At Dye Plumbing & Heating, we install and service all brands of central air conditioning and cooling systems in Laporte, IN. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Laporte, IN.

Let us help you decide how best to solve your air conditioning needs today.

Get Your Quote Today



Dye Plumbing & Heating AC Cooling And Air Conditioning Systems Laporte, Indiana



Recent AC Cooling And Air Conditioning Systems Laporte, Indiana by Dye Plumbing & Heating

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Attached Ice Maker Line For Fridge To Water Supply Piping Underneath Kitchen Sink. Tested Operation Of Installation By Cycling Water With No Issues At This Time.
LaPorte, IN
10-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Aged Sump Pump Not Shutting Off After Cycling. Removed And Installed New Zoeller Sump Pump With Quiet Check Valve. Tested Operation Of Installation By Cycling Sump Pump Multiple Times With No Issues.
LaPorte, IN
10-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed Paneling In Bedroom Closet. Installed New 3” Pvc Vent From Basement To Roof Termination Through Bedroom Closet Wall. Installed New Roof Flashing. Removed And Replaced Leaking Lavatory Drain. Installed New 1 1/2” Pvc From Undersink To New 3” Pvc In Basement. Tested Installation.
LAPORTE, IN
10-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Furnace Displaying Fault Code 31 For Pressure Switch Fault. Cleared All Drain Lines, Cleared Condensate Trap, And Found Switch Operating Intermittently. Replaced Pressure Switch, Replaced Client Provided Air Filter, And Cleaned Flame Sensor As A Preventative Measure. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of Degrees.
LaPorte, IN
10-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Bryant Gravity Boiler. Cleaned Burners, Cleaned Pilot Assemblies, Inspected Heat Exchanger, Inspected Vent Assemblies, Drained Expansion Tank, Tested Relief Valve, Tested Fill Reducing Valve And Cycled Boiler To Ensure Proper Operation. Observed Boiler Cycle Off At 160° With A Pressure Of Approximately 24 PSIG.
LaPorte, IN
10-20-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP Furnace Service Per Member Agreement. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 54 Ohms, Cleaned Condensate Trap, Inspected Air Filter, Inspected Blower Wheel, Inspected Evaporator Coil, Inspected Humidifier Pad And Inspected Primary And Secondary Heat Exchangers. Cycled Furnace And Humidifier To Ensure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 54°. Set Humidistat Back To Clients Setting Of 25%.
LAPORTE, IN
10-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Furnace, Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 76 Ohms, Inspected Blower Wheel, Inspected Evaporator Coil, Inspected Electronic Air Cleaner, Inspected Vent And Inspected Heat Exchanger Cells. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 41 Degrees On Low Stage And 62 Degrees On High Stage.
LaPorte, IN
10-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Armstrong MODEL: A95UH1E090C16S-06; SERIAL: 5920G05283 Series High Efficiency Furnace - 95% AFUE Efficiency Rating - Single Stage Heat Operation - Stainless Steel Heat Exchanger SCOPE OF WORK: 1. Remove And Dispose Of The Existing Furnace. 2. Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work. 3. Adapt The New Furnace To The Existing Gas And Electrical Circuits. 4. Provide And Install New Exhaust Vent Piping Through The Sidewall Of The Home Adapting To The New Furnace. - Cap The Penetration In The Chimney. 5. Provide And Install A New Condensate Drain Pump And Condensate Piping From The New Furnace And Existing Evaporator Coil. 6. Adapt The Equipment To The Existing Thermostat And Low Voltage Wiring. 7. Start The New Equipment And Check System Operation.
LAPORTE, IN
10-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed New Round Front Right Height American Standard Toilet. Tested Operation Of Installation By Cycling Toilet Multiple Times With No Issues. Also Augered Kitchen Drain 15’ Multiple Times To Clear Obstructions. Tested Operation Of Repair By Cycling Kitchen Faucet While Observing Proper Drainage At This Time. Will Order Client Widespread Lav Faucet For Pedestal Sink And Install One More Round Front Right Height American Standard When Faucet Is Ordered. Client Would Like Mailed Receipt.
LaPorte, IN
10-19-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Remove And Dispose Of One Floor Toilet. Remove And Dispose Of Existing Cast Iron Toilet Flange And Other Drainage Piping In The Basement. Note, Existing Piping Shall Remain For The Main Vent Inside The First Floor Wall And The Nearest Fitting To The Foundation Wall As Practical. Provide And Install A New PVC Toilet Flange And Where Cast Iron Was Removed For The Following: One Kitchen Sink Drain One Sump Pump Drain (re-located To Mitigate The Affects On Other Fixture Drains). One Open Site Laundry Drain One Toilet Drain One Main Vent Connection Attachments To Existing Piping Shall Be Made Using Standard Fernco Rubber Couplings. Install New Client Provided Toilet And Test Installations.
LaPorte, IN
10-19-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed Client Provided Dishwasher. Tested Operation Of Installation By Cycling Dishwasher With No Issues At This Time.
LaPorte, IN
10-19-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Service Boiler System And Check For Odd Smell In Mechanical Room. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 5 Ohms, Cleared Condensate Trap, Tested Relief Valve And Tested Fill Reducing Valve, Cleaned Inducer Signal Port And Cycled Boiler From All Four Zones To Ensure Proper Operation. Observed System Operate Properly And Cycle Off At 200° With A Pressure Of Approximately 21 PSIG. Inspected All Venting On Both Boiler And Water Heater And Performed A Carbon Monoxide Test In The Mechanical Room. Could Not Determine Where Cause Of Smell Is Originating. Recommend Client To Inspect Perimeter Drain System.
LaPorte, IN
10-19-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP Furnace Service, Cleaned Burners, Cleaned Flame Sensor, Cleaned Condensate Trap, And Measured Igniter Resistance At 74 Ohms. Replaced Humidifier Pad. Checked Blower Wheel, Checked Air Filter, Checked AC Coil, Inspected Heat Exchangers And Found No Failures At This Time. Cycled Furnace And Humidifier To Ensure Proper Operation. The Furnace Is Heating Properly At This Time With A Temperature Rise Of 49 Degrees.
LaPorte, IN
10-19-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Furnace, Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 78 Ohms, Cleared Condensate Trap, Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Air Filters. Inspected Primary And Secondary Heat Exchangers With No Failures At This Time. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 56 Degrees.
LAPORTE, IN
10-19-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found 1 1/2” Continuous Waste End Outlet And P Trap Leaking. Replaced With New 1 1/2” Continuous Waste End Outlet And P Trap. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues At This Time.
LaPorte, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Multiple Soft Copper Joints Leaking. Replaced Failed Or Failing Joints With New L Type 1/2” Copper Attaching Onto Existing 5/8” 1/2” And 3/8” Soft Copper Supply Piping. Tested Operation Of Repairs By Re Pressurizing And Checking Solder Joints For Leaks, No Issues At This Time.
LAPORTE, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Installation Details: Armstrong MODEL: A95UH1E090C16S-06; SERIAL: 5920G24253 Series High Efficiency Furnace - 95% AFUE Efficiency Rating - Single Stage Heat Operation - Stainless Steel Heat Exchanger SCOPE OF WORK: 1. Remove And Dispose Of The Existing Furnace. 2. Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work. 3. Adapt The New Furnace To The Existing Gas And Electrical Circuits. 4. Adapt The New Furnace To The Existing Exhaust Vent Piping. 5. Provide And Install New Condensate Drainage Piping Adapting To The New Furnace. 6. Provide And Install A New Honeywell Wifi Thermostat In The Same Location As The Existing Thermostat. Model: TH6320WF2003. GATEWAY: ARRIS SURFBOARD SC6183-SB 7. Start The New Equipment And Check System Operation.
LaPorte, IN
10-12-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Drain Boiler System As Needed. Remove Bottom Flange From Pump Housing And Cut Copper Return Line To The Nearest Sound Connection. Install A New Bottom Flange With A New Boiler Drain As Needed To Repair Leak. Replace Expansion Tank With A Standard EX30 Without Integral Fill Valve. Provide And Install A New Full Size Fill Reducing Valve With Isolation For Future Valve Maintenance. Provide And Install A New Air Purge Valve At The Top Of The Boiler. Re-fill Boiler System And Bleed Radiation.
Laporte, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Possible Leak On Shower Piping. Unable To View Any Leaks Or Issues From Original Access Point For Shower Valve. Cut Small Hole In Plaster In Order To Get Proper View Of Shower Arm Connection On Shower Riser. Found When Shower Is Ran Small Amounts Of Water Leaking Around Shower Arm Threads In Wall. Removed Shower Arm And Used Thread Sealant On Threads Before Re Installing. Tested Operation Of Repair By Cycling Shower With No Leaks At Shower Arm Anymore. Informed Client Of Findings.
LaPorte, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Float Height On Fill Valve Set To High Causing Continuous Overflow Into Sewage Pit. Adjusted Float Height And Tested With No Issues. Upon Cycling Toilet Found Leaking At Base. Conducted Pull And Reset On Toilet . Tested Operation Of Pull And Reset By Cycling Toilet Multiple Times With No Issues.
LaPorte, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Pinhole Leak In Ice Maker Supply Line As Well As 3/4” Copper Hot Supply Line In Crawl Space. Conducted Repair Onn3/4” Hot Water Supply With Appropriate Fittings And New L Type Copper. Removed Ice Maker Line Per Client Request And Left Ice Maker Valve In Place In Off Position For Future Use. Also Found Leaking Occurring Around Toilet Flange Inncrawl Space. Suggested Pull And Reset Of Existing Toilet. Client Asked About A New Toilet. Installed New American Standard Right Height Elongated Bowl Toilet. Tested Operation Of All Repairs By Re Pressurizing, Cycling Toilet Multiple Times, And Checking For Leaks In Crawl. No Issues At This Time.
LaPorte, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Investigated And Found Tub Spout With Hand Held Spray Diverter Eroded And Leaking. Replaced Tub Spout And Hand Held Sprayer. Investigated Toilet. Client Stated Toilet Will Only Flush If Handle Held. Adjusted Length Of Flush Arm Chain To Correct Issue. Augered Lavatory Drain. Ran Water For Long Period Of Time To Test Operation.
LaPorte, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Toilet With Possible Obstruction In Trap. Hand Augered Multiple Times To Clear Obstructions. Tested Operation Of Repair By Cycling Toilet Multiple Times With No Issues.
LAPORTE, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Limit Tripped. After Further Investigation Found Air Filters Recently Replaced. Re-set Furnace And Replaced Failed Blower Motor Capacitor. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 60°. Recommended Replacing Air Filters More Often To Help Prevent Nuisance Limit Trips.
LAPORTE, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Callback For No Heat After Furnace Service. Upon Arrival Found Pilot Light Out. Re-lit Pilot And Cycled Furnace To Ensure Proper Operation. Found Thermocouple Slightly Out Of Adjustment. Re-positioned Thermocouple And Furnace Is Heating Properly At This Time.
LAPORTE, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP Furnace Service: Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 77 Ohms, Cleaned Inducer Signal Port, Cleaned Vent And Inducer Assembly, Inspected Blower Wheel, Air Filter, Evaporator Coil And Heat Exchanger Cells. Unit Is Heating Properly At This Time With A Temperature Rise Of 67 Degrees.
LaPorte, IN
10-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Boiler, Cleaned Burners, Cleaned Pilot Assembly, Replaced Thermocouple, Inspected Heat Exchanger Sections, Tested Relief Valve, Cycled All Main Floor Zones And All Radiation Is Heating. Boiler Is Heating Properly At This Time And Shuts Down At 190 Degrees @ 18 PSI. Client Requests A Mailed Receipt.
LaPorte, IN
10-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP Furnace Service Per Plan Requirements. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 53 Ohms, Cleaned Condensate Trap And Hoses, Inspected Blower Wheel, Inspected Air Filter And Inspected Primary And Secondary Heat Exchangers. Also Inspected Humidifier Pad And Ensured Humidifier Is Operational. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 57 Degrees.
