Air Filter With A Fiberglass Style Filter.
LaPorte, IN
06-12-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Replaced Water Heater Under Manufacturer Warranty. Installed New 3/4” Ball Valve Per Client Request. Filled And Cycled Unit. Set Temperature On Gas Control Valve To “hot” Setting. Model RG240T6N Serial TF43605947
LaPorte, IN
06-12-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Performed USP A/c Service Per Plan Requirements. Inspected Evaporator Coil, Blower Wheel And Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LaPorte, IN
06-12-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Installed Client Provided Toilet. Unable To Perform Lavatory Installation Due To Broken Top. Client Will Contact To Schedule Installation When New Top Acquired.
LaPorte, IN
06-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes:camera Inspected Line From Home To Yard Trap. Found No Root Intrusion And A Slight Soft Blockage. Augered Line Through Yard Trap To City Main. Removed Roots From Sewer
LaPorte, IN
06-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Echnician Invoice Notes: Upon Arrival Investigated Water In Crawl Space When Toilet Flushed And Found Failed 3” Copper Fitting Failed. Cut Out Failed Fitting And Replaced With New Pvc Fittings. Reattached To Existing Copper Drainage And Tested Operation By Cycling Toilet Multiple Times And Checking For Leaks With No Issues.
LaPorte, IN
06-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Our Ultimate Service Plan Includes Huge Discounts And Savings On All Of The Repairs And Installations That We Perform Every Day For Heating, Air Conditioning, And Plumbing. Whether It’s A New Enhancement Or Repair, We Have The Right Products And Solutions. As Part Of The Program, We Include Priority Service Guaranteed. Plus, You Can Save Even More During Business Hours.
LaPorte, IN
06-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Performed USP A\C Service Per Plan Requirements. Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Washable Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Cycled Unit And Checked System Refrigerant Charge. System Is Cooling Properly At This Time With A Temperature Drop Of 20° Across The Evaporator Coil.
LaPorte, IN
06-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Toilet Obstruction Causing Overflow. Augered Toilet And Cleared Obstruction. Tested Toilet Operation.
LaPorte, IN
06-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Well Tank Bladder Failed. Drained And Disposed Of Existing Tank . Installed New Well Mate 9 M:WM-9QUICKCONNECT S:070205288 Pressurized System And Tested Operation.
LaPorte, IN
06-09-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Client Water Heater With New Bradford White 50 Gal Standard Vent Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps. When Dreaming Water Heater Sump Pump Failed. Replaced Sump Pump With New Zoeller Sump Pump. Tested Operation Of Installation By Cycling Sump Pump Multiple Times With No Issues.
LaPorte, IN
06-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found Failed Blower Motor. After Further Investigation Found Blower Wheel Extremely Dirty And Air Filter Plugged. Replaced Client Provided Air Filter. Cleaned Blower Wheel, Replaced Blower Motor And Single Run Capacitor. Cycled Unit And Checked For Proper Refrigerant Levels. System Is Cooling Properly At This Time With A Temperature Drop Of 19 Degrees Across The Evaporator Coil.
LaPorte, IN
06-08-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes:Augered Lavatory Sink Drain. Filled Sink Twice To Test Drain Operation.
LaPorte, IN
06-08-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Sink Disposal Not Functioning Correctly. Reset Disposal And Used Allen Wrench To Break Free Build Up In Disposal. Tested Operation Of Repair By Cycling Disposal With Large Amounts Of Water With No Issues. Informed Client Of Findings And Age Of Disposal.
LaPorte, IN
06-05-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Broken Toilet And Replaced With Customer Supplied Eljer Toilet. Tested Operation Of Installation By Cycling Toilet Multiple Times. All In Good Order.
LaPorte, IN
06-05-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Broken Waste And Overflow, Client Also Wanted Shower Valve Replacement. Upon Further Investigation Of Access Panel Advised Client Much More Drywall And Part Of His Stairwell Ceiling Would Have To Be Removed In Order To Replace Shower Valve. Client Denied Shower Valve Replacement At This Time. Removed Copper Waste And Over Flow And Replaced With New Pvc Waste And Overflow. Tested Operation By Cycling Large Amounts Of Water While Observing Proper Flow With No Leaks.
