La Porte, Indiana
Uponnarrival Used Hand Auger To Auger Toilet. Augered Multiple Times Clearing Waste And Paper Obstructions. Tested Operation Of Repair By Cycling Toilet Multiple Times With No Issues. Informed Client Age Of Toilet And If Issues Continue New Toilet May Be Necessary.
La Porte, IN
03-25-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Disposal Not Working And Kitchen Faucet With Low Pressure To Both Hot And Cold Side. Removed Faucet Head And Cleaned Aerators And Screens. Removed Large Amounts Of Debris. Re Assembled And Tested With Proper Pressure To Now Both Hot And Cold Side. Reset Limit Switch On Disposal As Well As Unjammimg With Allen Wrench. Cycled Large Amounts Of Water With Proper Operation And No Leaks Or Issues. Informed Client Of Age Of Disposal. Client Denied Replacement At This Time.
La Porte, IN
03-25-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Installed New Tee Attachment For Existing Hot Side Stop Valve And New Stop Valve For Dishwasher Supply Attachment. No Issues At This Time.
La Porte, IN
03-19-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Faucet Spray Handle Leaking Into Cabinetry. Attempted To Replace Only Spray Handle And Line With No Success. Replaced Kitchen Faucet With New Delta Single Handle Faucet With Sprayer. Tested Operation Of Repair By Cycling Faucet With No Issues. Also Found Kitchen Faucet In Bathroom Leaking At Spout. Disassembled Spout And Replaced O Rings. Re Assembled And Tested With No Issues Or Leaks At This Time .
La Porte, IN
03-09-2021
La Porte, Indiana
Technician Invoice Notes: Uponnarrival Removed Failed Copper Waste And Overflow, Drum Trap, And Minimal 1 1/2” Copper Piping. Installed New Pvc Glue Waste And Overflow Along With New Glue P Trap Attaching Onto Existing Good Portion Of Copper Drainage. Tested Operation Of Installation By Cycling Large Amounts Of Water With No Issues At This Time.
La Porte, IN
02-26-2021
La Porte, Indiana
Technician Invoice Notes: Extracted Moen Positemp Tub/shower Valve Cartridge.
Earned And Greased Valve Body. Installed New Cartridge. Installed Trim And Tested Operation.
La Porte, IN
02-23-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Waste And Overflow, 1 1/2” Galvanized Drum Trap, And 10’ Of Galvanized Piping Needing Replaced. Replaced Waste And Overflow With New Glue Waste And Overflow And Glue P Trap. Replaced Gaivanized Piping With New 1 1/2” Pvc Piping And Necessary Fittings. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues At This Time. Also Observed Large Cracks In Tub Previous To Repair. Informed Client Of Findings.
La Porte, IN
02-15-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Single Handle Delta Tub Shower Faucet With Very Low Pressure, Removed Cartridge And Cycled Large Amounts Of Water To Attempt And Blow Out Build Up. Observed Only Hot Side In Shower Valve Allowing Water Through. Upon Further Investigation In Crawl Space/basement, Found Gaps In Foundation Underneath Deck Allowing Cold Air Into Crawl Space/basement. Shower Cpvc Piping Is Closest To Cold Air Entering Space. Informed Client Of Possible Freezing Piping. Installed New Cartridge And Tested While Still Observing Low Flow. Informed Client Of Possible Freezing Piping And To Repair Holes In Entrances To Crawl Space/ Basement To Mitigate And Further Issues. Also Informed Client Of Dangers With The Improper Venting On Water Heater. Told Client To Purchase Co Detectors And Water Heater Should Be Shut Off And Powervent Installed As Soon As Possible. Provided Estimate For New Powervent Installation.
La Porte, IN
02-11-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Waste And Overflow Leaking When Water Ran Along With Failed Drum Trap. Removed And Installed New Glue Waste And Overflow Along With New 1 1/2” Glue P Trap. Used Necessary 1 1/2” Pvc And Pvc Fittings To Attach Onto 1 1/2” Galvanized Drainage And 1 1/2” Venting. When Venting Was Cut And Disconnected Found Venting Wanting To Fall From Roof Downward. Supported Venting With Steel Strap. Installed 1 1/2” Wye Clean Out With New Drainage. When Cycling Water Not Used Tub Holding Water. Used Drill Auger To Auger 25’ To Clear Obstructions. Tested Repair And Installation By Cycling Large Amounts Of Water With No Issues. Informed Client Of Silicone And Proper Cure Time.
La Porte, IN
01-30-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Leak Underneath Whirlpool Jetted Tub. Had Good Visual Access To Drainage In Basement. Cycled Tub While Observing For Leaks And Found No Signs Of Leaking Or Current Leaking At This Time. Had Client Fill Tub To Jet Height And Cycle Jets. No Leaking At This Time From Jets , But When Water Was Leaking It Was Soaking Installation Around Drainage And Dripping Onto Floor. All Grout Lines Appear To Be In Good Shape, Splashed Water Around Tub To Double Check. Found No Leaks Or Issues From Splashing Outside Of Tub. Informed Client The Problem Is More Than Likely Is An Intermittent Leak With The Jett System And To Contact A Company Who Works On Whirlpool Style Tubs.
La Porte, IN
01-25-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Removed Section Of Improper Drainage Piping And Replaced With Assortment Of 2” And 1 1/2” New Pvc Fittings And Piping. Tested Operation Of Repair By Cycling Water With No Issues At This Time .
La Porte, IN
01-15-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found One Kitchen Faucet And One Laundry Tub Faucet With Low Pressure . Dissasembled, Removed Debris Screens , And Cleaned Out Large Amounts Of Debris. Re Assembled And Tested With Proper Pressure To Both Faucets . Discussed Galvanized Piping Issues With Client.
La Porte, IN
01-07-2021
La Porte, Indiana
Technician Invoice Notes: Inspected And Found Internal Components Failed Causing Water To Seep Into Bowl Continuously. Replaced Cartridge And Air Admitting Valve. Cycled Many Times To Adjust Cartridge Depth And Then Test Operation.
La Porte, IN
01-04-2021