LaPorte, IN
10-06-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Temporarily Remove The Vanity Cabinet And Sink In The Hallway Bathroom. Remove The Toilet In The Hallway Bathroom. Remove Drywall As Needed Behind The Vanity Cabinet To Expose The Existing Lavatory Drains. Remove And Dispose Of Galvanized Lavatory Drains. Provide And Install New PVC Drainage As Needed To Replace The Galvanized Where Removed. Re-install Existing Vanity Cabinet, Sink And Toilet. Note: All Attempts Will Be Made To Contain The Drywall Removal Within The Vanity Cabinet Dimensions, However It May Be Necessary To Remove Additional Drywall To Properly Access The Existing Cast Iron Vent.
LaPorte, IN
10-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Observed Proper Pressure An Operation Of Shallow Well Pump And Tank. Found Large Amounts Of Build Up In All Aerators Causing Low Flow. Checked All Appliances For Proper Operation And Flow. Cleaned Aerators And Tested With No Issues At This Time. Informed Client Of Aging Shallow Well Pump.
LaPorte, IN
10-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Replaced Inducer Motor Assembly, Pressure Switch And Vent Piping Per Proposal Details, Cycled Furnace To Insure Proper Operation, System Is Working Proper At This Time With A Temperature Rise Of 53°.
LaPorte, IN
10-05-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found 50 Gal Standard Vent Water Heater Leaking At Base Into Drain Pan . Replaced Failed Water Heater With New Bradford White 50 Gal Standard Vent Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Operation With No Issues.
LaPorte, IN
10-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
GENERAL PLUMBING / PIPING REPAIR: Scope: Abandon In Place The Existing Kitchen Drain Piping In The Wall Between The Bathroom And Kitchen. Drill A New 2 Inch Hole Through The Kitchen Cabinet Floor And Kitchen Sub-floor. Provide And Install New 1-1/2 PVC Piping, Basket Strainers And Drain Trap As Needed To Re-route The Kitchen Sink And Dishwasher Drains To The Existing 3 Inch PVC Drainage In The Basement. Cap The Old Drain Piping In The Wall And Install An Air Admittance Vent Under The Kitchen Sink To Aid In Venting.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found All Three Toilets Cycling Normally. Cycled Out Of Order Toilet Several Times With No Issues. Believe Soft Clog In Trap Broke Itself Loose Over Time.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Investigated Kitchen Gurgling When Above Ground Sump Pump For Laundry Machine Is In Use. Found Double Inlet Tee Supplying Sump Pump And Kitchen Sink. Removed Septic Lid And Found Tank Almost Full But Not Obstructing Inlet . Inspected Roof Venting And Suspect Venting To Be Part Of The Issue. Client Stated The Plan On Having Entire Plumbing System Redone In The Near Future. Client Accepted Laundry Tub Installation After Originally Denying And Paying For Diagnostic Fee . Installed Laundry Tub Faucet Client Provided, Ran 10’ Of 1/2” Copper And Necessary Fittings For New Tub Along With Two Stop Valves And Appropriate 1 1/2” Pvc Fittings For Drainage . Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues At This Time .
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Inspect Clients Filter Slot For Enter Ease Of Access. Replaced Client Supplied Air Filter And Gathered Information To Re-configure The Filter Access.
LAPORTE, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service. Cleaned Burners And Crossovers. Inspected Pilot Assembly And Spark Igniter. Checked Blower Wheel And Replaced Client Provided Air Filter. Inspected Heat Exchangers And Found No Failures. Inspected Evaporator Coil And Found It Slightly Dirty; No Actions Taken At This Time. Cycled System To Test Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 44 Degrees. Also Performed A Carbon Monoxide Test And Unit Is Emitting No Carbon Monoxide Gases At This Time.
LAPORTE, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Flame Rollout During Furnace Operation. Upon Arrival Found Furnace Ignition Components Disconnected And Gas Off To The Appliance. Re-assembled Unit And Found Failed Inducer Motor With Flame Rollout. Inspected Primary Heat Exchanger Cells And Found Pin Holes In The Heat Exchanger. Shut Appliance Gas Supply Stop Off And Advised Homeowner Not To Operate The Furnace Due To The Potential For Carbon Monoxide Gases. Gathered Information To Provide An Estimate For A Replacement Furnace.
LAPORTE, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Furnace Short Cycling. Upon Arrival Cycled Unit From The Thermostat And Found Control Board Malfunctioning. Inspected Heat Exchanger Assembly And Found No Failures At This Time. Replaced Control Board And Cycled Furnace To Ensure Proper Operation. Unit Is Heating Properly At This Time With A Temperature Rise Of 55 Degrees.
LAPORTE, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Installed Client Provided Toilet. Tested Operation.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Water Heater Leaking From Tank. Removed And Replaced Unit Under Manufacturer Warranty. New Unit Model RG240T6N & Serial Number WF45455850 . Replacement Unit Is Under Manufacturer Warranty Issued At Installation Of Initial Unit 7-18-2018, And Expires 7-18-2024. Filled And Cycled Unit. Set Temperature On Gas Control Valve To “hot” Setting. Inspected Operation.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Replaced Gas Cock Serving Kitchen Stove. Replaced Two Stops Under Kitchen Sink On Hot Side. Removed Toilet For Disposal.
LaPorte, IN
09-28-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated Odor In Basement. Found Open Lavatory Drain Line In Mechanical Room, And Water Level In Trapway Low On 1/2 Bath In Basement. Did Observe Odor At Sump Pit. Sealed Pit Lid With Silicone. Filled Lavatory Trapway And Covered Lavatory Stub Out.
LaPorte, IN
09-28-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed New Gas Whip For Existing Stove. Attached On New Gas Whip And Tested Operation Of Repair By Checking Connections For Gas Leaks And Cycling Stove With No Issues At This Time.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Tub Shower Faucet Leaking When Turned Off. Client Also Stated That Tub Spout Squeals Loudly When Used. Cycled Tub Spout And Unable To Recreate Noise. Informed Client That A New Tub Spout Would Solve Issues With Noise When Existing Tub Spout Is Used. Client Denied Tub Spout Replacement At This Time. Replaced Delta Shower Cartridge And Tested Operation By Cycling Faucet With No Issues At This Time.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Thermostat Calling For Heat With No Furnace Operation. After Further Investigation Found Loose Wiring Connection At Furnace Control Board. Secured Connection And Cycled Furnace. Also Serviced Furnace Per Clients Request. Cleaned Burners, Cleaned Flame Sensor, Cleaned Condensate Trap, Measured Igniter Resistance At 74 Ohms, Inspected Blower Wheel, Inspected Evaporator Coil, Replaced Client Provided Air Filter And Inspected Primary And Secondary Heat Exchangers With No Failures At This Time. Performed A Carbon Monoxide Test And Unit Is Heating Properly At This Time With A Temperature Rise Of 56 Degrees.
LAPORTE, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Call To Service Furnace. Inspected Primary And Secondary Heat Exchangers And Found At Least One Popped Crimp Ring In The Primary Cells. Performed A Carbon Monoxide Test And Unit Is Emitting Small Amounts Of Carbon Monoxide Gas At This Time. Explained To Client Of The Potential Dangers Of Carbon Monoxide Gas And Advised Not To Use The Equipment. Gathered Information To Provide An Estimate For A Replacement Furnace. Client Will Receive The Proposal When Completed.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Furnace For The Upcoming Heating Season. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 54 Ohms, Cleaned Inducer Signal Port, Cleaned Vent And Inducer Assembly, Inspected Blower Wheel, Inspected Heat Exchanger, Inspected Evaporator Coil And Inspected Air Filter. Performed A A Carbon Monoxide Test And Unit Is Heating Properly At This Time With A Temperature Rise Of 62 Degrees.
LaPorte, IN
09-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Furnace For The Upcoming Heating Season. Cleaned Burners, Cleaned Pilot Assembly, Cleaned Thermocouple, Checked Vent, Inspected Blower Wheel, Inspected Evaporator Coil, Replaced Client Provided Air Filter And Inspected Heat Exchanger Cells. Found No Failures In The Heat Exchanger At This Time. Cycled Furnace To Ensure Proper Operation And Performed A Carbon Monoxide Test. Unit Is Heating At This Time With A Temperature Rise Of 61 Degrees.
LAPORTE, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Remove And Dispose Of Existing Bathtub And Shower Surround. Remove And Dispose Of Existing Shower Valve And Tub Drain Assembly. Provide And Install One New Delta Single Handle Shower Valve With Tub Diverter Spout And Delta
LAPORTE, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Provided Estimate For Installation Of 2- 1/2” Ball Valves On Hose Faucet Piping And Replacing Section Of 3/4” Galvanized Piping From Well Tee To Existing 3/4” Copper Piping. Client Approved. Installed New Isolation Valves On Piping Serving Hose Faucets In Front And Rear Of Home. Removed And Replaced Section Of Galvanized Piping From Well Tee. Pressurized System And Inspected Installation.
LaPorte, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Model Number : RG250T6N Serial Number : WA44474205 Found Unit Leaking . Drained And Replaced With New 50 Gallon Bradford White Water Heater Under Manufacturer Warranty. Filled And Cycled Unit. Set Temperature On Gas Control Valve To “hot” Setting.
LaPorte, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Delta Two Handle Shower Faucet Disassembled And Missing Seat/springs. Installed New Seats/springs And Reassembled Faucet. Pressurized System And Tested Operation.
LaPorte, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Inspected Toilet And Provided Estimates For Options To Correct Issues. Client Chose To Rebuild Toilet And Replace Seat. Replaced Toilet Tank Components And Installed New Seal And Floor Hardware. Installed New Seat And Set Water Level. Also Replaced Delta Tub/shower Faucet Cartridge. Tested Repairs.
LAPORTE, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Faucets Obstructed By Sand. Cleaned Aerators And Re-installed. Upon Inspection Suspect Softener Media Is Coming From Faucets. Put Unit In Bypass And Drained Bottom Of Water Heater To Remove Build Up. Ran All Faucets And No Longer Observed Sand. Also Found Hot Side On Tub/shower Faucet Stem Rounded Off And Diverter Un Operable. Replaced Tub/shower Faucet. Pressurized And Ran Large Amount Of Water Through Lavatory And Tub/shower With Issue.
LaPorte, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Faucets Obstructed By Sand. Cleaned Aerators And Re-installed. Upon Inspection Suspect Softener Media Is Coming From Faucets. Put Unit In Bypass And Drained Bottom Of Water Heater To Remove Build Up. Ran All Faucets And No Longer Observed Sand. Also Found Hot Side On Tub/shower Faucet Stem Rounded Off And Diverter Un Operable. Replaced Tub/shower Faucet. Pressurized And Ran Large Amount Of Water Through Lavatory And Tub/shower With Issue.
LaPorte, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Unable To Install Sump Pit Lid Due To Sump Pit Being Square With Multiple Pipes . Removed Failed Sewage Pump And Installed New Zoeller Sewage Pump. Upon Installation Tested And Observed Float Stuck Open . Removed Installed Pump And Found Multiple Decomposing Oranges And Large Waste Material Stopping Pump Float From Turning Off. Re Positioned Pump And Removed Decomposing Oranges. Tested Operation Of Re Installation With No Issues At This Time.
LaPorte, IN
09-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
50 GALLON POWER VENT NAT GAS: Remove And Dispose Of Existing Water Heater. Provide And Install One New Bradford White 50 Gallon Natural Gas Power Vent Water Heater. (same For Same) MODEL: RG1PV50S6N19-264; SERIAL: WF45460216
LaPorte, IN
09-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Call For Utility Locates Before Work Begins. Hand Excavate Soil Near The Foundation Of The Home And For A Distance Of Up To 15 Feet To Expose The Existing Failed Sewer Line. Note: This Proposal Assumes That All Work Will Take Place On The Outside Of The Home. This Proposal Does Not Include Further Repairs Inside Or Under The Home. Provide And Install A New PVC Outdoor Clean Out Access And Replace Existing Failed Piping With New PVC.