LaPorte, IN
06-05-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Found Leaking Tub Faucet And Failed Tub Shoe. Replaced Delta Tub Faucet Cartridge With New Delta Tub Faucet Cartridge. Tested Operation Of Installation By Cycling Water And Testing For Drips. Replaced Waste And Overflow So Client Can Have Proper Tub Stopper. Tested Operation Of Installation By Cycling Water While Observing Proper Operation.
LaPorte, IN
06-05-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Blower Wheel, Inspected EAC And Inspected Evaporator Coil. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Replaced Capacitor Due To Weak Capacitance Measurements. Cycled Unit And Checked System Refrigerant Charge. Unit Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil.
LAPORTE, IN
06-05-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated Gas Smell. Leak Tested All Gas Piping Near Location Of Odor. Found Leak On 3/4” Union. Tightened Union And Re Inspected. Found No Other Leaks At This Time In Area.
LaPorte, IN
06-03-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated Gas Smell. Leak Tested All Gas Piping Near Location Of Odor. Found Leak On 3/4” Union. Tightened Union And Re Inspected. Found No Other Leaks At This Time In Area.
LaPorte, IN
06-03-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced 50 Gal Electric Water Heater With New Bradford White 40 Gal Electric Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
06-03-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Replaced Two Hose Faucets. Rebuilt Modern Leg Tub Faucet. Tested Repairs.
LaPorte, IN
05-28-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found High Pressure Switch Tripped. After Further Investigation Found Fan Speed Set Incorrectly And A/C System Overcharged. Re-adjusted Fan Speed And Removed Approximately Two Pounds Of Of R410-A Refrigerant. Cycled System To Ensure Proper Operation And Unit Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
LaPorte, IN
05-28-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected Blower Wheel, Evaporator Coil And Air Filter. After Further Investigation Found Failed Contactor In Outdoor Condenser. Replaced Contactor And Checked System Refrigerant Levels. Unit Is Cooling Properly At This Time With Drop Of 19 Degrees Across The Evaporator Coil. Recommended Considering Replacement Of The Air Conditioning System Due To Its Age.
LaPorte, IN
05-28-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Removed And Disposed Of Existing Water Heater. Installed New 40 Gallon Bradford White Water Heater With Atmospheric Vent. Model Number : RG240T6N Serial Number: TJ43914522 Filled Unit And Cycled. Set Temperature On Gas Control Valve To “hot” Setting. Checked Operation.
LaPorte, IN
05-27-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Found Failed Fan Capacitor On Outdoor Unit. Installed New Capacitor. Fan Motor Bearing Are Very Noisy. Compressor Is Very Noisy On Start Up And System Is Slightly Low On Refrigerant. Client Would Like Estimate To Replace The System.
LaPorte, IN
05-27-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Removed Existing Water Heater And Installed Client Supplied A.O. Smith 50 Gal Power Vent Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
05-26-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Toilet Unable To Flush Due To Sewage Line Holding Water, Found Water Heater Failed And Will Need 50 Gal Power Vent Bradford White Natural Gas Water Heater. Augered Sewage Line Out 10’ From Outside Clean Out To Clear Waste Paper, Baby Wipes And Waste Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Water. Installed New 50 Gal Power Vent Bradford White Water Heater . Attached To Existing Piping And Existing Re Circulation Line. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
05-26-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Existing Water Heater And Replaced With New Bradford White 50 Gal Standard Vent. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
05-26-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Unable To Re Create Gurgling In Kitchen Sink, Also Found Laundry Tub Holding Water When Laundry Machine Discharge Was In Use. Pulled 2” Clean Out Cap And Augered 30’ With D100 To Clear Line Obstructions. Kitchen Drainage Line Attaches To Laundry Discharge Line. Tested Operation Of Repair By Cycling Large Amounts Of Water Through Laundry Machine And Laundry Tub With No Issues At This Time.
LaPorte, IN
05-26-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Replaced Existing 30 Year Old Water Heater. Installed New Bradford White 40 Gallon Water Heater. Model Number RG240T6N Serial Number WC44871571. Filled And Cycled Unit. Set Temperature On Gas Control Valve To “hot” Setting. Inspected Operation.
LaPorte, IN
05-26-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Disposal Failed. Client Chose To Remove Unit And Have Basket Strainer Installed. Installed New Basket Strainer And Trap Assembly. Ran Water Nd Tested Operation.
