At Dye Plumbing & Heating, we install and service all brands of central air conditioning and cooling systems in Union Mills, IN. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Union Mills, IN.

Let us help you decide how best to solve your air conditioning needs today.

Get Your Quote Today



Dye Plumbing & Heating AC Cooling And Air Conditioning Systems Union Mills, Indiana



Recent AC Cooling And Air Conditioning Systems Union Mills, Indiana by Dye Plumbing & Heating

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Upon Arrival Augered Kitchen Sink Drainage 25’ Multiple Times To Clear Grease Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Hot Water While Observing Proper Flow At This Time. When Cycling Water Found Multiple Leaks In Under Sink Drainage. Attempted To Repair Existing Piping. Replaced Under Sink Drainage With New 1 1/2” Pvc Tubular. Tested By Cycling Large Amounts Of Water With No Issues At This Time.
Union Mills, IN
12-31-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Replaced Valve Cartridge In Delta 1700 Tub/shower Valve. Tested Operation.
Union Mills, IN
12-29-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Upon Arrival Found Existing Pop Up Assembly Leaking In Multiple Places Along With Stopper Not Rising Correctly. Replaced With New Pop Up Assembly. Tested Operation Of Installation By Cycling Water With No Issues At This Time.
UNION MILLS, IN
12-10-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Door Switch Caused By Loose Wire Connection (bypassed Door Switch At This Time And Will Access Next Spring). Performed Usp Furnace Service. Inspected Blower Wheel, Air Filter And Evaporator Coil. Cleared Drain Lines, Inducer Signal Port And Condensate Trap. Cleaned Burners, Crossovers And Flame Sensor. Igniter 47 Ohms. Inspected Primary And Secondary Heat Exchangers Finding No Failures At This Time (primary Heat Exchanger Cells Are Showing Signs Of Fatigue). Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 58°. Completed Carbon Monoxide Test Finding 0ppm At This Time.
UNION MILLS, IN
12-02-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Line Voltage Fuse Blown. Also Found Failed Transformer And Burnt Low Voltage Wiring Inside Burner Compartment. After Further Investigation Found Heat Exchanger Assembly With Multiple Cracks Causing Inadequate Combustion And Potentially Allowing Carbon Monoxide Into The Home. Shut Furnace Off At Gas Supply And Capped Gas Line As A Safety Precaution. Explained To Client That The Furnace Will Need Replaced And Can No Longer Be Operational. Client Requests An Estimate For A Replacement Furnace As Soon As Possible.
UNION MILLS, IN
12-02-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Performed Furnace Service. Inspected Blower Wheel, Evaporator Coil And Replaced Filter. Inspected Burners And Crossovers. Cleaned Flame Sensor, Cleared Inducer Signal Port, Condensate Trap And Drain Lines. Cleared Bugs And Debris From Inside Furnace Around Burners. Inspected Heat Exchangers Finding No Failures At This Time. Also Completed Carbon Monoxide Test Finding 0 Ppm At This Time. Inspected Humidifier Pad And Tested Blower Motor Capacitors. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 45° Low And 54° High. Igniter At 50 Ohms.
Union Mills, IN
11-16-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Furnace Was Off Upon Arrival. Fault Code Was For Pressure Switch Stuck Open. Client Had Tried To Replace Switch. Cleared Inducer Port, Removed Venting At Top Of Furnace And Found Dead Hawk Blocking Vent At The Top Of Furnace. Removed Hawk And Inspected Chimney Clean Out. A Lot Of Old Bird Debris At Bottom Of Chimney But Chimney Is Open. Client To Remove Bird Debris From Chimney. Started Furnace And Observed Slow Ignition Across All Burners. Removed Burners And Brushed Clean. Cleaned Flame Sensor And Inspected Heat Exchanger. No Confirmed Failures On Heat Exchanger. Started System And Cycled To Observe Operation. Measured Temperature Rise At 50 Degrees. Furnace Operating Normally At This Time.
UNION MILLS, IN
10-23-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Upon Arrival Provided Estimate For Installation Of Kitchen Faucet , Lav Faucet , And Installation Of Dishwasher Water Supply Line. Client Denied Lav And Kitchen Faucet Installation At This Time. Installed Dishwasher Supply Line And New Stop Valve Supplying Dishwasher Supply Line. Tested Operation Of Installation By Cycling Dishwasher With No Issues At This Time.
Union Mills, IN
07-31-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
40 Gallon L.P. Water Heater: Remove And Dispose Of Existing Water Heater. Provide And Install One New Bradford White L.P. Atmospheric Vent Water Heater. Model: Rg240t6x-264; Serial: Tj43963904
Union Mills, IN
07-27-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Upon Arrival Found Failing Capacitor In A/c Unit And Failed Fuse In The Safety Switch. Replaced Both Fuse And Capacitor, Unit Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
UNION MILLS, IN