Laporte, IN
09-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Pressurized System And Checked Gas Piping For Leaks On Accessible Piping. Found Four Locations On Existing Piping Failed Pressurizing Test. Unable To Inspect Piping In Walls. Recommend Replacement Of Entire Gas Piping To Eliminate Numerous Leaks In Smaller Piping System.
LaPorte, IN
09-18-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Tank Leaking On 40 Gal Short Bradford White Water Heater Along With Leaking Gate Valve For Cold Water Shut Off To Water Heater. Replaced With New 40 Gal Short Bradford White Water Heater And New Ball Valve. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps With No Issues At This Time
LAPORTE, IN
09-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Found Failed Kitchen Faucet. Installed Client Supplied Kitchen Faucet. Tested Operation Of Installation By Cycling Faucet While Conducting Leak Search With No Issues At This Time.
LAPORTE, IN
09-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Unable To Identify Any Issue With Sewer System. Suspect When City Performed Maintenance On Sewer The Trap Seal Was Pulled Dry In Floor Drain.
LAPORTE, IN
09-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Kitchen Sink Drain Undersized And Poorly Pitched. Removed Entire Length Of 1 1/2” Pvc From Under Sink To Main Stack. Installed New 3” Pvc From Sink To Stack Due To Lack Of Venting For Kitchen Drainage. Installed New P Trap And Tested Installation.
LAPORTE, IN
09-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Sink And Tub Drain Backing Up But Rest Of The Homes Drainage In Good Working Order. Augered Through Kitchen Drainage 50 ‘ To Clear Large Hair And Grease Obstructions. Tested Operation Of Repair By Cycling Tub Shower And Kitchen Sink With No More Issues At This Time.
LaPorte, IN
09-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Excavated Yard To Expose Outgoing Sewer Line. Removed Section Of 4” Cast Iron From 4” Vct And Removed Through Foundation Wall. Removed Existing Cast Iron Drainage Piping In Basement Near Water Meter. Installed New Pvc Drainage In All Areas Cast Iron Removed. Installed New Piping To Kitchen Sink And New Under Sink Piping To Accommodate New Drain. Installed 4” Pvc Clean Out Our Doors. Sealed Foundation Penetration On Both Sides With Cement And Sealed Cement On Out Side With Foundation Tar Sealant. Ran Water In Drains To Test Operation On Repairs.
LaPorte, IN
09-14-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Quoted Client Pricing For Installation Of Client Supplied Garbage Disposal. Client Asked Pricing For Just Removal Of Disposal And Attaching Onto Existing Piping. Removed Garbage Disposal And Attached Onto Existing Kitchen Sink Drainage Piping With Installation Of New Basket Strainer. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues.
LAPORTE, IN
09-14-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Supply Lines In Good Working Order. But Found Unglued Drainage Fitting Causing Leaks When Lav Sink Is Used. Removed Small Section Of 2” Pvc And Installed New 2” Pvc Attaching Onto Existing Fittings Properly.
LaPorte, IN
09-14-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed Existing Water Heater, Water Softener And Piping From Both. Installed New Whole House Filter Mounted To Wall. Installed New Sterling Water Softener. Installed New 50 Gallon Bradford White Water Heater With Power Vent. Model: RG1PV50S6N19 Serial: WH46347849 Pressurized System And Filled Water Heater. Programed Water Softener To Water Specifications. Tested Water For Softness. Set Temperature On Gas Control Valve To “hot” Setting.
LaPorte, IN
09-14-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Existing Pedestal Pump To Have Many Dryer Sheets Clogging Impeller And Disabling Sump Pump. Removed Pedestal Pump. Installed New Zoeller Submersible Sump Pump And Pvc Quiet Check Valve. Cycled Pump To Test Operation And Installation. Advised Client Of Debris Entering Sump Pit And Damages To Pump By Anything Other That Water. Client Also Stated Having Drainage Issues In Basement And At Kitchen Sink. Provided Estimate For Replacement Of Failed Sewage Pump In Basement And Estimate For Augering Of Kitchen Sink Drain.
LaPorte, IN
09-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No Hot Water. Upon Arrival Found Water Heater Pilot Light Out. Inspected Intake Screen, Combustion Air, Venting And Pilot Assembly. Re-lit Pilot Light And Cycled Unit Several Times To Ensure Proper Operation. Milliamp Voltage Is Sufficient And Unit Is Drafting Properly. Water Heater Is Operating Properly At This Time.
LaPorte, IN
09-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Two Hose Faucets Three Feet Apart On Driveway Side Of Home Bent From Being Struck With An Automobile. Both Faucets Supplied Cold Water. Client Chose To Eliminate One And Replace The Other. Removed Both. Installed New Hose Faucet And Capped Other Line Just Past Isolation In Basement. Pressurized And Tested Installation.
LaPorte, IN
09-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Older Style Overflow Not Functioning Properly. Disassembled And Cleaned. Reinstalled And Tested.
LaPorte, IN
09-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Rebuilt Single Handle Delta Kitchen Faucet And Single Handle Delta Lav Faucet . Replaced Kitchen Faucet Handle. Tested Operation Of Repairs By Cycling Faucets With No Issues. Replaced House Water Filters And Replaced Failed Lav Faucet Downstairs With New Delta Lav Fauvet. Tested Operation Of Installation By Cycling Faucet With No Issues.
LaPorte, IN
09-09-2020

starstarstar
3 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected Blower Wheel, Air Filter And Evaporator Coil. Cycled System From The Thermostat And Found System Low On R-22 Refrigerant. Added Up To 2#’s Of R-22 Refrigerant And System Is Cooling Properly At This Time With A Temperature Drop Of 19 Degrees Across The Evaporator Coil. Client States That Refrigerant Is Frequently Added To The System. Explained To Client That The System Has A Large Leak Somewhere And The Problem Will Persist In The Future. Due To The Systems Age And Condition It Is Highly Recommended That The A/C System Be Replaced.
LaPorte, IN
09-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Boiler System, Cleaned Burners, Cleaned Flame Sensor, Cleaned Spark Igniter, Tested Pressure Relief Valve, Drained Expansion Tank, Tested Auto Fill Valve And Set System Pressure To Approximately 12 Psi Cold. Cycled Boiler System From All Zones To Ensure Proper Operation And The System Is Heating At This Time. Boiler Shuts Down At 185 Degrees With A Pressure Of Approximately 15 Psi.
LaPorte, IN
09-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Water Leaking From A/C System In Attic. Upon Arrival Found Water Leaking From Evaporator Coil Condensate Pan. Cleared Plugged Drain Line And Found A Crack In The PVC Piping. Replaced Condensate Trap Located At Evaporator Coil And Cycled System To Ensure Proper Operation. System Is Operating Properly With No Condensate Leaks. Explained To Client That The Plywood Floor In The Attic Is Still Very Wet And It May Take A Day Or Two To Dry Out. Water Will Continue To Drip From The Ceiling Until The Attic Floor Is Dry.
LAPORTE, IN
09-02-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Shower Faucet Dripping When Turned Off. Replaced Delta Cartridge Seats And Springs. Tested Operation Of Repair By Re Pressurizing. Cycled Faucet Multiple Times While Observing Proper Operation. No Issues At This Time.
LAPORTE, IN
09-02-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Water Leaking Through Ceiling In Basement Level. Removed Section Of Ceiling To Find Water Coming Through Flooring. Removed Section Of Wet Drywall On Rear Wall Of First Floor Vanity. Observed Leaking From Above. Removed Section Of Wall Behind Toilet On Second Floor. Found 1 1/2” Copper Piping Eroded Through. Removed Section Of Failed Piping From Under Sink To Location Of Better Condition Pipe Behind Toilet. Installed New 1 1/2” Pvc Drainage To Serve Lavatory. Ran Water To Test Operation. Advised Client To Not Repair Removed Sections Of Walls To Allow Moisture To Dry Out.
LaPorte, IN
08-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Sump Pump. Replaced With New Zoeller Sump Pump. Tested Operation Of Installation By Cycling Sump Pump Multiple Times With No Issues.
LAPORTE, IN
08-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Discussed Issues Of Scale Build Up On Shower Fixtures With Client. Client Expressed Concerns Of Soft Water For Consumption. Client Would Like Estimate For Installation Of Water Softer And New 50 Gallon Powervent Water Heater. Softener To Only Feed Water Heater With A Bypass Installed For Option Of Including Cold As Desired. Will Provide Estimate For Installation Of Unit In Room Near Water Meter And Install New 3/4” Piping To Feed New Water Heater 60’ Away. Documented Locations With Photos.
LaPorte, IN
08-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service. Cleaned Burners, Cleaned Flame Sensor, Replaced Hsi, Cleaned Condensate Trap, Inspected Blower Wheel And Evaporator Coil And Inspected Primary And Secondary Heat Exchangers. Cycled Furnace From The Thermostat To Insure Proper Operation. Unit Is Heating Properly At This Time With A Temperature Rise Of 57°. Performed Usp A/c Service. Water Washed Outdoor Condenser Coil, Removed Debris, Checked All Electrical Components And Tested For Proper Refrigerant Charge. Checked For Proper Airflow. System Is Cooling Properly At This Time With A Temperature Drop Of 20°
LAPORTE, IN
08-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
40 GALLON STD VENT NAT GAS WATER HEATER: Remove And Dispose Of Existing Water Heater. Provide And Install One New Bradford White 40 Gallon Natural Gas Atmospheric Vent Heater.
LAPORTE, IN
08-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Camera Through Outdoor Clean Out To Find Large Amounts Of Build Up Towards Home And Towards City Main . Augered 20’ Towards Home To Clear Obstructions And 75’ Out To City Main To Clear Obstructions. Cameraed Line Post Augering And Found All Root Obstructions Cleared. Cycled Large Amounts Of Water And Observed Proper Flow At City Main Inlet.
LAPORTE, IN
08-18-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Thermostat Malfunctioning. Upon Arrival Determined Thermostat To Be Faulty. Replaced Thermostat With A New Honeywell Focus Pro 5000 Non-programmable Unit And Tested System Operation.
LAPORTE, IN
08-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Serviced And Inspected A/C Per USP Membership.
LaPorte, IN
08-17-2020

starstarstarstar
4 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Failed Water Heater With Leaking Tank. Installed New 40 Gal Standard Vent Nat Gas Bradford White Water Heater. Tested Operation By Cycling Water Heater Through Proper Steps With No Issues At This Time.
LAPORTE, IN
08-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Fill Valve In Master Bathroom Toilet. Conducted Toilet Rebuild, Tested Operation Of Repair By Cycling Toilet Multiple Times With No Issues. Found Flapper On Second Toilet In Hallway Sticking And Not Cycling Correctly. Replaced Flapper And Tested Multiple Times With No Issues.
LAPORTE, IN
08-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Shower Valve. Gained Access Behind Shower Valve Assembly. Removed And Installed New Delta Shower Valve Kit. Attached Onto Existing Galvanized Water Piping . Tested Operation Of Installation By Cycling Shower Faucet And Shower Head With No Issues At This Time.
LAPORTE, IN
08-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Inadequate A/C. Upon Arrival Found Plugged Air Filter On Northern Office Unit With Several Registers Obstructed. Replaced Client Supplied Air Filter And Cleared All Obstructions. System Is Cooling Properly At This Time. Also Inspected South Office Unit And Two Package A/C Systems. Found Both Package Units With Plugged Air Filters And One Frozen. Replaced Air Filter In North Package Unit And Modified The Filter Slot To Allow The Filter To Be Installed Properly. Removed Power From South Package Unit To Allow Unit To Thaw Naturally. Need To Return To Investigate Frozen Package Unit On 8-11-20.
LaPorte, IN
08-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes:Replaced Failed Under Sink Drainage Piping. Ran Dishwasher And Water In Sink To Test Repair.