LaPorte, IN
05-20-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Observed Lavatory Drain Holding Water. Disassembled And Attempted To Auger. 1 1/2” Galvanized Elbow Severely Rotted And Leaking. Replaced 2’ Section Of Galvanized Drainage Piping With New 1 1/2” Pvc Piping And Fittings. Augered Drain And Cleared Obstructions. Tested Operation Of Lav Drain By Cycling Large Amounts Of Hot Water With No Issues. Cleaned Hair Obstructions In Tub Drain And Tested Operation By Cycling Large Amounts Of Hot Water With No Issues.
LaPorte, IN
05-20-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Started A/C System As Part Of HVAC Contract Installation. Adjusted Indoor Blower Speed For 1000 CFM And Adjusted Refrigerant Charge With An Additional 10 OZ Of R-410A Refrigerant. Filled Condensate Pump To Ensure Proper Operation And System Is Cooling Properly With A Temperature Drop Of 16 Degrees Across The Evaporator Coil.
LaPorte, IN
05-20-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes:Call To Service A/C System. Inspected Blower Wheel, Inspected Evaporator Coil, Inspected Air Filter, Water Washed Outdoor Condenser Coil, Inspected All Electrical Components And Cycled System To Ensure Proper Operation. Inspected System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil. Client Would Like A Paper Receipt.
LaPorte, IN
05-20-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call To Service A/C System. Inspected Blower Wheel, Evaporator Coil And Replaced Client Supplied Air Filter. Water Outdoor Condenser Unit, Inspected All Electrical Components And Found Dual Capacitor Measuring Lower Than Factory Recommended Capacitance For The Outdoor Fan Motor. Client Declined Replacement Of The Capacitor At This Time. Cycled Unit, Measured All Amp Draws Within Specifications And Checked System Refrigerant Levels. Unit Is Operating Properly At This Time With A Temperature Drop Of 16 Degrees Across The Evaporator Coil.
LaPorte, IN
05-20-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Removed And Replaced Basket Strainer In Single Bay Hand Washing Sink. Replaced Safety Valve On Water Heater. Client Denied Full Flush And Tune So Adjusted Price Is Just For Replacement Of Safety Valve. Installed New Supplied ADA Round Bowl Toilet With Supplied Open Face Toilet Seat. Installed Repair Flange Before Setting Toilet. Will Return For Replacement Of Expansion Tank.
LaPorte, IN
05-20-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Septic Tank Operating Properly And Proper Flow To Tank. Investigated First Toilet And Observed Sluggish Flush. Augered Through Toilet And Still Observed Slow Flush. Suspect Trapway Obstructions Due To Large Amount Of Hardness Buildup In Bowl Into Trapway. Investigated Second Toilet And Found Broken Fill Valve Causing Water On Floor. Replaced Toilet Tank Components And Tested By Flushing Many Times.
LaPorte, IN
05-18-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Determined Sewer Obstruction Causing Backing Up Into Basement. Augered Main From Grease Trap To Yard Trap. Then From Yard Trap To City Main. Camera Inspected From Grease Trap To Yard Trap And Found Line Open And Operating. Unable To Camera Inspect Through Yard Trap.
LaPorte, IN
05-18-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Evaporator Coil, Replaced Client Supplied Air Filter, Inspected Blower Wheel, Water Washed Condenser Coil And Inspected All Electrical Components. Cycled Unit And Checked For Proper Refrigerant Levels. Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LaPorte, IN
05-18-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found 1/2” Galvanized Pipe Nipples Rusted At 1/2 X 3/8 Adaptation. Removed And Installed New Stop Valves To Eliminate Failed Piping.
LaPorte, IN
05-13-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Sewer System Not Draining. Augered Out 100’ To Clear Root Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues. Pulled And Reset Toilet By Kitchen To Access 3” Sewer Drainage Line.
LaPorte, IN
05-13-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Existing Hose Faucets (2), And Replaced With Two New Wolverine Brass Hose Faucets. Attached To Existing Piping And Tested Operation Of Installation By Cycling Both Hose Faucets.
LaPorte, IN
05-13-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Standing Water In 3” Clean Out. Augered Out 75’ To Clear Obstructions. Found Large Amount Of Root In 6” Clay Tile Sewage Line. Informed Client Of Proper Way To Take Care Of Situation By Installing Outdoor Clean Out. Ran Large Amounts Of Water To Inspect Operation Of Sewage Line. No Issues With Drainage At This Time. Inspected Back Flow Prevention Ball And Found In Good Condition. Clean Out Plug For Floor Drain Was Non Existent. Installed 1 1/2” Plug.
