Gas Furnaces Laporte, Indiana
Technician Invoice Notes: Provided And Installed A New LP Conversion Kit On Maytag Furnace. Replaced Gas Valve Spring And Added Safety Pressure Switch Kit. Set Manifold Pressure To Unit Specifications And Cycled Furnace To Ensure Proper Operation. Unit Is Heating Properly At This Time With A Temperature Rise Of 53°.
LAPORTE, IN
11-18-2021
Gas Furnaces Laporte, Indiana
Installation Details:
Armstrong MODEL: A95UH1E070B12S-06; SERIAL: 5920h00618 Series High Efficiency Furnace
- 95% AFUE Efficiency Rating
- Single Stage Heat Operation
- Stainless Steel Heat Exchangers
SCOPE OF WORK:
1. Remove And Dispose Of The Existing Furnace.
2. Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work.
3. Adapt The New Furnace To The Existing Gas And Electrical Circuits.
4. Adapt The New Furnace To The Existing Vent Piping.
5. Provide And Install A New Condensate Pump And Drainage Piping Adapting To The New Furnace.
6. Adapt The New Furnace To The Existing Thermostat.
7. Start The New Equipment And Check System Operation.
LAPORTE, IN
04-19-2021
Gas Furnaces Laporte, Indiana
Installation Details:
2) Armstrong MODEL: A95UH1E045B12S Series High Efficiency Furnaces
- 95% AFUE Efficiency Rating
- Single Stage Heat Operation
- Stainless Steel Heat Exchangers
SCOPE OF WORK:
1. Remove And Dispose Of The Existing Furnaces.
2. Provide And Install The New Furnaces In The Same Location Adapting To The Existing Supply & Return Air Duct Work.
3. Adapt The New Furnaces To The Existing Gas And Electrical Circuits.
4. Provide And Install New Intake And Exhaust Piping Through The Side Wall Of The Home Adapting To The New Furnaces.
5. Provide And Install New Condensate Drain Pumps And Condensate Drainage Piping Adapting To The New Furnaces And Existing Evaporator Coils.
- Terminate The New Pumps Into The Laundry Sink And Remove The Existing Discharge Tubing For The Existing Condensate Pumps.
6. Adapt The Furnaces To The Existing Thermostats.
7. Start The New Equipment And Check System Operations.
LaPorte, IN
12-31-2020
Gas Furnaces Laporte, Indiana
Armstrong MODEL: A95UH1E090C16S-06; Serial: 5920j14886 Series High Efficiency Furnace
- 95% AFUE Efficiency Rating
- Single Stage Heat Operation
- Stainless Steel Heat Exchangers
SCOPE OF WORK:
1. Remove And Dispose Of The Existing Furnace.
2. Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work.
3. Adapt The New Furnace To The Existing Gas And Electrical Circuits.
4. Adapt The New Furnace To The Existing Exhaust Piping.
5. Provide And Install A New Condensate Drain Pump And Drainage Piping Adapting To The Existing Pump Discharge Tubing.
6. Adapt The Equipment To The Existing Thermostat And Low Voltage Wiring.
7. Start The New Equipment And Check System Operation.
LAPORTE, IN
12-23-2020
Gas Furnaces Laporte, Indiana
Armstrong Furnace Model #A95UH1E070B12S-06; Serial #5920F11390
- 95% AFUE Efficiency Rating
- Single Stage Heat Operation
- Stainless Steel Heat Exchangers
SCOPE OF WORK:
1. Remove And Dispose Of The Existing Furnace. Move The Evaporator Coil Up To Allow For A Custom Supply Transition.
2. Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work.
3. Adapt The New Furnace To The Existing Gas And Electrical Circuits.
4. Provide And Install New Exhaust Vent Piping Through The Sidewall Of The Home Adapting To The New Furnace.
- Install A New Chimney Liner To Serve The Existing Water Heater.
5. Provide And Install New Condensate Drain Piping Adapting To The New Furnace.
6. Adapt The Equipment To The Existing Thermostat And Low Voltage Wiring.
7. Start The New Equipment And Check System Operation.
LaPorte, IN
12-08-2020
Gas Furnaces Laporte, Indiana
Replacement Heat Exchanger Assembly
1. Remove Existing Heat Exchanger Assembly.
2. Provide And Install One New Heat Exchanger Assembly.
3. Service The Furnace And Check All Other Components.
4. Replace The Single Wall Vent Piping With New Venting.
5. Cycle The Furnace And Test For Proper Operation.
LAPORTE, IN
11-20-2020
Gas Furnaces Laporte, Indiana
SCOPE OF WORK
1. Remove And Dispose Of The Existing Furnace.
2. Install The New Furnace, Adapting To The Existing Supply And Return Air Duct Systems.
3. Connect The Furnace To The Existing Electrical Circuits, Vent Piping And Gas Piping.
4. Provide And Install New Condensate Drainage Piping For The New Furnace Terminating To The Nearby Floor Drain.
5. Install A New Honeywell T6 Pro WiFi Thermostat In The Same Location As The Existing Thermostat. Set Up The New Thermostat With The Clients Smart Device.
