Water or Steam Boiler Repair

Dye Plumbing & Heatingstarstarstarstarstar4.9 / 5

163 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Water Or Steam Boiler Repair Michigan City, Indiana

If your heating system in Michigan City, IN is not working it is likely your boiler needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on hot water or steam boiler systems like yours in Michigan City, IN. Dye Plumbing & Heating service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our boiler repair, service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly.

Get Your Quote Today



Dye Plumbing & Heating Water Or Steam Boiler Repair Michigan City, Indiana



Gallery of work For Water or Steam Boiler Repair Michigan City, Indiana


Recent Water Or Steam Boiler Repair Michigan City, Indiana by Dye Plumbing & Heating

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call To Service Boiler System And Inspect Unit Operation. Cleaned Burners, Pilot Assembly And Replaced Thermocouple And Also Tested Relief Valve. Tested All Zones To Insure Proper Operation. Replaced First Floor Thermostat With New Client Provided Nest Thermostat. Set Up Stat And Tested Operation. Boiler Is Operating Properly At This Time, Boiler Cycles Off At 180° At 20 PSIG.
Michigan City, IN
12-18-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call For Boiler Relief Valve Dripping. Upon Arrival Found Relief Valve Failed. Replaced Relief Valve And Serviced Boiler System. Cleaned Burners, Measured Igniter Resistance At 87 Ohms, Oiled Inducer Motor, Inspected Vent, Tested Fill Reducing Valve, Inspected Expansion Tank And Inspected Heat Exchanger Sections. Cycled Boiler To Ensure Proper Operation And Unit Is Heating Properly At This Time. Observed System Cycle Off At 190° With A Pressure Of Approximately 19 PSIG. Client Requests A Replacement HSI To Be Ordered And Installed As A Preventative Measure.
Michigan City, IN
12-10-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Serviced Boiler System. Cleaned Burners, Cleaned Pilot Assembly, Cleaned Thermocouple, Inspected Heat Exchanger Sections, Inspected Vent, Oiled Pumps, Inspected Expansion Tank And Cycled Boiler From Both Zones To Ensure Proper Operation. Boiler Cycles Off At 160° With A Pressure Of Approximately 23 Psi. Also Replaced Customer's Batteries In All Smoke Alarms And Checked Carbon Monoxide Detectors Throughout The Home.
Michigan City, IN
11-20-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call To Service Boiler System And Investigate Relief Valve Dripping. Serviced Boiler System. Drained Expansion Tank, Tested Auto Fill Reducing Valve And Set Cold Fill Pressure To Approximately 10 PSIG. Cleaned Burners, Replaced Thermocouple As A Preventative Measure And Replaced Leaking Relief Valve. Cycled Boiler To Ensure Proper Operation And Unit Cycles Off At 170 Degrees With A Pressure Of Approximately 14 PSIG.
Michigan City, IN
11-03-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call For Boiler Not Cycling Properly. Client Suspected System Overtemp When Relief Popped Off. Cycled Boiler, Tested Aquastat And Ensured Proper Cycle Rate. Found Expansion Tank Water Logged And Causing System Pressure To Rise Above Relief Valve Point. Client Declined Replacement Of The Expansion Tank At This Time. No Further Actions Taken.
Michigan City, IN
10-29-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call For Relief Valve Dripping From Boiler System. Upon Arrival Found Expansion Tank Water Logged And Causing Boiler System To Become Over Pressurized. Drained Expansion Tank And Re-charged With Air. Filled System To Approximately 10 Psi Cold And Observed System Operation. Boiler Is Heating Properly At This Time And Cycles Off At 180° With A Pressure Of Approximately 14 Psi. Recommend Having System Serviced Annually For Preventative Maintenance Purposes.
Michigan City, IN
10-20-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Serviced Boiler System, Cleaned Burners, Cleaned Pilot Assembly, Oiled Circulator Pump Inspected Vent, Inspected Expansion Tank, Tested Relief Valve, Tested Fill Reducing Valve And Cycled Boiler To Ensure Proper Operation. Boiler Is Heating Properly At This Time And Cycles Off At 160° With A Pressure Of Approximately 16 PSIG. Also Diagnosed Janitrol Furnace Per Clients Request. Inspected Heat Exchanger Assembly And Found No Failures At This Time. After Further Investigation Found Failed Thermostat. Replaced Thermostat And Cycled Unit To Ensure Proper Operation.
Michigan City, IN
10-12-2020