LaPorte, IN
05-13-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For No Heat From Boiler System. Upon Arrival Found Unit Displaying Fault Code F7 And Substantial System Pressure Difference Between Return And Supply Piping. After Further Investigation Found Domestic Recirculator Pump Partially Isolated Causing Inadequate Flow Through Heat Exchanger Assembly. Opened Valves And Cycled Boiler Through All Radiant Zones And Domestic Cycles. Unit Is Heating Properly At This Time And Cycles Off At 190° With A Pressure Of Approximately 21 PSIG.
LaPorte, IN
05-13-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Remove And Dispose Of Existing Cast Iron Bathtub And PVC Surround. Provide And Install: One Mustee 60
LaPorte, IN
05-11-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Lav Drain Plugged. Removed 4 Surgical Tools From P Trap And Augered Out 30’ To Clear Hair And Other Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Water While Observing Proper Drainage.
LaPorte, IN
05-11-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Removed Existing Silcock. Installed New Hose Faucet. Pressurized And Tested Installation.
LaPorte, IN
05-07-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Leaking At Base Of Toilet When Cycled. Pulled And Reset Toilet As Well As Tightening Fill Valve. Tested Operation Of Reset By Cycling Toilet Multiple Times To Check For Leaks. No Leaks At This Time. Added Pictures Of Main Cast Iron Drainage To Invoice For Possible Replacement If Issue Continues.
LaPorte, IN
05-07-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Replaced Previously Inspected Waste/overflow. Tested Operation.
LaPorte, IN
05-07-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Delta Single Handle Faucet Leaking When Used. Disassembled And Replaced Internal Components. Cleaned And Greased Friction Points And Seals. Tested Operation.
LaPorte, IN
05-07-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Tank To Bowl Basket And Pulled And Reset Water Closet. Tested Operation Of Repairs By Cycling Water Closet Multiple Times. Water Closet Cycling Correctly With No Leaks At This Time.
LaPorte, IN
05-07-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Replaced Freeze Damaged Hose Faucet. Pressurized And Tested Installation.
LaPorte, IN
04-30-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
GENERAL PLUMBING / PIPING REPAIR: Scope: Remove And Dispose Of Existing Double Vanity. Remove A Section Of Drywall As Needed To Access The Existing Supply And Drainage Piping. Provide And Install New Water Supply And Drain Lines As Needed To Supply The New Laundry Unit. Note: New Supply And Drain Piping Shall Be Mounted Exposed On The Interior Wall. Provide And Install One New 36
LaPorte, IN
04-30-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Grease Trap In Side Yard Full And Overflowing. Removed Water From Grease Trap And Observed Water Level In Neighboring Houses Grease Trap Dropping At Same Rate. Suspect Neighbor House Is On A Shared Sewer Line. Augered To Yard Trap To Clear Obstructions In Piping. Ran Large Amount Of Water And Ran Washing Machine To Test Flow.
LaPorte, IN
04-17-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Sink Faucet Leaking Large Amounts Of Water Into Cabinetry When Used. Informed Client Of Findings And To Give Us A Call When New Faucet Is Chosen For Installation.
LaPorte, IN
04-17-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
GENERAL PLUMBING / PIPING REPAIR: Scope: Remove And Dispose Of Existing Basement Drainage Piping. Provide And Install New PVC Drainage Piping And Fittings As Needed To Serve The First Floor Fixtures. Provide And Install A New Drain Tree Connection At The Existing Foundation Penetration. Provide And Install A New Waste & Overflow Assembly For The Existing Bathtub. Provide And Install A New 1-1/2 Inch Silent Check Valve For The Existing Sump Pump.
LaPorte, IN
04-15-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Moisture At Base Of Wall In Kitchen Behind Refrigerator. Camera Inspected Through Small Hole But Unable To Locate Source. Camera Inspected Through Shower Valve Hole In Second Floor Bath And In Joist Space Under Shower. Unable To Locate Source. Removed Sections Of Drywall Behind Refrigerator To Identify Location Of Leak. Due To A False Ceiling Unable To Make Repairs From Kitchen Side. Removed Section Of Wall In Shower Alcove On Opposite Side Of Wall To Expose 3/4” Copper Piping Failure Location. Removed Leaking Copper Tee And Surrounding Piping. Replaced With New Copper Piping And Fittings.
