If you are looking for a luxurious new installation, or need help with your existing kitchen or bath, At Dye Plumbing & Heating we're Here to help. We have licensed and insured plumbers to get your work done. For your bathroom, we offer toilet repair and replacement, showers and tubs, sinks, and laundry room hookups. For your kitchen, we offer sinks, ice-maker and dishwasher installations, garbage disposals and faucets.

Get Your Quote Today



Dye Plumbing & Heating La Porte, Indiana



Recent La Porte, Indiana by Dye Plumbing & Heating

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Large Amounts Of Debris In Shower Head Screens Causing Low Pressure In Downstairs Shower. Removed Screens And Observed Proper Pressure At This Time. Also Found Sewage Ejection Pump With Suspected Debris On Float. Observed Proper Operation Of Sewage Ejection Pump Several Times Before Informing Client Of Age Of Pump And That We Can Replace. Client Denied At This Time.
La Porte, IN
07-21-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Inspected Toilet With Poor Flush And Found 1.28 Gal Toilet Cycling Correctly When Flushed Correctly. If Toilet Handle Is Pressed Lightly Only Half Flush Occurs. Informed Client Of Findings. Also Conducted Flush And Tune On Navien Tankless Water Heater. Post Flush And Tune Tested Operation Of Water Heater By Cycling Hot Side Of Faucets With No Issues At This Time.
La Porte, IN
07-21-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Garbage Disposal And Basket Strainer. Removed Garbage Disposal And Adjacent Basket Strainer. Installed Two New Basket Strainers Along With New Continuous Waste End Outlet Attaching Onto Existing 1 1/2” Pvc . Used Wire Nuts And Electrical Tape To Cover Old Garbage Disposal Wireing, Informed Client That Electrician Will Be Necessary If Old Wiring Is To Be Removed Completely. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues At This Time.
La Porte, IN
07-02-2021

starstarstarstarstar
5 Star Rating
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Conducted Pull And Reset On Toilet Leaking Around Base Minimally. Also Replaced Seats And Springs On Single Handle Delta Lav Faucet. Tested Operation Of Both Repairs By Cycling Water Through Fixtures While Observing Proper Operation. Informed Client Of Findings . No Leaks Or Issues At This Time.
La Porte, IN
06-21-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Metal Nut Attaching Tubular Direct Connect To Basket Strainer. Replaced With New Nut And Washer And Tested. Found No Issues With New Nut And Washer But Did Find Basket Strainer Leaking Slowly. Informed Client Of Findings. Client Is Going To Have Sink Replaced Soon And Isn’t Worried About The Slow Drip. Client Will Call Us Back For New Sink Installation.
La Porte, IN
06-03-2021

La Porte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Found Lav Aerator On Delta Faucet Plugged With Limescale Build Up . Removed And Cleaned. Re Assembled And Observed Proper Pressure To Faucet At This Time. Also Discussed Bidet Seat Leaking Into Bowl After Usage . Informed Client Some Seats Purge Them Selves After Use. Also Looked At Water Marks Around Ceiling Vent That Was Closed. Informed Client The Minimal Water Markings Could Be Moisture Build Up Due To Vent Always Being Closed. Cracked Vent And Informed Client Of Why To Keep Vent At Least Cracked. No Other Issues At This Time.
La Porte, IN
05-27-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Conducted Repairs Requested By Home Inspector. Replaced 1/2” Gas Cock And Added Drip Leg. Installed Discharge Tube For T P Valve On Water Heater. Removed Female Thread Cap After Ball Valve And Used Leak Lock To Properly Seal Cap. Also Re Assembled Shower Cartridge. Tested Operation Of Gas Repairs By Spraying New Joints With No Gas Leaks Or Issues. Also Pressurized Home And Tested Shower Valve By Cycling Large Amounts Of Water With No More Dripping Or Issues At This Time With The Capped Line Or Shower Valve. All Issues Requested By Client Per Inspector Have Been Taken Care Of.
La Porte, IN
05-27-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found All Valves In Laundry Room In Good Working Order. Client Did Not Want To Replace Any Valves Unless Neccesary. Also Removed Kitchen Sink Faucet And Attempted To Install Customer Supplied With The Inability To Due So Due To Center Mounting Male Fitting Being To Large For Sink Holes. Attempted To Install 400 Dst And Found Kitchen Sink Has A 6” Spread With A 4th Hole For Hand Spray. Informed Client We Will Attempt To Find A Replacement Kitchen Faucet That Is Similar In Style To The 400dst With A 6” Spread.
La Porte, IN
05-24-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Kohler Shower Valve Only Producing Cold Water. Shut Water Off To Home And Disassembled Shower Valve In Order To Take Pictures Of The Cartridge To Order. Informed Client We Will Order A New Shower Cartridge And Call To Re Schedule. No Other Issues At This Time.
La Porte, IN
04-28-2021

La Porte, Indiana
Uponnarrival Used Hand Auger To Auger Toilet. Augered Multiple Times Clearing Waste And Paper Obstructions. Tested Operation Of Repair By Cycling Toilet Multiple Times With No Issues. Informed Client Age Of Toilet And If Issues Continue New Toilet May Be Necessary.
La Porte, IN
03-25-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Disposal Not Working And Kitchen Faucet With Low Pressure To Both Hot And Cold Side. Removed Faucet Head And Cleaned Aerators And Screens. Removed Large Amounts Of Debris. Re Assembled And Tested With Proper Pressure To Now Both Hot And Cold Side. Reset Limit Switch On Disposal As Well As Unjammimg With Allen Wrench. Cycled Large Amounts Of Water With Proper Operation And No Leaks Or Issues. Informed Client Of Age Of Disposal. Client Denied Replacement At This Time.
La Porte, IN
03-25-2021

La Porte, Indiana
Technician Invoice Notes: Upon Arrival Installed New Tee Attachment For Existing Hot Side Stop Valve And New Stop Valve For Dishwasher Supply Attachment. No Issues At This Time.
La Porte, IN
03-19-2021