Air Conditioning Service, Repair and Installation

Dye Plumbing & Heatingstarstarstarstarstar4.9 / 5

269 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Air Conditioning Service, Repair And Installation La Porte, Indiana

Dye Plumbing & Heating is one of the leading providers of air conditioning repair and air conditioning service in La Porte, IN, offering timely solutions to problems related to your air conditioning system. Our HVAC technicians will come to your rescue when you want emergency AC service or repair, or just need a hand with your residential or commercial cooling problems.

You'll find we take our job seriously and highly value the trust that is placed in us. Dye Plumbing & Heating goes far beyond what others do by investing in the training and equipment necessary to protect your home or family in La Porte, IN. Whether you have a central AC system, Heat Pump or Ductless Mini Split we are here to help.

Get Your Quote Today



Dye Plumbing & Heating Air Conditioning Service, Repair And Installation La Porte, Indiana



Recent Air Conditioning Service, Repair And Installation La Porte, Indiana by Dye Plumbing & Heating

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No A/c And Thermostat Not Working. Found Furnace Breaker Tripped. Upon Further Investigation Found Water Leaking Onto Junction Box Causing Breaker To Trip.
La Porte, IN
07-21-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No A/C On First Floor. Upon Arrival Found Air Filter Plugged And Blower Wheel Slightly Dirty. Inspected Evaporator Coil And Found System Low On Refrigerant. Added Three Pounds Of R-22 Refrigerant, Replaced Client Provided Air Filter And Unit Is Cooling Properly At This Time With A Temperature Drop Of 19 Degrees Across The Evaporator Coil. Also Inspected Second Floor A/C Systems Per Clients Request. Replaced Client Provided Air Filters And Ensured Units Are Operating Properly. Replaced Batteries In Master Bedroom Thermostat. All Units Are Cooling At This Time And Set To 75°.
La Porte, IN
07-14-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No A/c. Upon Arrival Found Failed Dual Capacitor. Customer Opted To Replace Capacitor. After Further Investigation Found System Low On Refrigerant. Customer Opted To Have System Recharged. Added 1# 410 A To System. Cycled System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
La Porte, IN
07-14-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No A/c. Upon Arrival Found Failed Dual Capacitor. Replaced Capacitor Per Customer Request. After Further Investigation Found System Low On Refrigerant. Added Up To 1# R22 Per Customer Request. Cycled System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
La Porte, IN
07-08-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For A/c Making Strange Noise (at The Furnace). After Further Investigation Found Evaporator Coil Slightly Obstructed With Ice Causing Airflow To Make Strange Sound. Allowed Evaporator Coil To Thaw. Customer Opted To Have System Recharged. Added 1# R22 To System. Cyc System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil. Explained To Customer There May Be A Slow Leak In System And We Will Know More Info Next Spring When We Return To Service.
La Porte, IN
07-08-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found Failed Contactor Due To Earwig. Replaced Contactor And Checked System Refrigerant Charge. System Is Cooling Properly At This Time With A Temperature Drop Of 16 Degrees Across The Evaporator Coil.
La Porte, IN
07-08-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No A/C. Found Programmable Thermostat Malfunctioning, Replaced Thermostat With Customer Supplied Thermostat. Showed Customer How To Work New Thermostat. Cycled System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 20°.
La Porte, IN
06-15-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No A/c. Upon Arrival Found Failed Capacitor And Failed Breaker In Disconnect. Replaced Disconnect And Tested System. System Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
La Porte, IN
06-15-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: No AC. Upon Arrival Inspected Evaporator Coil To See If Frozen - Is Not. Investigated To Find Low System Charge. Charged System With 1# 14oz Of R410. System Is Now Cooling Properly With A Temperature Drop Of 17 Degrees.
La Porte, IN
06-03-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For No AC/foyer Not Cool Enough. Inspected Evaporator Coil, Air Filters And Condensate Drain And Blower Wheel. Replaced CP Air Filter, Ran Static Pressure Test: .3 Took Apart Condenser To Water Wash Condensing Coil Which Was Plugged With Cottonwood. Checked Refrigerant Levels Which Are Ok And Unit Is Cooling Properly With A Temperature Drop Of 17 Degrees. Advised Customer To Add Blinds Or Tint To Foyer Windows To Mitigate The Sun Through The Windows.
La Porte, IN
05-27-2021

Air Conditioning Service, Repair And Installation La Porte, Indiana
Notes: Serve And Clean AC. Inspected Evaporator Coil, Blower Wheel, Replaced CP Air Filter And Condensate Drain. Inspected Condensing Coil And Checked All Electrical Components. Replaced Weak Testing Capacitor. System Refrigerant Levels Are Ok And Unit Is Cooling Properly With A Temperature Drop Of 19 Degrees.
La Porte, IN
05-27-2021

star
1 Star Rating
Air Conditioning Service, Repair And Installation La Porte, Indiana
Technician Invoice Notes: Call For Main Floor AC Not Cooling Properly. Inspected Data Tags To See If Coils Match. Inspected Evaporator Coil, Performed Static Pressure Test On Wet Coil - Is High At 1 IWC. Moved Cooling Blower Tap From ‘A’ To ‘B’ - Got Static Down To .6 IWC. Checked Refrigerant Levels And Is Low. Added 3# 9oz. Unit Is Cooling Properly With A Temperature Drop Of 18 Degrees. Need To Schedule A Freon Leak Test For Main Level AC. Checked Refrigerant Levels In Basement AC. Levels Are Ok And Unit Is Cooling Properly With A Temperature Drop Of 20 Degrees.
La Porte, IN
05-27-2021