LaPorte, IN
04-11-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For Boiler Relief Valve Dripping. Upon Arrival Found Boiler Pressure At 20 PSIG And 180° With Evidence Of Relief Valve Leaking. Inspected Expansion Tank And Auto Fill Devices. Replaced Relief Valve And Purged Air From Boiler. Secured Bypass Handle Of Reducing Valve To Help Prevent The Possibility Of Accidental Over Pressurization Of The Boiler. Cycled Boiler To 180° And Found Unit Cycle Off At 19 PSIG. System Is Operating Properly At This Time With No Leaks Present.
LaPorte, IN
04-11-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Thermostat Calling For Heat With No Low Voltage. After Further Investigation Found Failed Transformer. Client Had Switched To A/C On The Thermostat Recently And The Furnace Never Came Back On. Found Rodent Chewed Wired At Outdoor Condenser. Repaired Low Voltage Wiring And Re-sealed Line Set Hole. Inspected Furnace Heat Exchanger And Found The Primary Cells Failed. Performed A Carbon Monoxide Test And Unit Is Emitting No Carbon Monoxide At This Time. Highly Recommended Client To Replace Furnace Due To The Potential For Carbon Monoxide Gases.
LaPorte, IN
04-11-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Basement Toilet To Have A Broken Fill Valve. Replaced Toilet Tank Components. Set Proper Water Level And Cycled To Test Operation.
LaPorte, IN
04-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Call For Main Circulator Pump Leaking. Upon Arrival Found Failed Bearing Assembly In Main B&G Pump. Replaced Pump Assembly With New Taco Circulator And Cycled Boiler To Ensure Proper Operation. System Is Heating Properly At This Time. Recommend Having The Other Two Circulator Pumps Replaced Due To Noisy Operation And Having Boiler Serviced Annually For Preventative Maintenance Purposes.
LaPorte, IN
04-10-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Observed No Flow At Yard Trap In Front Yard. Augered From Yard Trap To Main With 2.5” Blade And Cleared Root And Wipe Obstructions. Pulled Main Toilet And Augered With 3” Blade To Yard Trap And Removed Large Amounts Of Root And Wipes. Attempted To Auger From Yard Trap To Main With 3” Blade. Unable To Auger With 3” Due To Separations In Piping. Tested Laundry Drain With Large Amounts Of Water. Observed Proper Drainage At Laundry Drain And Observed Flow From Yard Trap When Cycling Toilet And Laundry. Informed Client Of Findings.
LaPorte, IN
04-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Hooked Up Customer Stove And Tested For Proper Operation And Gas Leaks. No Gas Leaks And Proper Operation Of Stove At This Time.
LaPorte, IN
04-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Hooked Up Customer Stove And Tested For Proper Operation And Gas Leaks. No Gas Leaks And Proper Operation Of Stove At This Time.
LaPorte, IN
04-09-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
WELL MATE 9 PRESSURE TANK INCLUDES FITTINGS AND GAUGE: Provide And Install A New Well Mate 9 Pressure Tank With Near Piping, Relief Valve And Pressure Gauge.
LaPorte, IN
04-03-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed Client Supplied Water Closet And Removed Existing. Tested Operation By Cycling Water Closet Multiple Times.
LaPorte, IN
04-03-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Upon Arrival Observed Outdoor Clean Out With Standing Water. When Appliances Ran Overflow At The Laundry Drain In Basement Would Occur. Augered Out Of Main Clean 30’ Multiple Times To Clear Obstructions. Attempted To Camera Line But Unable To Due To Large Separation At Clean Out Tee. Observed Good Flow At This Time When Toilets Flushed.
LaPorte, IN
04-02-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Investigated And Found Pressure Assisted Toilet Tank Bladder Leaking At Seam Into Tank. Removed And Replaced Failed Tank. Cycled And Tested Operation.
LaPorte, IN
04-02-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Gfi Tripped For Disposal. Reset And Found Garbage Disposal To Be Working At This Time With No Issues. Client Would Not Like Installation Of New Disposer.