starstarstarstarstar
5 Star Rating
Water Or Steam Boiler Repair Michigan City, Indiana
1. Drain And Temporarily Remove Water Heater To Gain Access To Weil Mclain Boiler. 2. Drain Boiler System And Replace Expansion Tank And Saftey Releif Valve. 3. Remove The Specified Baseboard Radiator In The Living Room. - Save The Fin Tube And Baseboard Cover. 4. Re-install The Fin Tube Radiation In The Ceiling Below The Living Room And Loop The Radiation Back Together Through The Joist Spaces. 5. Install Client Provided Circulator Pump Serving The Basement Zone. Service The Boiler System, Clean All Ignition Components, Inspect The Vent Piping, And Test The Fill Reducing Valve. 6. Fill The Boiler System And Purge All Air From Each Zone. 7. Re-install The Existing Water Heater, Fill And Test For Proper Operation. 8. Test The Boiler For Proper Operation. Test All Zones And Ensure Proper Function Of The Entire System.
Michigan City, IN
09-14-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Replaced Vent For Pool Boiler.
Michigan City, IN
07-20-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Remove And Dispose Of The Heat Exchanger Cover Plate, Burner And Associated Gaskets. 2. Clean Heat Exchanger Assembly Per Manufacturers Instructions. - Clean Condensate Trap - Vacuum Inducer Motor Assembly 3. Install A New Burner, Gaskets And Heat Exchanger Cover Plate Assembly. 4. Start Boiler And Observe Unit Operation.
Michigan City, IN
07-13-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call For Boiler Over Shooting The Indoor Thermostat Set-points. Upon Arrival Found All Thermostats Set On 62° And Registering Approximately 67° Indoor Temperature. Cycled Boiler From All Four Thermostats, Tested Pumps, Tested Relays, Tested Aquastat And Found Master Bedroom Thermostat Operating Intermittently. Replaced Master Bedroom Thermostat And Cycled Unit To Ensure Proper Operation. System Is Operating Properly At This Time And Cycles Off At 180° With A Pressure Of Approximately 16 PSIG.
Michigan City, IN
04-17-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call For Boiler Only Producing Heat In The Basement Radiation. Upon Arrival Found Boiler At Minimal Pressure And Evidence Of Tridicator Gauge Leaking. Also Found Auto-fill Reducing Valve Failed. Replaced Tridicator Gauge And Reducing Valve. Filled System To 12 PSIG Cold And Purged All Radiation Of Air. Cycled Boiler To Ensure Proper Operation And All Radiation Is Heating Properly At This Time. Boiler Cycles Off At 190° With A Pressure Of Approximately 22 PSIG.
Michigan City, IN
04-14-2020

Water Or Steam Boiler Repair Michigan City, Indiana
CALL TO CLEAN AND SERVICE BOILER. OLD MUELLER ASBESTOS WRAPPED BOILER, VACUUMED AND CHECKED CONVERSION KIT. ALIGNED TARGET PLATE, FLAME WAS BURNING ON ONE SIDE ONLY. UNIT HAS ONLY ONE AQUA-STAT AND NEEDS TWO. NO TEMPERATURE GAGE. RECOMMEND BOILER REPLACEMENT.
Michigan City, IN
04-03-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Call For Boiler Making Noise. Upon Arrival Found First Floor B&G Circulator With A Failed Coupler. Replaced Coupler And Cycled Boiler To Ensure Proper Operation. System Is Operating Properly At This Time.
Michigan City, IN
03-26-2020