LAPORTE, IN
08-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Drop In Tub With Deck Mounted Faucet. Enclosure Is Carpet With Plywood Base. Will Provide Estimate For Installation Of Access Near Faucet And Installation Of New Blade Handled Deck Mounted Faucet.
LAPORTE, IN
08-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Temporarily Shut Down Water Supply. Drain And Remove Existing Well Tank. Remove Existing Piping From The Incoming Poly Line And Extending To The Recent Copper Repair Above The Basement Drop Ceiling. Provide And Install One New Well-Mate Size 6 Well Tank, With A New Pressure Control Switch, Well Pressure Gauge And Safety Relief Valve.Model: Wm-6 Quick Connect; Seriaal: 140208816 Provide And Install New 3/4 Copper Type
LaPorte, IN
08-10-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Tank Leaking Into Drip Pan On Bradford White Water Heater Installed In 2017. Conducted Warranty Replacement With New 40 Gal Standard Vent Nat Gas Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps With No Issues At This Time.
LaPorte, IN
08-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Downstairs Sink Faucet With Good Hot And Cold Side Pressure. Removed Sediment From Shower Head Upstairs. Proper Flow At Shower Head Now. Kitchen Faucet Downstairs With No Pressure Hot Or Cold Side, No Stop Valves At Kitchen Faucet, And Black Gas Pipe Used To Connect To Supply Lines. Informed Client Of Findings. Tested Pressure At Hot And Cold Side With Cartridges Removed. Good Pressure Through Galvanized Water Piping. Informed Client Of Failed Faucet. Removed Short Gas Nipples And Installed New Stop Valves With 2” Long 1/2” Brass Nipples At This Time. Will Return At Later Date For New Faucet Installation.
LAPORTE, IN
08-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Handle Hardware Missing And Handle Removed. Replaced Flush Handle With New Commercial Flush Handle. Tested Operation.
LaPorte, IN
08-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Arrived And Found Fill Valve Failed. Performed Toilet Tank Re-build And Set Tank Water Level. Tested Flush To Succession.
LaPorte, IN
08-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Rubber 2” Check Valve Stuck In Closed Position . Used Percussive Maintenance To Release Rubber Check And Allow Sewage Ejection Pump To Cycle. Informed Client Of Findings. Client Wished To Just Replace Check Before Replacing Pump As Well. Replaced Rubber Check Valve With New 2” Quiet Check Valve. Tested Operation Of Repair By Cycling Sewage Pump Multiple Times With No Issues. Informed Client If Issue Continues That A Replacement Pump Will Be Necessary. Investigated Slow Upstairs Tub Drain. Plunged To Clear Hair And Soap Obstructions. Cycled Large Amounts Of Hot Water For Period Of Time With No Issues.
LaPorte, IN
08-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Pulled And Reset Upstairs Toilet. Used Two Wax Rings Due To Floor Deformities. Tested Operation Of Repair By Cycling Toilet Multiple Times With No Issues. Also Conducted Toilet Rebuild On Downstairs Right Height Toilet. Tested Operation Of Repair By Cycling Toilet Multiple Times With No Issues.
LaPorte, IN
08-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Urinal Continuously Running. Disassembled Flushometer Cleaned Greased And Replaced Vacuum Breaker. Re Assembled And Tested Operation By Cycling Urinal Multiple Times With No Issues. Informed Client If Issue Continues Replacement Of Flushometer Will Be Suggested.
LAPORTE, IN
08-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed Leaking Whole House Filter Before Water Softener. Pressurized And Inspected. Also Removed Obstruction In Pop Up Assembly In Washroom Off Bedroom.
LaPorte, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed 50 Gal Powervent Bradford White Water Heater Installed In 2011. Replaced With New 50 Gal Powervent Bradford White Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps With No Issues.
LAPORTE, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Attic Exhaust Fan Not Operating. Upon Arrival Found Attic Thermostat/humidistat Receiving Power And Fan Motor Not Responding. After Further Investigation Found Failed Attic Fan Motor.
LAPORTE, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Attic Exhaust Fan Not Operating. Upon Arrival Found Attic Thermostat/humidistat Receiving Power And Fan Motor Not Responding. After Further Investigation Found Failed Attic Fan Motor.
LAPORTE, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes:removed Section Of 4” Cast Iron Where Hole Was Located. Installed 4” Section Of Pvc And Cleanout.
LaPorte, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Unable To Recreate Drip In Kitchen Faucet. Client Still Suggested Replacement Of Cartridges. Tested Operation Of Repair On Double Handle Kitchen Faucet By Cycling On And Off With No Issues At This Time.
LaPorte, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Lav Faucet. Tested Operation Of Installation Of New Faucet By Cycling Water With No Issues. Client Would Like Mailed Receipt.
LAPORTE, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed Open Site Drain For Softener Discharge. Installed Onto Venting For Sewage Ejection Pump . Tested Operation Of Installation By Cycling Sewage Ejection Pump With No Issues On The Open Site Drain Discharge.
LaPorte, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Investigate One Or More Supply Air Runs Disconnected In Crawlspace. Upon Arrival Found One Bedroom Supply Run Disconnected And Air Filter Plugged. Replaced Air Filter And Re-assembled Disconnected Duct Work. Tested All Airflow In All Rooms With Adequate Results
LaPorte, IN
08-06-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected Blower Wheel, Air Filter And Evaporator Coil. After Further Investigation Found Failed Dual Run Capacitor In Outdoor Condenser Unit. Replaced Capacitor, Cycled System From Both Thermostats And Checked System Refrigerant Levels To Ensure Proper Operation. Unit Is Cooling Properly At This Time With A Temperature Drop Of 15 Degrees Across The Evaporator Coil.
LaPorte, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Inspect A/C System. Upon Arrival Inspected All Electrical Components, Found Blower Wheel Slightly Dirty And Inspected Evaporator And Condenser Coil. Cycled System And Checked Refrigerant Levels To Ensure Proper Operation. System Is Cooling Properly At This Time With No Issues Found. Also Replaced Schrader Caps As A Preventative Measure.
LaPorte, IN
08-04-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed And Reinstalled Client Supplied Basket Strainer. Tested Operation.
LaPorte, IN
08-04-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed Existing Water Heater. Installed New 50 Gallon Bradford White Propane Water Heater With Atmospheric Vent. Due To Size Differences In Units, Piping Surrounding Water Heater Required Alterations To Accommodate New Unit. Filled And Fired Unit. Cycled And Tested Operation. Set Temperature On Gas Control Valve To “hot” Setting. Model: RG250T6S Serial : TL44343897
LaPorte, IN
08-04-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Camera Inspected 4” Pvc Line Through Clean Out In Basement. Found Minimal Low Spots At 40’-45’, Also Found Another Minimal Low Spot At 100’-120’. Cameraed 140’ Out To City Main. No Disjoints Or Other Issues With Main Sewage Line At This Time.
LaPorte, IN
08-04-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Supply Line Feeding Toilet. Tested Operation Of Repair By Cycling Toilet With No Leaks Or Issues At This Time.
LaPorte, IN
08-04-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Low Pressure To Hot Side Of Faucet . Client Would Like Two New Stop Valves Due To Age. Replaced Small Section Of 1/2” Copper With New L Type Copper And Replaced Two Stop Valves. Tested Operation Of Repair By Cycling Water Through Faucet With Proper Pressure To Both Hot And Cold. No Other Issues At This Time.
LaPorte, IN
08-04-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed A/C Service And Clean. Inspected Indoor Evaporator Coil, Air Filter, Blower Wheel And Tested For Proper Airflow. Water Washed Outdoor Condenser Coil, Removed Debris, Tested All Electrical Components And Tested For Proper Refrigerant Charge. System Is Cooling Properly At This Time With A Temperature Drop Of 17° Across The Evaporator Coil.
Laporte, IN
08-04-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Two Hose Faucets With New Wolverine Brass Hose Faucets. Tested Operation Of Installation By Re Pressurizing Home And Testing. No Issues At This Time.
LaPorte, IN
08-04-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Augered Sewer From Clean Out In Basement To City Sewer. Camera Inspected Piping. Informed Client Of Grease Build Up In Piping.
LaPorte, IN
07-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Sewer Line Obstruction Past Yard Trap In Front Yard. Augered And Removed Roots From Piping. Flushed Large Amounts Of Water To Test Operation.
LaPorte, IN
07-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Remove And Dispose Of Existing 1-1/2 Drain Pipe Serving The Washing Machine. Hand Excavate As Needed To Expose The Existing Underground Sewer Line Near The Foundation Of The Home. Provide And Install New 3 Inch PVC Through The Foundation Of The Home And Connecting To The Existing Underground Sewer. Use Hydro Cement To Seal The New 3 Inch Penetration. Provide And Install A New 2 Inch Stand Pipe For The Washing Machine Drain And Re-connect Existing Kitchen Sink Drain To The New 3 Inch Line.
LaPorte, IN
07-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Uponnarrival Replaced Delta Shower Cartridge. Adjusted Temperature Through Cartridge To Clients Liking. Tested Operation Of Installation By Cycling Water With No Issues At This Time.
LaPorte, IN
07-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Existing Stopper And Tested Operation Of Client Supplied Dollar Plug. Installed Customer Supplied Kitchen Faucet. Tested Operation Of Installation By Cycling Faucet With No Issues.
LaPorte, IN
07-31-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Urinal Unable To Shut Off After Flushing . Replaced Flushometer And Tested Operation Of Installation By Cycling Urinal. Found Urinal Stop Valves Adjustment Needing To Be Very Low In Order For Urinal To Cycle Correctly. Urinal Cycling Correctly At This Time With Somewhat Slow Drainage. Client Is Not Worried About Slow Drainage At This Time.
LaPorte, IN
07-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Inspected Kitchen Faucet Spray Head Spraying Everywhere. Unable To Break Down Spray Head To Remove Sediment Inside. Informed Client Of Issues And To Find A Replacement Spray Head Or Replacement Faucet.
LaPorte, IN
07-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found No Control Voltage At Outdoor Condensing Unit. After Further Investigation Found Failed Outdoor Contactor Failed. Replaced Contactor And Cycled System To Ensure Proper Operation. System Is Cooling Properly At This Time.
LaPorte, IN
07-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed Customer Supplied Dishwasher And Replaced One Stop Valve Supplying Dishwasher. Tested Operation Of Installation By Cycling Dishwasher And Testing For Leaks And Proper Drainage. No Issues At This Time.
LaPorte, IN
07-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Broken Supply Line Feeding Downstairs Toilet. Water Turned Off To Toilet At Shutoff Valve. Also Found Aged Toilet Tank Components And Suggested Toilet Rebuild. Client Denied And Asked For Pricing Of New Toilet And Price Of Installing Customer Supplied Toilet. Provided Estimates For Client .
LaPorte, IN
07-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found No Low Voltage Power. After Further Investigation Found Failed Low Voltage Transformer Inside Furnace. Replaced Transformer And Checked All Low Voltage Components For Short Circuits. Replaced Air Filter And Cycled System In Heating And Cooling Modes To Ensure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 15° Degrees Across The Evaporator Coil. Recommended Having A Surge Protector Installed For Either The Whole Home Or Dedicated For The Furnace To Aid In Protecting The Equipment From Electrical Surges.
LaPorte, IN
07-30-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced 50 Gal Electric Water Heater Leaking From Base With New Bradford White 50 Gal Electric Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Operation With No Issues.
Laporte, IN
07-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Pressure Test Gas Line To Pool Heater And Connect Pool Heater Piping. Pressure Tested Gas Piping To 5 PSIG. Re-connected Gas Piping To Pool Heater And Re-lit Gas Appliances. Tested Piping For Leaks And Observed Pool Heater Operation.
