Water Heater Service And Repair Laporte, Indiana
Upon Arrival Found Washing Machine Hose Failed And Supply Shut Off Due To Hose Causing Flooding In Basement. Replaced Washing Machine Hoses And Pressurized Observing No Further Leaks At This Time. Investigated Aged Water Heater With No Pilot Finding Insulation Saturated But No Signs Of Active Leaking From Tank Or Tank Connections. Observed Ceiling Above Saturated And Believe Leak To Have Knocked Pilot Light Out. Relit Pilot And Observed Proper Operation At This Time. Checked Venting For Proper Draft Observing Unit Drafting Properly At This Time. Informed Client Due To Age Of Water Heater And Recent Water Damage Recommend Replacement Of Water Heater. Client Denied Replacement At This Time.
LAPORTE, IN
01-10-2024
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Investigated And Found 50 Gallon Operating With Gas Control Valve Set To B Temperature Setting. Checked Water Temperature At Closest Fixture And Received A Reading Of 140 Degrees Fahrenheit On Hot Side And 52 Degrees On Cold Side. Found Outgoing Temperature Within Rating For Gas Control Valve Setting. Suspect Due To Temperature Differential Thermal Expansion Causing Temperature And Pressure Relief Valve To Operate And Drip Onto Floor. Provided Estimate For Installation Of Thermal Expansion Tank. Client Approved. Installed New Expansion Tank With Isolation Onto Incoming Cold Supply Piping To Water Heater. Replaced Temperature And Pressure Relief Valve. Pressurized System And Cycled Water Heater.
LAPORTE, IN
04-20-2022
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found 19 Year Old Whirlpool 40 Gal Standard Vent Water Heater With Severely Back Pitched Steel Venting Not Producing Hot Water. Removed Venting Finding Complete Blockage. Visually Inspected Venting Through Roof Through Basement And Found Able To See All The Way Up With No Issues Or Obstructions. Also Pulled Burner Assembly And Cleaned Large Amounts Of Carbon Build Up Off Of Pilot Assembly. Installed 4’ Of Properly Vented 3” Venting With Necessary Elbows For Water Heater. Re Lit And Tested By Cycling Water Heater On And Off Several Times While Observing Pilot Staying Lit And Proper Drafting. Before All Work Was Done Discussed With Client Age Of Water Heater And Likelihood Of Future Issues. Client Did Not Want To Replace At This Time And Just Wanted Necessary Repairs. No Other Issues At This Time.
LAPORTE, IN
08-24-2021
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Investigated And Found Lower Element Failed And Lower Thermostat Melted At Top Lug. Replaced Both Elements And Thermostats. Drained And Flushed Tank To Remove Excess Limescale Build Up. Filled And Energized Water Heater.
LAPORTE, IN
08-04-2021
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found 50 Gal Standard Vent Bradford White Water Heater Unable To Stay Lit. Previous Technician Had Pulled Burner Assembly And Cleaned Flame Sensor. Post Cleaning Flame Sensor And Testing Once More Found Gas Valve Failed. Conducted Warranty Gas Valve Replacement. Tested Operation Of Repair By Cycling Water Heater Through Proper Operations With No Issues At This Time .
LAPORTE, IN
08-04-2021
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found T P Dripping Constantly And Gas Valve Temperature Setting Set Below Hot Due To Client Attempting To Cool Water Down. Found T P Valve Extremely Hot To The Touch And Water Coming Out Of Downstairs Lav Very Hot As Well. Conducted Warranty Replacement Of Gas Valve. Re Lit Water Heater And Tested By Cycling Through Proper Operations With No Issues .
LAPORTE, IN
06-03-2021
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For No Hot Water. Upon Arrival Found Pilot Light Out. Lit Pilot, Wouldn’t Stay Lit. Replaced Thermocouple, Brushed Out Burner Chamber. Cycled Unit To Ensure Proper Operation. Unit Is Heating Properly.
LaPorte, IN
05-04-2021
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Water Heater To Have Just Engaged. Allowed Unit To Run For A Moment To Observe Operation. Unit Continues To Run Without Issue. Checked Outdoor Vent And Found It In Obstructed At Termination. Checked Water Temperature At Multiple Faucets. Relieved Temperature Readings Of 120-130 Degrees At Faucets. Unit Is Operating Properly At This Time. Recommend Flush Of Tank Style Water Heater.
