AC Cooling and Air Conditioning Systems

Dye Plumbing & Heatingstarstarstarstarstar5.0 / 5

5 stars
64
4 stars
1
3 stars
0
2 stars
0
1 stars
0

65 Total Reviews Dye Plumbing & Heating219-362-6251$1600 Lake Street, LaPorte IN

AC Cooling And Air Conditioning Systems Union Mills, Indiana

At Dye Plumbing & Heating, we install and service all brands of central air conditioning and cooling systems in Union Mills, IN. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Union Mills, IN.

Let us help you decide how best to solve your air conditioning needs today.

Get Your Quote Today



Dye Plumbing & Heating AC Cooling And Air Conditioning Systems Union Mills, Indiana



Recent AC Cooling And Air Conditioning Systems Union Mills, Indiana by Dye Plumbing & Heating

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected Indoor Blower Wheel, Evaporator Coil And Air Filter. After Further Investigation Found Failed Dual Run Capacitor In Outdoor Condensing Unit. Replaced Dual Capacitor And Cycled System From The Thermostat. Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil. Recommend Washing Outdoor Condenser Coil With A Garden Hose For Optimum Efficiency.
Union Mills, IN
06-23-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes: Investigated And Found Sewage Pump Failed. Removed And Replaced Pump. Installed New 2” Pvc Check Valve. Sealed Pit Lid With Silicone. Cycled System To Test Operation.
Union Mills, IN
06-18-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Armstrong 4SCU13LE148P-5; Serial: 1619G10849 Series Outdoor Condensing Unit - 13 SEER Efficiency Rating - Insulated Sound Blanket To Help Reduce Operating Noise - Safety Refrigerant Pressure Switches Armstrong Model:HE35248A200A0000AP; Serial: 7119J07865 Series Indoor Evaporator Coil SCOPE OF WORK: 1. Remove And Dispose Of The Existing Condensing Unit And Copper Refrigeration Line-set Piping. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. - Install The Appropriate Piston Metering Device Supplied With The Outdoor Condensing Unit. 3. Provide And Install The New Outdoor Condensing Unit On A Field Supplied Composite Pad In The Same Location. - Remove And Dispose Of The Existing Concrete Pad - The Removal Of One Landscaping Block Will Be Necessary. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit And Service Disconnect. Provide A New Electrical Whip And Replace The Existing Circuit Breaker With A New 50 AMP Breaker. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit. 6. Install New Condensate Drain Piping From The New Evaporator Coil Terminating To The Nearby Floor Drain. 7. Start The New Equipment And Check System Operation.
UNION MILLS, IN
05-20-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Armstrong 4SCU13LE148P-5; Serial: 1619G10849 Series Outdoor Condensing Unit - 13 SEER Efficiency Rating - Insulated Sound Blanket To Help Reduce Operating Noise - Safety Refrigerant Pressure Switches Armstrong Model:HE35248A200A0000AP; Serial: 7119J07865 Series Indoor Evaporator Coil SCOPE OF WORK: 1. Remove And Dispose Of The Existing Condensing Unit And Copper Refrigeration Line-set Piping. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. - Install The Appropriate Piston Metering Device Supplied With The Outdoor Condensing Unit. 3. Provide And Install The New Outdoor Condensing Unit On A Field Supplied Composite Pad In The Same Location. - Remove And Dispose Of The Existing Concrete Pad - The Removal Of One Landscaping Block Will Be Necessary. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit And Service Disconnect. Provide A New Electrical Whip And Replace The Existing Circuit Breaker With A New 50 AMP Breaker. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit. 6. Install New Condensate Drain Piping From The New Evaporator Coil Terminating To The Nearby Floor Drain. 7. Start The New Equipment And Check System Operation.
UNION MILLS, IN
05-20-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Technician Invoice Notes:Removed Failed Water Heater. Installed New 50 Gallon Electric Water Heater And New Ball Valve On Incoming Cold Feed. Model Number : RE350S6-1NCWW Serial Number: TK44099017 Filled And Cycled Unit.
Union Mills, IN
05-05-2020

AC Cooling And Air Conditioning Systems Union Mills, Indiana
Investigated Phantom Flush. Found Sewer Unvented And Improperly Plumbed For Bathroom Group. Closet Flange Inserted Into Broken Cast Iron Riser And Bathtub Drain Piping Improperly Trapped. Dug Up Septic Tank And Found Tank Level Below Inlet. Ran Camera Through Line Back To House To Investigate Possible Partial Obstruction Causing Toilet To Siphon Bowl Water. Unable To Get Camera Into Line Farther Than Two Feet Before Disjointed Connection Obstruction Not Allowing Camera To Travel Farther. Recommend Replacement Of Sewer Line From House To Septic Tank Due To Internal Condition And What Was Observed Of Outside Conditions Of Sewer Line.
Union Mills, IN
03-28-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Union Mills, Indiana
Call For Boiler System Circulating Excessive Amounts Of Air. Isolated Boiler And Replaced Auto Air Vent, Relief Valve, And Drained Expansion Tank. Upon Re-pressurizing System Found Failed Fill-trol Expansion Tank. Replaced Fill-trol And Cycled Boiler From All Four Zones. Bled Accessible Radiation And Observed Unit Operation. All Radiation Is Heating Properly At This Time And Unit Cycles Off At 180° With A Pressure Of 15 PSIG.
UNION MILLS, IN