LaPorte, IN
07-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Water Leaking From Air Conditioning System. Upon Arrival Found Condensate Drain Plugged. Cleared Condensate Piping, Removed Water From Blower Motor And Serviced A/C System. Inspected Blower Wheel, Air Filter And Indoor Evaporator Coil. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Found Contactor Points Pitted And Charred. Replaced Contactor And Checked System Refrigerant Levels. Unit Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
LaPorte, IN
07-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Poor A/C. Client Had Suspicions Of Indoor Blower Problem. Found Failed Single Run Capacitor For Indoor Blower Motor. Replaced Capacitor And Checked Unit Amp Draws. Checked System Refrigerant Charge And Unit Is Cooling Properly At This Time With A Temperature Drop Of 16°.
LaPorte, IN
07-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated Rinnai R75lsi. Ran Unit Upon Arrival And Unit Displayed Error Code 10. Error Code Signifies Venting Issue. Removed Inducer And Found Many Bugs. Cleaned Inducer Wheel And Reinstalled. Removed And Check Vent. Found Exchanger To Be Corroded Suspect Exchanger Is Failed. Documented Observed Corrosion With Photographs On Work Order. Recommend Replacement Of Unit.
LaPorte, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed Two Handle Faucet Repair On MasterPlumber Kitchen Faucet. Replaced Internal Components, Cleaned And Greased All Contact Points. Tested Repair.
LaPorte, IN
07-27-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Installed New 50 Gallon Bradford White Water Heater With Power Vent. Model: Rg1pv50s6n19 Serial : Wf45334084 Filled And Cycled Unit. Set Temperature On Gas Control Valve To “hot” Setting.
LaPorte, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Disassembled Aerator On Faucet And Cleaned. Installed New O Ring To Stop Leaking. Tested Operation Of Repair By Cycling Faucet With No Leaks And Proper Pressure At This Time.
LAPORTE, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Leak Below Stop Valve On Cold Side Feed To Kitchen Sink Faucet. Removed Section Of 1/2” Copper Piping. Installed New Section Of Pipe And Stop Valve With Supply. Pressurized And Tested Replacement.
LAPORTE, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Client Stated She Is Intermittently Getting Hot Water When Showering. Inspected Tankless And Observed Proper Operation With Kitchen Sink Running. Ran Shower And Observed Low Flow Through Shower Head. Inspected Water Heater And Observed When Well Water Pressure Declined To 30 Psi Just Before Engaging Pump The Flow Rate Declined To A Rate Unable To Trigger Tankless To Engage. Cleaned Shower Head Inlet Screen And Cycled . Observed With Better Pressure Through Shower Head, Tankless Operating Properly.
LAPORTE, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Sink Ho,ding Water. Augered 30’ Out Multiple Times To Clear Sludge And Grease Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Hot Water With No Issues At This Time.
LAPORTE, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
SEWAGE PIT AND PUMP INSTALL: Scope: Remove And Dispose Of Existing Concrete In The Area Of The Proposed Pit Location. Hand Excavate Soil As Needed. Install Client Provided Sump Pit. Install Client Provided Sump Pump With A New 1-1/2 Inch Silent Check Valve. Provide And Install Appropriate Discharge Piping For The New Pump System. Replace Concrete Where Removed. Install Client Provided Laundry Tub Over The New Sump Pit And Install A New Laundry Tub Drain Into The New Sump Pit. Repair Existing 2 Inch Drain Line Where The Softener Discharge And Furnace Condensate Have Been Drilled Into The Pipe. Extend Softener Drain And Condensate Drain Into The Laundry Tub As Before. Test Installations
LaPorte, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Second Floor Bathroom Tub Not Able To Drain. Used Drill Auger To Auger Multiple Times To Clear Obstructions. Believe Clients Waste And Overflow Has Drum Trap . Unable To Tell For Sure Unless Ceiling Is Opened. Client Denied Ceiling Being Opened To Replace With New Waste And Overflow. Cycled Large Amounts Of Water With Drain Still Slow. Plunged Tub Drain Multiple Times To Clear Obstructions. Tub Drain Now Draining Properly . Cycled Large Amounts Of Hot Water With No Issues . Informed Client Of Findings.
LaPorte, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Sink Unable To Drain. Ran Drill Auger 20’ Multiple Times To Clear Obstructions. Also Ran Auger From Downstairs Up Towards Kitchen Drain Through 2” Clean Out By Laundry Tub. Tested Operation Of Repair By Cycling Large Amounts Of Hot Water And Observing Proper Drainage At This Time.
LaPorte, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Provided And Installed One APCO-X UV Assembly Above Bryant HVAC Evaporator Coil. Tested New UV Light To Ensure Proper Operation. Replaced Water Heater Venting From Water Heater To B-vent Double Wall Piping, Re-assembled The Return Air Drop And Repaired One Bathroom Supply Branch Run.
LAPORTE, IN
07-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed A/C Service And Clean. Inspected Indoor Blower Wheel, Evaporator Coil, Air Filter And Checked For Proper Airflow. Water Washed Outdoor Condenser Coil, And Tested For Proper Charge. System Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
LaPorte, IN
07-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Augered Lavatory Drain In Master Bathroom Many Times. Found Line To Contain Large Amount Of Sludge Build Up. Ran Water And Found Lavatory In Half Bath To Fill Up When Master Bath Lav Is Used. Unable To Clear Obstructions In Piping Due To How Drainage Installed. Installed New Delta Lavatory Faucet With Pop Up Assembly In Master Bathroom. Installed New Pop Up Assembly In Half Bathroom. Tested Both Installations. Recommend Removing Sections Of Wall In Half Bath To Determine Piping Layout For Lavatories, And Re Route To Accommodate Maintenance Of Drains. Returned And Camera Inspected Sewer Line Through Vent Stack. Found Double Offset In 4” Cast Iron Piping Obstructed With Tree Debris. Cleared Debris And Obserflow Through Through Lavatory Drain.
LaPorte, IN
07-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Water Leaking Into Basement When Master Shower Is Ran. Found Tile And Grouting To Be Issue. Informed Client Of Findings. Inspected Shut Off Valve Underneath Kitchen Sink. Quoted Replacement Of Single Shut Off Valve. Client Denied At This Time.
LaPorte, IN
07-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed Client Supplied Toilet And Tested Operation Of Installation By Cycling Toilet Multiple Times With No Issues. Found Failed 3/4” Galvanized Piping Over Water Heater. Replaced 10’ Section Of 3/4” Piping With New L Type Copper And Appropriate Fittings. Installed Boiler Drain For Washer On Hot Side Line That Was Being Replaced.
LaPorte, IN
07-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Installed Two Customer Supplied American Standard Toilets. Tested Operation Of Installations By Cycling Toilets Multiple Times With No Issues.
LaPorte, IN
07-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Both Basket Strainers Failed And Under Sink Drainage Leaking. Replaced Both Strainers And Under Sink Piping. Tested Operation.
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed And Disposed Of Existing Toilet And Flushometer. Installed New Ada Approved Toilet And New Flushometer.
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected All Indoor Airflow. Found System Without A Spot For An Air Filter And Furnace Blower Wheel Dirty. After Further Investigation Found Failed Condenser Fan Motor. Removed Motor And Attempted To Remove Motor Fan Blade Without Success. Need To Call Client With Pricing And Availability For A Replacement Fan Blade As Soon As Possible. Replaced Fan Motor On 7/18/2020
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Signs Of Moisture Damage On Underside Of Wall Mounted Toilet On Drywall. Pulled Toilet And Found Failed Wax Seal. Installed New Wall Toilet Gasket And Re Installed Toilet. Cycled To Test Operation. Caulked Around Toilet.
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Aged Steel Well Tank. Client Would Like Quote For Well Tank Replacement. Quoted And Replaced Old Well Tank With New Well Mate 9, Proper Fittings, Gage, And Switch. Tested Installation By Cycling Well On And Observing For Leaks And Proper Operation. Found When Well Tank Satisfies There Is A Slow Leak In Pressure. Checked To Make Sure All Fixtures Are Off And No Water Is Running Through At Toilets. Still Observed Slow Pressure Drop At Gage. Infomed Client To Contact Well Company To Have Well Inspected. Installed New ADA Right Height Elongated Bowl Toilet. Tested Operation Of Installation By Cycling Toilet Multiple Times With No Issues.
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Standing Water In Double Bay Kitchen Sink. Disassembled P Trap And Augered 20’ Out Multiple Times To Clear Obstructions. Re Assembled P Trap And Ran Large Amounts Of Hot Water With No Issues And Observed Proper Drainage At This Time. Quoted New Kitchen Faucet And Lav Faucet. Will Need To Shut Water Off At Main In Order To Replace Both Faucets. Client Did Not Want Us Down In Basement To Turn Water Off To Home. Client Will Call Back When They Have A Chance To Turn Water Off Themselves.
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Urinal Not Draining Upon Flushing. Removed Urinal And Augered 15' To Clear Drainage Obstructions. Reset Urinal And Tested Operation Of Repair By Cycling Urinal Multiple Times With No Issues.
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Service Boiler System. Cleaned Burners, Cleaned Thermocouple And Pilot Assembly, Inspected Expansion Tank, Tested Relief Valve And Reducing Valve And Cycled System To Ensure Proper Operation. Ensured All Boiler Drains Were Leak Free And Observed Unit Cycle Off At 180° With A Pressure Of Approximately 22 PSIG.
LaPorte, IN
07-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
GENERAL PLUMBING / PIPING REPAIR: Scope Swap Washer Dryer Locations. Install New Support For Existing 2 Inch Washing Machine Drain. Provide And Install New 1/2 Black Iron Gas Piping As Needed For The Gas Clothes Dryer. Provide And Install New Aluminium Dryer Vent To The Existing Vent Termination. Make Final Connections For Both Appliances. Repair Water Leak On The Existing Refrigerator Ice Maker Line. Line Is Leaking At The Sweat Joint Of The 1/2 Ball Valve.
LaPorte, IN
07-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Section Of Failed 3/4” Galvanized Piping And One Failed Hose Faucet . Removed And Replaced With 20’ Of L Type 3/4” Copper Piping. Installed One New Hose Faucet. Tested Operation Of Repairs By Pressurizing Home And Checking For Leaks. No Issues At This Time.
LaPorte, IN
07-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Fill Valve In Briggs Toilet From 1992. Informed Client Of Age Of Toilet And Findings. Conducted Toilet Rebuild. Tested Operation Of Repair By Cycling Toilet Multiple Times. Upon Cycling Observed Multiple Leaks From Tank To Bowl Gasket And At Wax Ring. Suggested New Toilet. Installed New ADA Elongated American Standard Toilet With Open Front Commercial Toilet Seat. Tested Operation Of Installation By Cycling Toilet Multiple Times With No Issues. Inspected Female Toilets Per Client Request. Found One Round Front Short Briggs Toilet From 1992 And One Elongated Front Right Height Toilet Also From 1992. Cycled Both Toilets Multiple Times. Observed No Leaks Or Issues At This Time.
LaPorte, IN
07-17-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Install Client Provided Toilet: Remove And Dispose Of Existing Toilet. Install Client Provided Toilet With A New Wax Seal And Supply Line. Flange Replacement, And Or Stop Valve Replacement Not Included.
LaPorte, IN
07-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Service Boiler System And Search For A Gas Leak. Upon Arrival Searched All Gas Fittings In The Home And Found Leak At Old Abandoned Gas Stove. Abandoned Gas Stove And All Supply Piping With A Cap At The Main Branch. Re-lit All Gas Appliances And Checked For Leaks. Serviced The Boiler System. Drained Expansion Tank, Oiled Circulator Pump, Cleaned Burners, Replaced Thermocouple, Replaced Relief Valve And Cycled Boiler To Ensure Proper Operation. System Is Heating Properly At This Time And Cycles Off At 180° With A Pressure Of Approximately 15 PSIG. Recommend Having Boiler System Serviced Annually For Preventative Maintenance Purposes.
LaPorte, IN
07-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes:Removed Section Of 3/4” Soft Copper Tubing From Crawlspace To Meter Location. Installed New 3/4” L Copper Piping With New Ballvalve From Crawlspace To Meter.