LaPorte, IN
04-02-2020

starstarstarstarstar
5 Star Rating
Gas Piping And Gas Piping Replacement Laporte, Indiana
Technician Invoice Notes: Installed New A95UH1E070B12 Armstrong Furnace, Honeywell Focus Pro 6000 Programmable Thermostat And Reme Halo LED Air Purifier Per HVAC Contract Details. Tested System Operation And Unit Is Operating Properly With A Temperature Rise Of 54°. InstlDtL Installation Details: EQUIPMENT > Armstrong High Efficiency Furnace Model A95UH1E070B12S-06 - 95% AFUE Efficiency Rating > Honeywell Focus Pro 5000 Non-programmable Thermostat SCOPE OF WORK 1. Remove And Dispose Of The Existing Furnace. 2. Install The New Furnace, Adapting To The Existing Supply And Return Air Duct Systems. 3. Connect The Furnace To The Existing Electrical Circuit, Exhaust Piping And Gas Piping. - Repair Leaking Exhaust PVC Elbow 4. Install A New Honeywell Focus Pro 5000 Thermostat In The Same Location As The Existing Thermostat. 5. Start The New Furnace And Check System Operation. Factory Warranties: All Equipment Warranties Per The Terms And Conditions Of The Manufacturer. Armstrong Equipment For This Application Qualifies For A Ten Year Limited Parts Warranty With A Limited Lifetime Parts Warranty On The Heat Exchanger. Please Review All Manufacturer Warranty Certificates For Full Details Of Warranties. Dye Plumbing & Heating Warranty: We Offer A Two Year Material And Labor Warranty For The Work Provided. This Warranty Does Not Include Standard Maintenance Procedures (annual Cleaning, Filter Changes, Etc.)
LaPorte, IN
04-01-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Installation Details:EQUIPMENT:Armstrong Model: A96UH2E070B12S-01; Serial: 5919M00951 Series High Efficiency Furnace- 96% AFUE Efficiency Rating- Two Stage Operation- Stainless Steel Heat Exchangers- ECM Constant Torque Blower MotorSCOPE OF WORK:1.Remove And Dispose Of The Existing Furnace And Condensate Drain Piping.2.Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work. 3.Adapt The New Furnace To The Existing Line Voltage And Low Voltage Electrical Circuits.4. Adapt The New Furnace To The Existing Gas Supply Piping.5. Adapt The New Furnace To The Existing PVC Intake & Exhaust Vent Piping. - Terminate The Exhaust Piping Per Manufactures Instructions.6. Provide And Install New Condensate Drainage Piping From The New Furnace And Existing A/C Evaporator Coil.7. Adapt The New Furnace To The Existing Thermostat.8. Start The New Equipment And Check System Operation. - Ensure Proper Airflow Selections Have Been Made For The Cooling And Heating Cycles Of The Equipment.All Equipment Warranties Per The Terms And Conditions Of The Manufacturer. Armstrong Equipment For This Application Qualifies For A Ten Year Limited Parts Warranty With A Standard Twenty Year Parts Warranty On The Heat Exchangers. Please Review All Manufacturer Warranty Certificates For Full Details Of Warranties.Dye Plumbing & Heating Warranty: We Offer A Two Year Material And Labor Warranty For The Work Provided. This Warranty Does Not Include Standard Maintenance Procedures (annual Cleaning, Filter Changes, Etc).
LaPorte, IN
04-01-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Investigated And Found Handle On Zurn Flushometer Sticking In Downward Position. Replaced Handle Assembly And Tested Operation. Inspected Two Toilets In Same Rest Room. Found Middle Toilet Leaking A Large Amount Of Water When Cycled From Vacuum Breaker. Replaced Failed Component And Tested.
LaPorte, IN
04-01-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Investigated Well Operation And Found Well Cycling Properly Between 30/50 Psi. Investigated Incoming Water Piping. Found Whole House Filter. Removed And Observed Filter To Be Clogged. Client Would Like To Have Softener Company Replace Filter. Left Filter Out Of Housing And Inspected Pressure. Found Much Better Pressure At Fixtures.
LaPorte, IN
04-01-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Upon Arrival Observed Whole House Plumbing System Backing Up. Checked Septic To See If Needed Pumped. Once Back Indoors Whole House Plumbing System Drained And Siphoned All Traps Dry. Flushed Toilet And Observed Proper Function With Leak Around Base. Pulled Toilet To Reset And Cameraed Line As Well. Observed No Obstructions. Reset Toilet And Tested Along With All Fixtures, Draining Properly At This Time.
LaPorte, IN
04-01-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Upon Arrival Found Main Water Closet Unable To Flush. Used Toilet Auger To Clear Trap Way Multiple Times To Remove Obstructions. Tested Operation By Cycling Water Closet Multiple Times.