6. Start The New Furnace And Check System Operation.
LAPORTE, IN
11-10-2020
Gas Furnaces Laporte, Indiana
Installation Details:
EQUIPMENT
> Armstrong High Efficiency Furnace Model: A96UH2E090C16S-01; Serial: 5920G13160
-96% Efficiency Rating
> Honeywell 5000 Series Non-programmable Thermostat
> Little Giant Condensate Pump
SCOPE OF WORK
1. Remove The Existing Furnace, Condensate Pump And Thermostat.
2. Install The New Furnace, Adapting To The Existing Duct Systems.
3. Connect The New Furnace To The Existing PVC Vent System.
4. Install The New Thermostat In The Same Location As The Existing Control.
5. Connect The Furnace To The Existing Electrical Circuit And Gas Piping.
6. Start The New Furnace And Check Operation.
LAPORTE, IN
11-03-2020
Gas Furnaces Laporte, Indiana
> Armstrong High Efficiency Furnace MODEL: A95UH1E070B12S-06; SERIAL: 5920H00634
- 95% AFUE Efficiency Rating
> Honeywell Focus Pro 6000 Programmable Thermostat
SCOPE OF WORK
1. Remove And Dispose Of The Existing Furnace.
2. Install The New Furnace, Adapting To The Existing Supply And Return Air Duct Systems.
3. Connect The Furnace To The Existing Electrical Circuit, Exhaust Piping And Gas Piping.
4. Provide And Install New Condensate Drainage Piping For The New Furnace And Adapt To The Existing Air Conditioning Evaporator Coil.
5. Install A New Honeywell Focus Pro 6000 Thermostat In The Same Location As The Existing Thermostat.
6. Start The New Furnace And Check System Operation.
LaPorte, IN
11-03-2020
Gas Furnaces Laporte, Indiana
Armstrong MODEL: A95UH1E090C16S-06; SERIAL: 5920G05283 Series High Efficiency Furnace
- 95% AFUE Efficiency Rating
- Single Stage Heat Operation
- Stainless Steel Heat Exchanger
SCOPE OF WORK:
1. Remove And Dispose Of The Existing Furnace.
2. Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work.
3. Adapt The New Furnace To The Existing Gas And Electrical Circuits.
4. Provide And Install New Exhaust Vent Piping Through The Sidewall Of The Home Adapting To The New Furnace.
- Cap The Penetration In The Chimney.
5. Provide And Install A New Condensate Drain Pump And Condensate Piping From The New Furnace And Existing Evaporator Coil.
6. Adapt The Equipment To The Existing Thermostat And Low Voltage Wiring.
7. Start The New Equipment And Check System Operation.
LAPORTE, IN
10-20-2020
Gas Furnaces Laporte, Indiana
Installation Details:
Armstrong MODEL: A95UH1E090C16S-06; SERIAL: 5920G24253 Series High Efficiency Furnace
- 95% AFUE Efficiency Rating
- Single Stage Heat Operation
- Stainless Steel Heat Exchanger
SCOPE OF WORK:
1. Remove And Dispose Of The Existing Furnace.
2. Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work.
3. Adapt The New Furnace To The Existing Gas And Electrical Circuits.
4. Adapt The New Furnace To The Existing Exhaust Vent Piping.
5. Provide And Install New Condensate Drainage Piping Adapting To The New Furnace.
6. Provide And Install A New Honeywell Wifi Thermostat In The Same Location As The Existing Thermostat. Model: TH6320WF2003. GATEWAY: ARRIS SURFBOARD SC6183-SB
7. Start The New Equipment And Check System Operation.
LaPorte, IN
10-12-2020
Gas Furnaces Laporte, Indiana
Technician Invoice Notes: Replaced Inducer Motor Assembly, Pressure Switch And Vent Piping Per Proposal Details, Cycled Furnace To Insure Proper Operation, System Is Working Proper At This Time With A Temperature Rise Of 53°.
LaPorte, IN
10-05-2020