LaPorte, IN
07-16-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Augered Bath Tub Drainage. Cleared Obstructions And Observed Proper Drainage.
LaPorte, IN
07-16-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated And Found Bottom Element On Bradford White 40 GaL Electric Water Heater From 2008 Failed. Replaced Both Stats And Elements. Removed As Much Lime Scale On Bottom Of Water Heater As Possible. Re Filled Water Heater And Tested Operation Of Repair By Cycling Water Heater Through Proper Operation.
LaPorte, IN
07-16-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Standing Water In Kitchen Sink. Cycled Garbage Disposal Once And Water In Sink Started To Drain. Observed Proper Drainage In Sink At This Time. Cycled Large Amounts Of Hot Water With No Issues. Informed Client Of Back Pitched Drainage Line Downstairs. Provided Estimate For Drainage Line Replacement.
LaPorte, IN
07-16-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana

LaPorte, IN
07-16-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Poor A/C. Upon Arrival Inspected All Indoor Airflow. After Further Investigation Found System Low On R-22 Refrigerant. Due To The Systems Eighteen Years Of Age, A Known Leak In The System And Phased Out Refrigerant, Client Requests An Estimate For A Replacement A/C System. Gathered Information To Provide And Estimate For Replacement. Proposal Will Be Emailed When Completed.
LaPorte, IN
07-16-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Client Had Removed Existing Sump Pump Before Arrival. Installed New Zoeller Sump Pump And Pvc Quiet Check Valve. Cycled Unit To Test Operation.
LAPORTE, IN
07-13-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Blower Wheel, Evaporator Coil And Air Filter. Cleared Drain Line, Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Cycled Unit From The Thermostat And Checked System Refrigerant Charge. Unit Is Cooling Properly At This Time With A Temperature Drop Of 18 Degrees Across The Evaporator Coil.
LaPorte, IN
07-13-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Lav Drain To Be In Good Working Order. Inspected Tub Shower Drain And Found Overflow Stopper Stuck In Down Position. Disassembled Overflow And Removed Stopper. Observed Proper Flow Of Tub Drain At This Time . Informed Client Of Findings And Quoted New Waste And Overflow Due To No Stopper In Existing Overflow Anymore.
LAPORTE, IN
07-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Poor Air Conditioning In The Main Area Of The Home. Upon Arrival Client Explained That Two New Air Conditioning Systems Had Recently Been Installed By A Different Company And The Master Bedroom System Seemed To Be Cooling Well. After Further Investigation Both New Systems To Be Sized Identically In Cooling Capacity. Found The Main Area Of The Home To Be Roughly 2000 Square Feet And The Equipment Undersized. Found Variable Speed Fan Selections For Both Pieces Of Equipment To Incorrect. Adjusted Master Bedroom System For Approximately 800 CFM Of Air And Did No Changes To The Main System Due To Its Lack Of Cooling Capacity. Also Found Kitchen/dining Room Zone Damper Failed. Client Requests Estimates For Replacement Air Conditioning Systems For Both Areas Of The Home. Client Will Receive The Proposals Via E-mail When Completed.
LaPorte, IN
07-10-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Leak On Copper Piping To Hot Side Of Washer Box. Removed Section And Replaced . Pressurized And Inspected Repair.
LAPORTE, IN
07-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Southern A/c System Per USP Plan Requirements. Inspected Blower Wheel, Evaporator Coil And Replaced Client Provided Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Ensured System Operates In Both Stages Of Cooling And Checked System Refrigerant Levels. Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LaPorte, IN
07-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Poor Cooling. Upon Arrival Inspected All Indoor Airflow. Replaced Air Filter And Checked System Refrigerant Levels. Found Unit Low On R-22 Refrigerant. Added Up To 1# Of R-22 Refrigerant And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil. Client Plans To Replace The A/C System Next Season.
LAPORTE, IN
07-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Septic Tank Lid And Observed Blockage At Entry Point Of Septic. Informed Client Septic Is Full And Needs To Be Pumped In Order For Drainage To Work Correctly.
LaPorte, IN
07-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected All Indoor Airflow And Found Failed Dual Run Capacitor In Outdoor Condensing Unit. Replaced Capacitor And Checked Compressor And Fan Motor Amp Draws. Found Contactor Points Pitted And Charred; No Action Taken. Cycled System And Checked For Proper Refrigerant Levels. Unit Is Cooling Properly At This Time With A Temperature Drop Of 21 Degrees Across The Evaporator Coil.
LaPorte, IN
07-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced Furnace And A/C Systems. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 78 Ohms, Cleaned Inducer Signal Port, Inspected Blower Wheel, Inspected Evaporator Coil And Replaced Air Filter. Also Inspected Primary Heat Exchanger Cells With No Failures At This Time. Found Inducer Motor With Noisy Bearings And Vent Piping Starting To Show Signs Of Fatigue. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 66°. Also Serviced A/C System. Inspected All Indoor Airflow, Water Washed Outdoor Condenser Coil And Replaced Failed Capacitor. Cycled System And Found Unit Low On R-22 Refrigerant. Added Up To 1# Of R-22 Refrigerant And Unit Is Cooling Properly With A Temperature Drop Of 16° Across The Evaporator Coil. Created An Estimate For A Replacement Inducer Motor And New Vent Piping. Client Would Like The Motor And Vent Piping To Be Replaced And An Appointment Made In The Fall. Client Would Like A Paper Receipt.
LaPorte, IN
07-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Investigated And Found Under Slab Sewer Line Obstruction Causing Backing Up. Camera Inspected And Found Soft Blockage In Piping. Augered Line To Clear Build Up.
LaPorte, IN
07-08-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Inspected Blower Wheel, Evaporator Coil And Air Filter. Test For Proper Airflow, Condensate Pump Cycled Properly During Visit. Water Washed Outdoor Condenser Coil, Tested All Electrical Components And Checked For Proper Charge Of System. System Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil.
LAPORTE, IN
07-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Callback For Water Around Furnace. Upon Arrival Removed Evaporator Coil And Cleaned All Remaining Water In And Around Drain Pan. After Further Investigation Found System Low On R-22 Refrigerant. Added Up To 1# Of R-22 And System Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil. Suspect System To Have Froze Due To Low Refrigerant And The Dirty Air Filter Removed On 6-30-20. The Remaining Condensate Water Beneath The Drain Pan Had Continued To Leak Onto The Floor In Conjunction With The Plugged Condensate Line Found On 6-30-20.
LAPORTE, IN
07-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Kitchen Faucet With New Customer Supplied Kitchen Faucet. Tested Operation Of Installation By Cycling Water Through Faucet And Checking For Leaks. No Issues At This Time.
LAPORTE, IN
07-02-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Failed Hose Faucet And Replaced With New Wolverine Brass Hose Faucet. Tested Operation Of Installation By Pressurizing, Checking For Leaks At Connections, And Cycling Faucet With No Issues At This Time.
LAPORTE, IN
07-02-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C In Bedroom Zone. Upon Arrival Found Outdoor Condenser Unit In To High Pressure Condition. After Further Investigation Found Failed Condenser Fan Motor. Replaced Condenser Fan Motor And Cycled Unit To Ensure Proper Operation. Unit Is Cooling Properly At This Time With A Temperature Drop Of 21 Degrees Across The Evaporator Coil.
LaPorte, IN
06-29-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Replaced Two Boiler Drains Serving Washing Machine.
LAPORTE, IN
06-29-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Turned Saddle Valve Off To Ice Maker In Basement. Unable To Test Due To Pets. Will Return On Later Date When Animals Are Secured. Upon Re Arrival Attached Existing Copper Line To Fridge. Tested Operation Of Shut Off Valve In Basement Found No Issues At This Time With Shut Off Valve Supplying Ice Maker Line. Tested Operation Of Attachment Of Ice Maker Line With No Leaks Or Issues At This Time.
LaPorte, IN
06-29-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Leak In Ceiling. Found Shower Drain Leaking When Used. Drywall Ceiling Damage Throughout Entirety Of Living Room And Portion Of Kitchen. Also Found Floor Damage From Where Leak Broke Through Ceiling And Seeped Into Basement Through Flooring. Informed Client Of Findings. Replaced 2” Shower Drain Along With 2” P Trap. Re Attached To Existing Pvc Piping. After Letting Glue Dry Tested Operation Of Repair By Cycling Large Amounts Of Water Through Shower With No Issues .
LaPorte, IN
06-29-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP A/C Service Per Plan Requirements , Checked Blower Wheel, Checked Evaporator Coil, Inspected Air Filter, Washed Outdoor Condenser Coil, Checked All Electrical Components, Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LAPORTE, IN
06-29-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Existing Washer Valves And Replaced With Two New Washer Valves. Tested Operation Of Installation By Pressurizing And Checking For Leaks With No Issues. Installed New Riser Pipe In L Type 1/2” Copper For Bathroom Tub Shower. Client Had Opened Wall Previous To Our Visit. Unable To Test Operation Of Installation Due To Client Not Having Tub Spout Or Trim Kit Installed At This Time.
LaPorte, IN
06-25-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes:Upon Arrival Found Hose Faucet Leaking At Handle And Into Home. Removed Section Of Drywall To Access Hose Faucet. Replaced With New Wolverine Brass Hose Faucet. Re Attached To Existing Copper Line. Re Pressurized Home And Tested Operation Of Installation By Cycling Water Through Hose Faucet With No Issues. Informed Client The Hose She Is Using Needs To Be Replaced As Well .
LaPorte, IN
06-25-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Cleaned Aerator On Customer Faucet Switched Hot And Cold Lines So That Hot Is On Left. Tested Operation Of Repair By Cycling Water With No Issues. Informed Client Of Broken Handle On Hot Side Stop Valve. Clients Did Not Want To Replace At This Time. Informed Client Of Where Whole House Water Shut Off Is Located.
LaPorte, IN
06-25-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Blower Wheel, Evaporator Coil And Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Cycled System From The Thermostat And Checked Unit Refrigerant Charge. Found System Low On R-22 Refrigerant. Client Declined Adding Refrigerant At This Time. Unit Is Operating At This Time With A Temperature Drop Of 14° Across The Evaporator Coil.
LAPORTE, IN
06-25-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Installed Client Provided Lavatory Cabinet And Top. Installed Client Provided Lavatory Faucet. Installed New Drainage And Supply To Faucet.
LaPorte, IN
06-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Fill Valve. Replaced Fill Valve And Supply Line Discounted Price Due To Flush Tower Being In Good Condition And Needing No Work Done. Tested Operation Of Installation By Cycling Toilet Multiple Times With No Issues.
LAPORTE, IN
06-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Investigated Leak Around Furnace And Found Condensate Line Unable To Drain Due To Minor Obstructions. Used Compressed Air To Clear Condensate Line. Tested Operation Of Repair By Cycling Water Through Line With No Issues.
LaPorte, IN
06-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Installed New 1” Blk Tee In Main Gas Line In Basement. Installed New 1” Gas Piping To Outdoors At Specified Location For Future Use. Capped Line And Pressurized. Leak Tested Fittings. Relocated Hose New Faucet To The Right Of Previous Location To Accommodate New Gas Meter. Pressurized And Inspected.
LaPorte, IN
06-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Leak In Crawl Space When Lavatory Sink Ran. Found Failed 1 1/2” Copper Piping. Replaced Section With New 1 1/2” Pvc And Fittings. Attached Onto Existing Piping. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues.
LaPorte, IN
06-22-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Found Kitchen Sink Draining Slowly. Augered Out 30’ Multiple Times To Clear Food Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Hot Water With No Issues And Observing Proper Drainage At This Time.
LaPorte, IN
06-18-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Cycled Unit From The Thermostat And Checked System Refrigerant Charge. Unit Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil.
