Technician Invoice Notes: Upon Arrival Found Furnace Trying To Cycle But Hot Surface Ignitor Not Getting Power. Upon Further Investigation Found Burnt Relay On Control Board. Replaced Control Board And Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 58°. Inspected Heat Exchangers Finding No Failures At This Time But There Are Signs Of Fatigue.
La Porte, IN
02-18-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Intake Clogged With Ice. Cleared Ice And Cycled Furnace To Insure Proper Operation. Furnace Is Operating Properly At This Time With A Temperature Rise Of 50°.
La Porte, IN
02-18-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call To Inspect Humidifier For Proper Operation. Upon Arrival Found Low Voltage Wiring Not Connected To Furnace. Repaired Low Voltage Wiring And Checked Humidifier For Proper Operation.
La Porte, IN
02-15-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Upon Arrival Customer Stated Furnace Was No Longer Making Noise. Inspected Heat Exchangers Finding No Failures At This Time. Blower Motor Is Operating Within Manufactures Specs. Inspected Air Filter And Blower Wheel. Inducer Motor Is Operating Within Manufactures Specs. Furnace Is Operating Properly At This Time With A Temperature Rise Of 65°.
La Porte, IN
02-15-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Unit In Lockout Due To Pressure Switch Fault. After Further Investigation Found Water Blocked Pressure Switch Port. Performed Inducer Service Bulletin And Increased Unit Fan Speed. Also Inspected Heat Exchanger Assembly And Cleaned Flame Sensor As A Preventative Measure. Replaced Air Filter And Cycled Unit From The Thermostat. Unit Is Heating Properly At This Time With A Temperature Rise Of 56°.
La Porte, IN
02-11-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For Intermittent Heat. Upon Arrival Found Furnace Heating. After Further Investigation Found Pressure Switch Operating Intermittently. Inspected Heat Exchanger Assembly And Cycled Furnace To Ensure Proper Operation. Unit Is Heating Properly At This Time With A Temperature Rise Of 60 Degrees.
La Porte, IN
02-11-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For Condensing Unit Running Continuously. Upon Arrival Found Outdoor Condenser Fan Motor Spinning With No Call For Cooling. After Further Investigation Found Shorted Wiring In Condenser Causing Bad Feed Through One Winding Of The Motor. Repaired Wiring And Cycled Condenser Fan. Explained To Client That The Compressor Operation Cannot Be Tested Until Warmer Weather. Left Power Supply Off To Condenser.
La Porte, IN
02-02-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Failed HSI. Replaced HSI And Inspected Heat Exchanger Assembly. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 57°.
La Porte, IN
01-20-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For Water Leaking From Furnace. Upon Arrival Found Collector Box Leaking. Re-sealed Furnace Collector Box And Inspected Primary And Secondary Heat Exchangers. Replaced Furnace Control Due To Terminal Breakage Upon Removal. (No Charge To Client For Control Board) Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With No Water Leaks. Inducer Motor Amperage Is At Maximum Rating; No Actions Taken At This Time. Also Found Vent Piping Rotted On Atmospheric Water Heater. After Further Investigation Found Chimney Plugged Beyond Use. Isolated Water Heater Gas Supply And Created Estimates For Replacement Water Heater Options.
La Porte, IN
01-12-2021
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Furnace In Lockout Due To Open Blower Limit. After Further Investigation Found Unit With Lack Of Airflow. Reset Limit, Increased Blower Speed, Opened Return Air Register And Installed Fiber Glass Air Filter. Unit Is Heating Properly At This Time With A Temperature Rise Of 52°. Inducer Motor Is Slightly Noisy, No Action Taken At This Time. Client Requests A Mailed Receipt.
La Porte, IN
01-04-2021
Furnace Service And Repair La Porte, Indiana
Echnician Invoice Notes: Call For No Heat. Upon Arrival Found Cracked Pressure Switch Tubing. Replaced Tubing And Relocated Pressure Switch To Help Keep Heat Away From Pressure Switch Tubing. Also Cleaned Pilot Assembly, Oiled Inducer Motor And Inspected Primary Heat Exchanger Assembly. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 71°.
La Porte, IN
12-22-2020
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For Intermittent Heat. Upon Arrival Found Furnace Operating Properly. After Further Investigation Found Flame Sensor Dirty. Clean And Tested Flame Sensor. Inspected Heat Exchanger Assembly. Unit Is Heating Properly At This Time With A Temperature Rise Of 42°.
La Porte, IN
12-18-2020
Furnace Service And Repair La Porte, Indiana
Technician Invoice Notes: Call For Furnace Motor Making Noise. Upon Arrival Found Inducer Motor Loud Due To Failing Bearings. Inspected Heat Exchangers And Found No Failures At This Time. Need To Order A New Inducer Motor Assembly And Call To Schedule A Time To Return To Install.