Technician Invoice Notes: Performed Furnace Service. Cleaned Burners, Crossovers And Flame Sensor. Inspected Heat Exchanger And Blower. Igniter 87 Ohms. Cycled Unit And Tested Operation. Unit Heating Properly At This Time With A Temperature Rise Of 59°
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Performed Furnace Service. Cleaned Burners, Crossovers And Flame Sensor. Inspected Heat Exchanger And Blower. Igniter Resistance 75 Ohms. Cycled Unit And Tested Operation. Unit Heating Properly At This Time With A Temperature Rise Of 67°.
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Performed Furnace Service. Cleaned Burners, Crossovers And Flame Sensor. Igniter 67ohms. Inspected Heat Exchanger And Blower. Inducer Motor Noisy. Cycled Unit And Tested Operation. Unit Heating Properly At This Time With A Temperature Rise Of 57°
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Cleaned Burners, Cleaned Flame Sensor, Cleaned Inducer Signal Port, Ignitor 69 Ohms, Inspected Air Filter, Inspected Blower Wheel And Inspected Primary Heat Exchanger Cells. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 72° Degrees.
Kingsford Heights, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Serviced Furnace. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 85 Ohms, Inspected Blower Wheel, Inspected Air Filter, Cleaned Inducer Signal Port And Inspected Primary Heat Exchanger Cells. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 73°.
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Note: Serviced Furnace. Measured Igniter Resistance At 50 Ohms, Cleaned Inducer Signal Port, Inspected Blower Wheel, Inspected Air Filter. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 60 Degrees.
Kingsford Heights, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 85 Ohms, Inspected Blower Wheel, Cleaned Inducer Signal. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 69°. Also Found Inducer Motor Bearings Slightly Noisy.
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes. Performed Furnace Service . Cleaned Burners, And Flame Sensor. Checked Blower And Heat Exchanger. Ignitor At 92 Ohms; Recommended Replacing Ignitor. Cycled Unit And Tested Operation. Unit Heating Properly At This Time, Heat Rise Of 69°.
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice. Performed Furnace Service . Cleaned Burners, Crossovers, Replaced Broken Flame Sensor, And Swept Vent. Checked Blower And Heat Exchanger. Ignitor At 82ohms. Cycled Unit And Tested Operation. Unit Heating Properly At This Time With A Temperature Rise Of 72°. Tenant Has Several Registers Blocked With Furniture Causing A High Temperature Rise.
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Serviced Furnace. Inspected Heat Exchanger Assembly With No Failures At This Time. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 79 Ohms, Swept Vent And Inducer Assembly, Cleaned Inducer Signal Port And Cycled Unit To Ensure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 53°
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Serviced Furnace. Inspected Heat Exchanger Assembly With No Failures At This Time. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 79 Ohms, Swept Vent And Inducer Assembly, Cleaned Inducer Signal Port And Cycled Unit To Ensure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 64°. Suspect Inducer Motor Bearings Are Failing.
KINGSFORD HEIGHTS, IN
08-20-2020

Kingsford Heights, Indiana
Technician Invoice Notes: Upon Arrival Removed Failed Section Of Copper 3/4” Piping. Installed New L Type Copper And Proper Fittings. Tested Operation Of Repair By Cycling Water With No Issues At This Time.