LaPorte, IN
06-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Failed Laundry Tub Faucet And Installed New Customer Supplied Delta Faucet With Spray. Tested Operation Of Installation By Cycling Water Through Appliance And Checking For Leaks. No Issues At This Time.
LaPorte, IN
06-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Poor A/C. Upon Arrival Inspected Indoor Blower Wheel, Evaporator Coil And Replaced Air Filter. Inspected Outdoor Condensing Unit And Found Unit Low On R-22 Refrigerant. Added Up To 1# Of R-22 And System Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil. Recommend Having The Air Conditioning System Serviced Annually. Client Would Like A Paper Receipt.
LaPorte, IN
06-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Service Two A/C Systems And Diagnose Poor Cooling From Main System. Upon Arrival Inspected All Indoor Airflow. Inspected Blower Wheels, Evaporator Coils And Replaced Air Filters. Water Washed Outdoor Condenser Coils And Inspected All Electrical Components. Found Main System Dual Capacitor Weak Causing Outdoor Fan Motor To Short Cycle On Internal Overload. Also Found Bedroom System Capacitor Weak. Replaced Both Capacitors And Cycled Units To Ensure Proper Operation. Found Main System Low On R-22 Refrigerant. Added Up To 1# Of R-22 To Main System And Both Systems Are Cooling Properly At This Time With Temperature Drops Of 16° Across The Evaporator Coil.
LaPorte, IN
06-15-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP A/C Service. Inspected Blower Wheel, Evaporator Coil And Replaced Air Filter. Water Washed Condenser Coil And Inspected All Electrical Components. Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 18 Degrees Across The Evaporator Coil.
LaPorte, IN
06-15-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Toilet Bowl Full Of Waste Material. Augered With Toilet Auger To Clear Obstructions. Cleared Obstruction And Cycled Toilet To Test Operation.
LaPorte, IN
06-15-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Water Leaking From Attic A/C System. Upon Arrival Found Condensate Pan Full And Condensate Piping Clogged. Cleared Drain Line And Inspected All Indoor Airflow. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Replaced Weak Dual Capacitor Per Clients Request. Checked System Refrigerant Levels And Added Up To 1# Of R-22 Refrigerant. System Is Cooling At This Time With A Temperature Drop Of 22 Degrees Across The Evaporator Coil. Recommend Replacing Pleated Air Filter With A Fiberglass Style Filter.
LaPorte, IN
06-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Replaced Water Heater Under Manufacturer Warranty. Installed New 3/4” Ball Valve Per Client Request. Filled And Cycled Unit. Set Temperature On Gas Control Valve To “hot” Setting. Model RG240T6N Serial TF43605947
LaPorte, IN
06-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP A/c Service Per Plan Requirements. Inspected Evaporator Coil, Blower Wheel And Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Checked System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LaPorte, IN
06-12-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Installed Client Provided Toilet. Unable To Perform Lavatory Installation Due To Broken Top. Client Will Contact To Schedule Installation When New Top Acquired.
LaPorte, IN
06-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes:camera Inspected Line From Home To Yard Trap. Found No Root Intrusion And A Slight Soft Blockage. Augered Line Through Yard Trap To City Main. Removed Roots From Sewer
LaPorte, IN
06-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Echnician Invoice Notes: Upon Arrival Investigated Water In Crawl Space When Toilet Flushed And Found Failed 3” Copper Fitting Failed. Cut Out Failed Fitting And Replaced With New Pvc Fittings. Reattached To Existing Copper Drainage And Tested Operation By Cycling Toilet Multiple Times And Checking For Leaks With No Issues.
LaPorte, IN
06-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Our Ultimate Service Plan Includes Huge Discounts And Savings On All Of The Repairs And Installations That We Perform Every Day For Heating, Air Conditioning, And Plumbing. Whether It’s A New Enhancement Or Repair, We Have The Right Products And Solutions. As Part Of The Program, We Include Priority Service Guaranteed. Plus, You Can Save Even More During Business Hours.
LaPorte, IN
06-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Performed USP A\C Service Per Plan Requirements. Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Washable Air Filter. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Cycled Unit And Checked System Refrigerant Charge. System Is Cooling Properly At This Time With A Temperature Drop Of 20° Across The Evaporator Coil.
LaPorte, IN
06-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Toilet Obstruction Causing Overflow. Augered Toilet And Cleared Obstruction. Tested Toilet Operation.
LaPorte, IN
06-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Well Tank Bladder Failed. Drained And Disposed Of Existing Tank . Installed New Well Mate 9 M:WM-9QUICKCONNECT S:070205288 Pressurized System And Tested Operation.
LaPorte, IN
06-09-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Client Water Heater With New Bradford White 50 Gal Standard Vent Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps. When Dreaming Water Heater Sump Pump Failed. Replaced Sump Pump With New Zoeller Sump Pump. Tested Operation Of Installation By Cycling Sump Pump Multiple Times With No Issues.
LaPorte, IN
06-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found Failed Blower Motor. After Further Investigation Found Blower Wheel Extremely Dirty And Air Filter Plugged. Replaced Client Provided Air Filter. Cleaned Blower Wheel, Replaced Blower Motor And Single Run Capacitor. Cycled Unit And Checked For Proper Refrigerant Levels. System Is Cooling Properly At This Time With A Temperature Drop Of 19 Degrees Across The Evaporator Coil.
LaPorte, IN
06-08-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes:Augered Lavatory Sink Drain. Filled Sink Twice To Test Drain Operation.
LaPorte, IN
06-08-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Sink Disposal Not Functioning Correctly. Reset Disposal And Used Allen Wrench To Break Free Build Up In Disposal. Tested Operation Of Repair By Cycling Disposal With Large Amounts Of Water With No Issues. Informed Client Of Findings And Age Of Disposal.
LaPorte, IN
06-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Broken Toilet And Replaced With Customer Supplied Eljer Toilet. Tested Operation Of Installation By Cycling Toilet Multiple Times. All In Good Order.
LaPorte, IN
06-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Broken Waste And Overflow, Client Also Wanted Shower Valve Replacement. Upon Further Investigation Of Access Panel Advised Client Much More Drywall And Part Of His Stairwell Ceiling Would Have To Be Removed In Order To Replace Shower Valve. Client Denied Shower Valve Replacement At This Time. Removed Copper Waste And Over Flow And Replaced With New Pvc Waste And Overflow. Tested Operation By Cycling Large Amounts Of Water While Observing Proper Flow With No Leaks.
LaPorte, IN
06-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INVOICE NOTE: Technician Invoice Notes: Upon Arrival Found Leaking Tub Faucet And Failed Tub Shoe. Replaced Delta Tub Faucet Cartridge With New Delta Tub Faucet Cartridge. Tested Operation Of Installation By Cycling Water And Testing For Drips. Replaced Waste And Overflow So Client Can Have Proper Tub Stopper. Tested Operation Of Installation By Cycling Water While Observing Proper Operation.
LaPorte, IN
06-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Blower Wheel, Inspected EAC And Inspected Evaporator Coil. Water Washed Outdoor Condenser Coil And Inspected All Electrical Components. Replaced Capacitor Due To Weak Capacitance Measurements. Cycled Unit And Checked System Refrigerant Charge. Unit Is Cooling Properly At This Time With A Temperature Drop Of 18° Across The Evaporator Coil.
LAPORTE, IN
06-05-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated Gas Smell. Leak Tested All Gas Piping Near Location Of Odor. Found Leak On 3/4” Union. Tightened Union And Re Inspected. Found No Other Leaks At This Time In Area.
LaPorte, IN
06-03-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced 50 Gal Electric Water Heater With New Bradford White 40 Gal Electric Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
06-03-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Replaced Two Hose Faucets. Rebuilt Modern Leg Tub Faucet. Tested Repairs.
LaPorte, IN
05-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found High Pressure Switch Tripped. After Further Investigation Found Fan Speed Set Incorrectly And A/C System Overcharged. Re-adjusted Fan Speed And Removed Approximately Two Pounds Of Of R410-A Refrigerant. Cycled System To Ensure Proper Operation And Unit Is Cooling Properly At This Time With A Temperature Drop Of 16° Across The Evaporator Coil.
LaPorte, IN
05-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected Blower Wheel, Evaporator Coil And Air Filter. After Further Investigation Found Failed Contactor In Outdoor Condenser. Replaced Contactor And Checked System Refrigerant Levels. Unit Is Cooling Properly At This Time With Drop Of 19 Degrees Across The Evaporator Coil. Recommended Considering Replacement Of The Air Conditioning System Due To Its Age.
LaPorte, IN
05-28-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed And Disposed Of Existing Water Heater. Installed New 40 Gallon Bradford White Water Heater With Atmospheric Vent. Model Number : RG240T6N Serial Number: TJ43914522 Filled Unit And Cycled. Set Temperature On Gas Control Valve To “hot” Setting. Checked Operation.
LaPorte, IN
05-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Found Failed Fan Capacitor On Outdoor Unit. Installed New Capacitor. Fan Motor Bearing Are Very Noisy. Compressor Is Very Noisy On Start Up And System Is Slightly Low On Refrigerant. Client Would Like Estimate To Replace The System.
LaPorte, IN
05-27-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed Existing Water Heater And Installed Client Supplied A.O. Smith 50 Gal Power Vent Water Heater. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
05-26-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Toilet Unable To Flush Due To Sewage Line Holding Water, Found Water Heater Failed And Will Need 50 Gal Power Vent Bradford White Natural Gas Water Heater. Augered Sewage Line Out 10’ From Outside Clean Out To Clear Waste Paper, Baby Wipes And Waste Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Water. Installed New 50 Gal Power Vent Bradford White Water Heater . Attached To Existing Piping And Existing Re Circulation Line. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
05-26-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Existing Water Heater And Replaced With New Bradford White 50 Gal Standard Vent. Tested Operation Of Installation By Cycling Water Heater Through Proper Steps.
LaPorte, IN
05-26-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Unable To Re Create Gurgling In Kitchen Sink, Also Found Laundry Tub Holding Water When Laundry Machine Discharge Was In Use. Pulled 2” Clean Out Cap And Augered 30’ With D100 To Clear Line Obstructions. Kitchen Drainage Line Attaches To Laundry Discharge Line. Tested Operation Of Repair By Cycling Large Amounts Of Water Through Laundry Machine And Laundry Tub With No Issues At This Time.
LaPorte, IN
05-26-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Replaced Existing 30 Year Old Water Heater. Installed New Bradford White 40 Gallon Water Heater. Model Number RG240T6N Serial Number WC44871571. Filled And Cycled Unit. Set Temperature On Gas Control Valve To “hot” Setting. Inspected Operation.
LaPorte, IN
05-26-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Disposal Failed. Client Chose To Remove Unit And Have Basket Strainer Installed. Installed New Basket Strainer And Trap Assembly. Ran Water Nd Tested Operation.
LaPorte, IN
05-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Observed Lavatory Drain Holding Water. Disassembled And Attempted To Auger. 1 1/2” Galvanized Elbow Severely Rotted And Leaking. Replaced 2’ Section Of Galvanized Drainage Piping With New 1 1/2” Pvc Piping And Fittings. Augered Drain And Cleared Obstructions. Tested Operation Of Lav Drain By Cycling Large Amounts Of Hot Water With No Issues. Cleaned Hair Obstructions In Tub Drain And Tested Operation By Cycling Large Amounts Of Hot Water With No Issues.
LaPorte, IN
05-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Started A/C System As Part Of HVAC Contract Installation. Adjusted Indoor Blower Speed For 1000 CFM And Adjusted Refrigerant Charge With An Additional 10 OZ Of R-410A Refrigerant. Filled Condensate Pump To Ensure Proper Operation And System Is Cooling Properly With A Temperature Drop Of 16 Degrees Across The Evaporator Coil.
LaPorte, IN
05-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Started A/C System As Part Of HVAC Contract Installation. Adjusted Indoor Blower Speed For 1000 CFM And Adjusted Refrigerant Charge With An Additional 10 OZ Of R-410A Refrigerant. Filled Condensate Pump To Ensure Proper Operation And System Is Cooling Properly With A Temperature Drop Of 16 Degrees Across The Evaporator Coil.