LaPorte, IN
04-01-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Call To Replace Customer Provided Sump Pump. Replaced Client Provided 3/4 Hp Sump Pump Replaced Check Valve And Near Piping. Tested New Pump For Proper Operation. Pump Is Operating Properly At This Time.
LaPorte, IN
03-31-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Upon Arrival Found Kitchen Sink Not Draining Properly. Ran Auger Out 30’ Multiple Times To Clear Obstructions. Tested Operation By Cycling Large Amounts Of Hot Water With No Issues Draining At This Time. Unable To Input Card Will Call For Payment. Client Would Like Mailed Receipt.
LAPORTE, IN
03-31-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
INSTALLED NEW WATER SUPPLY, DRAINAGE PIPING, GAS PIPING AND DRYER VENT TO MOVE WASHER AND DRYER UPSTAIRS FROM BASEMENT.
LaPorte, IN
03-28-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
INSTALLED NEW WATER SUPPLY, DRAINAGE PIPING, GAS PIPING AND DRYER VENT TO MOVE WASHER AND DRYER UPSTAIRS FROM BASEMENT.
LaPorte, IN
03-28-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Call For No Heat. Upon Arrival Found Furnace In Lockout Due To Pressure Switch Fault. After Further Investigation Found Condensate Drain Line Plugged Leading To Sump Pit. Cleared All Drains And Inspected Heat Exchangers. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 69 Degrees.
LaPorte, IN
03-28-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Upon Arrival Observed Standing Water In Outdoor Cleanout. Augered 50’ To City Main And 25’ Towards Home Multiple Times To Clear Obstructions. Found Severe Separation At Cleanout Connection To Clay Tile And Numerous More From Cleanout To Main Sewer. Observed Proper Flow At This Time.
LaPorte, IN
03-28-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Upon Arrival Found Flapper In Employee Bathroom And Customer Bathroom Leaking Through. Changed Flappers And Tested Operation By Cycling Water Closets Multiple Times. Found No Drips, Leaks, Or Issues With Any Other Fixtures Or Flushometers.
LaPorte, IN
03-26-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Call For No Heat. Upon Arrival Found Boiler System With No Pressure And Not Operating. Pressurized Boiler And Boiler System Piping. Could Not Determine Any Leaks At This Time. After Further Investigation Found Failed Roll-out Safety Switch. Found Chimney Clean Out Cover Forced Open From Chimney Debri Which Allowed Boiler To Vent Into The Home And Burn Incorrectly. Boiler Sections Are Sooted To The Point Of Boiler Failure. Gathered Information To Provide An Estimate For A Replacement Boiler System. Client Will Receive The Estimate Via Email When Completed. Left Power To Wi-if Thermostat On For Remote Temperature Monitoring.
LaPorte, IN
03-26-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Investigated And Found Client Had Just Done Laundry. Found Sump Pump Plugged Into A Non Grounded Extension Cord. Unplugged From Extension Cord And Plugged Directly Into Outlet. Pump Functioning Properly And Expelled Entire Pit Content. Augered Lavatory Sink Drain Line. Found Line Sludgy. Ran Large Amount Of Water After Augered. Lavatory Draining Proper At This Time. Recommend Dedicating An Outlet To Serve Sump Pump.
LaPorte, IN
03-24-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Upon Arrival Found Kitchen Sink With Standing Water In Drain. Augered Kitchen Sink Drain. Reassembled Trap Way And Ran Large Amount Of Water To Flush Line And Test Operation. Observed Proper Flow.
LAPORTE, IN
03-23-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Located Underground Sewer Piping Near House Outdoors. Excavated Area And Unearthed Pipe. Found Cast Iron Separation Near Foundation. Removed Section Of Disjointed Piping To Area With Proper Pitch. Installed New 4” Pvc Piping And Clean Out. Flushed Toilet And Ran Water In Fixtures. Observed Proper Flow Through Repaired Piping. Backfilled Site And Bedded Piping.
Laporte, IN
03-23-2020

Gas Piping And Gas Piping Replacement Laporte, Indiana
Performed Water Heater Flush And Cleaned Combustion Components. Install One New Full Port Brass Ball Valve For Future Maintenance.
LaPorte, IN
03-17-2020

©MPN Media & Marketing 2020