Water or Steam Boiler Repair

Dye Plumbing & Heatingstarstarstarstarstar4.9 / 5

101 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Water Or Steam Boiler Repair Michigan City, Indiana

If your heating system in Michigan City, IN is not working it is likely your boiler needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on hot water or steam boiler systems like yours in Michigan City, IN. Dye Plumbing & Heating service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our boiler repair, service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly.

Get Your Quote Today



Dye Plumbing & Heating Water Or Steam Boiler Repair Michigan City, Indiana



Recent Water Or Steam Boiler Repair Michigan City, Indiana by Dye Plumbing & Heating

starstarstarstarstar
5 Star Rating
Water Or Steam Boiler Repair Michigan City, Indiana
1. Drain And Temporarily Remove Water Heater To Gain Access To Weil Mclain Boiler. 2. Drain Boiler System And Replace Expansion Tank And Saftey Releif Valve. 3. Remove The Specified Baseboard Radiator In The Living Room. - Save The Fin Tube And Baseboard Cover. 4. Re-install The Fin Tube Radiation In The Ceiling Below The Living Room And Loop The Radiation Back Together Through The Joist Spaces. 5. Install Client Provided Circulator Pump Serving The Basement Zone. Service The Boiler System, Clean All Ignition Components, Inspect The Vent Piping, And Test The Fill Reducing Valve. 6. Fill The Boiler System And Purge All Air From Each Zone. 7. Re-install The Existing Water Heater, Fill And Test For Proper Operation. 8. Test The Boiler For Proper Operation. Test All Zones And Ensure Proper Function Of The Entire System.
Michigan City, IN
09-14-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Replaced Vent For Pool Boiler.
Michigan City, IN
07-20-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Remove And Dispose Of The Heat Exchanger Cover Plate, Burner And Associated Gaskets. 2. Clean Heat Exchanger Assembly Per Manufacturers Instructions. - Clean Condensate Trap - Vacuum Inducer Motor Assembly 3. Install A New Burner, Gaskets And Heat Exchanger Cover Plate Assembly. 4. Start Boiler And Observe Unit Operation.
Michigan City, IN
07-13-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call For Boiler Over Shooting The Indoor Thermostat Set-points. Upon Arrival Found All Thermostats Set On 62° And Registering Approximately 67° Indoor Temperature. Cycled Boiler From All Four Thermostats, Tested Pumps, Tested Relays, Tested Aquastat And Found Master Bedroom Thermostat Operating Intermittently. Replaced Master Bedroom Thermostat And Cycled Unit To Ensure Proper Operation. System Is Operating Properly At This Time And Cycles Off At 180° With A Pressure Of Approximately 16 PSIG.
Michigan City, IN
04-17-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Technician Invoice Notes: Call For Boiler Only Producing Heat In The Basement Radiation. Upon Arrival Found Boiler At Minimal Pressure And Evidence Of Tridicator Gauge Leaking. Also Found Auto-fill Reducing Valve Failed. Replaced Tridicator Gauge And Reducing Valve. Filled System To 12 PSIG Cold And Purged All Radiation Of Air. Cycled Boiler To Ensure Proper Operation And All Radiation Is Heating Properly At This Time. Boiler Cycles Off At 190° With A Pressure Of Approximately 22 PSIG.
Michigan City, IN
04-14-2020

Water Or Steam Boiler Repair Michigan City, Indiana
CALL TO CLEAN AND SERVICE BOILER. OLD MUELLER ASBESTOS WRAPPED BOILER, VACUUMED AND CHECKED CONVERSION KIT. ALIGNED TARGET PLATE, FLAME WAS BURNING ON ONE SIDE ONLY. UNIT HAS ONLY ONE AQUA-STAT AND NEEDS TWO. NO TEMPERATURE GAGE. RECOMMEND BOILER REPLACEMENT.
Michigan City, IN
04-03-2020

Water Or Steam Boiler Repair Michigan City, Indiana
Call For Boiler Making Noise. Upon Arrival Found First Floor B&G Circulator With A Failed Coupler. Replaced Coupler And Cycled Boiler To Ensure Proper Operation. System Is Operating Properly At This Time.
Michigan City, IN
03-26-2020