07-22-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Replaced Failed Well Tank. Replaced Attached Piping And Pressure Switch To Accommodate New Tank And Relief Valve . Installed New Wellmate 6 Serial Number 127205313. Pressurized System And Tested Operation.
Union Mills, IN
07-20-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Investigated And Found Client Installed Hose Faucet Leaking At Connections In Crawlspace. Removed Hose And Replaced Section Of Piping. Pressurized And Tested.
Union Mills, IN
07-13-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected Indoor Blower Wheel, Evaporator Coil And Air Filter. After Further Investigation Found Failed Dual Run Capacitor In Outdoor Condensing Unit. Replaced Dual Capacitor And Cycled System From The Thermostat. Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil. Recommend Washing Outdoor Condenser Coil With A Garden Hose For Optimum Efficiency.
Union Mills, IN
06-23-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Investigated And Found Sewage Pump Failed. Removed And Replaced Pump. Installed New 2” Pvc Check Valve. Sealed Pit Lid With Silicone. Cycled System To Test Operation.
Union Mills, IN
06-18-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Armstrong 4SCU13LE148P-5; Serial: 1619G10849 Series Outdoor Condensing Unit - 13 SEER Efficiency Rating - Insulated Sound Blanket To Help Reduce Operating Noise - Safety Refrigerant Pressure Switches Armstrong Model:HE35248A200A0000AP; Serial: 7119J07865 Series Indoor Evaporator Coil SCOPE OF WORK: 1. Remove And Dispose Of The Existing Condensing Unit And Copper Refrigeration Line-set Piping. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. - Install The Appropriate Piston Metering Device Supplied With The Outdoor Condensing Unit. 3. Provide And Install The New Outdoor Condensing Unit On A Field Supplied Composite Pad In The Same Location. - Remove And Dispose Of The Existing Concrete Pad - The Removal Of One Landscaping Block Will Be Necessary. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit And Service Disconnect. Provide A New Electrical Whip And Replace The Existing Circuit Breaker With A New 50 AMP Breaker. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit. 6. Install New Condensate Drain Piping From The New Evaporator Coil Terminating To The Nearby Floor Drain. 7. Start The New Equipment And Check System Operation.
UNION MILLS, IN
05-20-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Armstrong 4SCU13LE148P-5; Serial: 1619G10849 Series Outdoor Condensing Unit - 13 SEER Efficiency Rating - Insulated Sound Blanket To Help Reduce Operating Noise - Safety Refrigerant Pressure Switches Armstrong Model:HE35248A200A0000AP; Serial: 7119J07865 Series Indoor Evaporator Coil SCOPE OF WORK: 1. Remove And Dispose Of The Existing Condensing Unit And Copper Refrigeration Line-set Piping. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. - Install The Appropriate Piston Metering Device Supplied With The Outdoor Condensing Unit. 3. Provide And Install The New Outdoor Condensing Unit On A Field Supplied Composite Pad In The Same Location. - Remove And Dispose Of The Existing Concrete Pad - The Removal Of One Landscaping Block Will Be Necessary. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit And Service Disconnect. Provide A New Electrical Whip And Replace The Existing Circuit Breaker With A New 50 AMP Breaker. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit. 6. Install New Condensate Drain Piping From The New Evaporator Coil Terminating To The Nearby Floor Drain. 7. Start The New Equipment And Check System Operation.
UNION MILLS, IN
05-20-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes:Removed Failed Water Heater. Installed New 50 Gallon Electric Water Heater And New Ball Valve On Incoming Cold Feed. Model Number : RE350S6-1NCWW Serial Number: TK44099017 Filled And Cycled Unit.
Union Mills, IN
05-05-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Investigated Phantom Flush. Found Sewer Unvented And Improperly Plumbed For Bathroom Group. Closet Flange Inserted Into Broken Cast Iron Riser And Bathtub Drain Piping Improperly Trapped. Dug Up Septic Tank And Found Tank Level Below Inlet. Ran Camera Through Line Back To House To Investigate Possible Partial Obstruction Causing Toilet To Siphon Bowl Water. Unable To Get Camera Into Line Farther Than Two Feet Before Disjointed Connection Obstruction Not Allowing Camera To Travel Farther. Recommend Replacement Of Sewer Line From House To Septic Tank Due To Internal Condition And What Was Observed Of Outside Conditions Of Sewer Line.
Union Mills, IN
03-28-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Call For Boiler System Circulating Excessive Amounts Of Air. Isolated Boiler And Replaced Auto Air Vent, Relief Valve, And Drained Expansion Tank. Upon Re-pressurizing System Found Failed Fill-trol Expansion Tank. Replaced Fill-trol And Cycled Boiler From All Four Zones. Bled Accessible Radiation And Observed Unit Operation. All Radiation Is Heating Properly At This Time And Unit Cycles Off At 180° With A Pressure Of 15 PSIG.
UNION MILLS, IN
03-18-2020