LaPorte, IN
02-26-2021
Water Heater Service And Repair Laporte, Indiana
Echnician Invoice Notes: Upon Arrival Found Whirlpool Water Heater With Failed Gas Valve. Informed Client Of Findings . Client Denied Replacement And Will Contact Whirlpool For Parts.
LAPORTE, IN
02-05-2021
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Removed And Disposed Of Existing Anode Rods. Installed Two New Anode Rods. Filled Water Heater And Purged Air. Turned Unit Back On At Gas Control Valve.
LAPORTE, IN
01-15-2021
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Flexible Steel Water Piping Attached To Water Heater For Both Hot Outlet And Cold Inlet Leaking And Showing Signs Of Severe Corrosion. Replaced With Proper Fittings And Copper Piping. Also Conducted Flush And Tune On Whirlpool Standard Vent Water Heater Installed 5 Years Ago. Flushed Large Amounts Of Limescale Build Up And Installed New 3/4” Ball Valve For Drainage. Re Filled Water Heater And Cycled With No Issues At This Time.
LaPorte, IN
12-31-2020
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For Water Heater Gas Control Displaying Abnormal Fault Code And Had Heated Water Insufficiently At Least One Time. Upon Arrival Found Gas Valve Displaying Normal Operation “heartbeat” And Satisfied Tank Temperature. Cleaned Pilot Assembly And Cycled Burner From Gas Valve Control. Observe Unit Operation And Unit Is Heating Properly. Explained To Client That If Further Issues Present Themselves That A New Gas Valve Control Or New Water Heater Would Need To Be Installed.
LaPorte, IN
12-29-2020
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes:investigated 40 Gallon Bradford White Water Heater Installed In 2013. Found No Visible Sign Of Tank Leaking. Found Moisture In Temperature And Pressure Relief Valve Piping. Suspect Debris Obstruction Causing Tank Overheating. Replaced Drain Assembly To Full Port Valve And Flushed Tank. Removed And Cleaned Burner Assembly And Compartment. Replaced Temperature And Pressure Relief Valve. Reassembled And Filled. Cycled Unit And Tested Operation. Set Temperature On Gas Control Valve To “hot” Setting. While Flushing Tank Found Sump Pump Failed. Removed And Replaced With New Zoeller Sump Pump And Ridgid Pvc Quiet Check Valve.
LAPORTE, IN
12-18-2020
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Inspected Unit. Attempted To Fire And Received Low Voltage Code. Removed And Cleaned Pilot Assembly. Reassembled And Fired Unit. Inspected Operation While Cycling. Unit Cycled For Ten Minutes And Then Tripped Thermo Roll Out On Burner Compartment Door. Inspected Draft And Inlet Air Screen. Found Underside Of Combustion Air Inlet Screen To Have Obstructions On It. Cleaned And Cycled Again.
LaPorte, IN
11-24-2020
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found 75 Gal Water Heater Functioning Correctly . Pulled Burner To Clean Flame Sensor Per Client Request. Tested Operation Of Repair By Cycling Water Heater Through Proper Steps With No Issues At This Time. Also Provided Estimate For Both A 75 Gal Powervent And 50 Gal Powervent Water Heater.
LAPORTE, IN
11-03-2020
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For No Hot Water. Upon Arrival Found Water Heater Pilot Light Out. Inspected Intake Screen, Combustion Air, Venting And Pilot Assembly. Re-lit Pilot Light And Cycled Unit Several Times To Ensure Proper Operation. Milliamp Voltage Is Sufficient And Unit Is Drafting Properly. Water Heater Is Operating Properly At This Time.
LaPorte, IN
09-09-2020
Water Heater Service And Repair Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated And Found Bottom Element On Bradford White 40 GaL Electric Water Heater From 2008 Failed. Replaced Both Stats And Elements. Removed As Much Lime Scale On Bottom Of Water Heater As Possible. Re Filled Water Heater And Tested Operation Of Repair By Cycling Water Heater Through Proper Operation.
LaPorte, IN
07-16-2020