LaPorte, IN
05-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes:Call To Service A/C System. Inspected Blower Wheel, Inspected Evaporator Coil, Inspected Air Filter, Water Washed Outdoor Condenser Coil, Inspected All Electrical Components And Cycled System To Ensure Proper Operation. Inspected System Refrigerant Levels And Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil. Client Would Like A Paper Receipt.
LaPorte, IN
05-20-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call To Service A/C System. Inspected Blower Wheel, Evaporator Coil And Replaced Client Supplied Air Filter. Water Outdoor Condenser Unit, Inspected All Electrical Components And Found Dual Capacitor Measuring Lower Than Factory Recommended Capacitance For The Outdoor Fan Motor. Client Declined Replacement Of The Capacitor At This Time. Cycled Unit, Measured All Amp Draws Within Specifications And Checked System Refrigerant Levels. Unit Is Operating Properly At This Time With A Temperature Drop Of 16 Degrees Across The Evaporator Coil.
LaPorte, IN
05-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed And Replaced Basket Strainer In Single Bay Hand Washing Sink. Replaced Safety Valve On Water Heater. Client Denied Full Flush And Tune So Adjusted Price Is Just For Replacement Of Safety Valve. Installed New Supplied ADA Round Bowl Toilet With Supplied Open Face Toilet Seat. Installed Repair Flange Before Setting Toilet. Will Return For Replacement Of Expansion Tank.
LaPorte, IN
05-20-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Septic Tank Operating Properly And Proper Flow To Tank. Investigated First Toilet And Observed Sluggish Flush. Augered Through Toilet And Still Observed Slow Flush. Suspect Trapway Obstructions Due To Large Amount Of Hardness Buildup In Bowl Into Trapway. Investigated Second Toilet And Found Broken Fill Valve Causing Water On Floor. Replaced Toilet Tank Components And Tested By Flushing Many Times.
LaPorte, IN
05-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Determined Sewer Obstruction Causing Backing Up Into Basement. Augered Main From Grease Trap To Yard Trap. Then From Yard Trap To City Main. Camera Inspected From Grease Trap To Yard Trap And Found Line Open And Operating. Unable To Camera Inspect Through Yard Trap.
LaPorte, IN
05-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Serviced A/C System. Inspected Evaporator Coil, Replaced Client Supplied Air Filter, Inspected Blower Wheel, Water Washed Condenser Coil And Inspected All Electrical Components. Cycled Unit And Checked For Proper Refrigerant Levels. Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LaPorte, IN
05-18-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found 1/2” Galvanized Pipe Nipples Rusted At 1/2 X 3/8 Adaptation. Removed And Installed New Stop Valves To Eliminate Failed Piping.
LaPorte, IN
05-13-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Sewer System Not Draining. Augered Out 100’ To Clear Root Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues. Pulled And Reset Toilet By Kitchen To Access 3” Sewer Drainage Line.
LaPorte, IN
05-13-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Removed Existing Hose Faucets (2), And Replaced With Two New Wolverine Brass Hose Faucets. Attached To Existing Piping And Tested Operation Of Installation By Cycling Both Hose Faucets.
LaPorte, IN
05-13-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Standing Water In 3” Clean Out. Augered Out 75’ To Clear Obstructions. Found Large Amount Of Root In 6” Clay Tile Sewage Line. Informed Client Of Proper Way To Take Care Of Situation By Installing Outdoor Clean Out. Ran Large Amounts Of Water To Inspect Operation Of Sewage Line. No Issues With Drainage At This Time. Inspected Back Flow Prevention Ball And Found In Good Condition. Clean Out Plug For Floor Drain Was Non Existent. Installed 1 1/2” Plug.
LaPorte, IN
05-13-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No Heat From Boiler System. Upon Arrival Found Unit Displaying Fault Code F7 And Substantial System Pressure Difference Between Return And Supply Piping. After Further Investigation Found Domestic Recirculator Pump Partially Isolated Causing Inadequate Flow Through Heat Exchanger Assembly. Opened Valves And Cycled Boiler Through All Radiant Zones And Domestic Cycles. Unit Is Heating Properly At This Time And Cycles Off At 190° With A Pressure Of Approximately 21 PSIG.
LaPorte, IN
05-13-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Remove And Dispose Of Existing Cast Iron Bathtub And PVC Surround. Provide And Install: One Mustee 60
LaPorte, IN
05-11-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Lav Drain Plugged. Removed 4 Surgical Tools From P Trap And Augered Out 30’ To Clear Hair And Other Obstructions. Tested Operation Of Repair By Cycling Large Amounts Of Water While Observing Proper Drainage.
LaPorte, IN
05-11-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Removed Existing Silcock. Installed New Hose Faucet. Pressurized And Tested Installation.
LaPorte, IN
05-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Investigated Leaking At Base Of Toilet When Cycled. Pulled And Reset Toilet As Well As Tightening Fill Valve. Tested Operation Of Reset By Cycling Toilet Multiple Times To Check For Leaks. No Leaks At This Time. Added Pictures Of Main Cast Iron Drainage To Invoice For Possible Replacement If Issue Continues.
LaPorte, IN
05-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Replaced Previously Inspected Waste/overflow. Tested Operation.
LaPorte, IN
05-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Delta Single Handle Faucet Leaking When Used. Disassembled And Replaced Internal Components. Cleaned And Greased Friction Points And Seals. Tested Operation.
LaPorte, IN
05-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Replaced Tank To Bowl Basket And Pulled And Reset Water Closet. Tested Operation Of Repairs By Cycling Water Closet Multiple Times. Water Closet Cycling Correctly With No Leaks At This Time.
LaPorte, IN
05-07-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Replaced Freeze Damaged Hose Faucet. Pressurized And Tested Installation.
LaPorte, IN
04-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
GENERAL PLUMBING / PIPING REPAIR: Scope: Remove And Dispose Of Existing Double Vanity. Remove A Section Of Drywall As Needed To Access The Existing Supply And Drainage Piping. Provide And Install New Water Supply And Drain Lines As Needed To Supply The New Laundry Unit. Note: New Supply And Drain Piping Shall Be Mounted Exposed On The Interior Wall. Provide And Install One New 36
LaPorte, IN
04-30-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Grease Trap In Side Yard Full And Overflowing. Removed Water From Grease Trap And Observed Water Level In Neighboring Houses Grease Trap Dropping At Same Rate. Suspect Neighbor House Is On A Shared Sewer Line. Augered To Yard Trap To Clear Obstructions In Piping. Ran Large Amount Of Water And Ran Washing Machine To Test Flow.
LaPorte, IN
04-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Kitchen Sink Faucet Leaking Large Amounts Of Water Into Cabinetry When Used. Informed Client Of Findings And To Give Us A Call When New Faucet Is Chosen For Installation.
LaPorte, IN
04-17-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
GENERAL PLUMBING / PIPING REPAIR: Scope: Remove And Dispose Of Existing Basement Drainage Piping. Provide And Install New PVC Drainage Piping And Fittings As Needed To Serve The First Floor Fixtures. Provide And Install A New Drain Tree Connection At The Existing Foundation Penetration. Provide And Install A New Waste & Overflow Assembly For The Existing Bathtub. Provide And Install A New 1-1/2 Inch Silent Check Valve For The Existing Sump Pump.
LaPorte, IN
04-15-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Moisture At Base Of Wall In Kitchen Behind Refrigerator. Camera Inspected Through Small Hole But Unable To Locate Source. Camera Inspected Through Shower Valve Hole In Second Floor Bath And In Joist Space Under Shower. Unable To Locate Source. Removed Sections Of Drywall Behind Refrigerator To Identify Location Of Leak. Due To A False Ceiling Unable To Make Repairs From Kitchen Side. Removed Section Of Wall In Shower Alcove On Opposite Side Of Wall To Expose 3/4” Copper Piping Failure Location. Removed Leaking Copper Tee And Surrounding Piping. Replaced With New Copper Piping And Fittings.
LaPorte, IN
04-11-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Boiler Relief Valve Dripping. Upon Arrival Found Boiler Pressure At 20 PSIG And 180° With Evidence Of Relief Valve Leaking. Inspected Expansion Tank And Auto Fill Devices. Replaced Relief Valve And Purged Air From Boiler. Secured Bypass Handle Of Reducing Valve To Help Prevent The Possibility Of Accidental Over Pressurization Of The Boiler. Cycled Boiler To 180° And Found Unit Cycle Off At 19 PSIG. System Is Operating Properly At This Time With No Leaks Present.
LaPorte, IN
04-11-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Thermostat Calling For Heat With No Low Voltage. After Further Investigation Found Failed Transformer. Client Had Switched To A/C On The Thermostat Recently And The Furnace Never Came Back On. Found Rodent Chewed Wired At Outdoor Condenser. Repaired Low Voltage Wiring And Re-sealed Line Set Hole. Inspected Furnace Heat Exchanger And Found The Primary Cells Failed. Performed A Carbon Monoxide Test And Unit Is Emitting No Carbon Monoxide At This Time. Highly Recommended Client To Replace Furnace Due To The Potential For Carbon Monoxide Gases.
LaPorte, IN
04-11-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Basement Toilet To Have A Broken Fill Valve. Replaced Toilet Tank Components. Set Proper Water Level And Cycled To Test Operation.
LaPorte, IN
04-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Main Circulator Pump Leaking. Upon Arrival Found Failed Bearing Assembly In Main B&G Pump. Replaced Pump Assembly With New Taco Circulator And Cycled Boiler To Ensure Proper Operation. System Is Heating Properly At This Time. Recommend Having The Other Two Circulator Pumps Replaced Due To Noisy Operation And Having Boiler Serviced Annually For Preventative Maintenance Purposes.
LaPorte, IN
04-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Observed No Flow At Yard Trap In Front Yard. Augered From Yard Trap To Main With 2.5” Blade And Cleared Root And Wipe Obstructions. Pulled Main Toilet And Augered With 3” Blade To Yard Trap And Removed Large Amounts Of Root And Wipes. Attempted To Auger From Yard Trap To Main With 3” Blade. Unable To Auger With 3” Due To Separations In Piping. Tested Laundry Drain With Large Amounts Of Water. Observed Proper Drainage At Laundry Drain And Observed Flow From Yard Trap When Cycling Toilet And Laundry. Informed Client Of Findings.
LaPorte, IN
04-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Hooked Up Customer Stove And Tested For Proper Operation And Gas Leaks. No Gas Leaks And Proper Operation Of Stove At This Time.
LaPorte, IN
04-09-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
WELL MATE 9 PRESSURE TANK INCLUDES FITTINGS AND GAUGE: Provide And Install A New Well Mate 9 Pressure Tank With Near Piping, Relief Valve And Pressure Gauge.
LaPorte, IN
04-03-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Installed Client Supplied Water Closet And Removed Existing. Tested Operation By Cycling Water Closet Multiple Times.
LaPorte, IN
04-03-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Observed Outdoor Clean Out With Standing Water. When Appliances Ran Overflow At The Laundry Drain In Basement Would Occur. Augered Out Of Main Clean 30’ Multiple Times To Clear Obstructions. Attempted To Camera Line But Unable To Due To Large Separation At Clean Out Tee. Observed Good Flow At This Time When Toilets Flushed.
LaPorte, IN
04-02-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Pressure Assisted Toilet Tank Bladder Leaking At Seam Into Tank. Removed And Replaced Failed Tank. Cycled And Tested Operation.
LaPorte, IN
04-02-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Gfi Tripped For Disposal. Reset And Found Garbage Disposal To Be Working At This Time With No Issues. Client Would Not Like Installation Of New Disposer.
LaPorte, IN
04-02-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Installed New A95UH1E070B12 Armstrong Furnace, Honeywell Focus Pro 6000 Programmable Thermostat And Reme Halo LED Air Purifier Per HVAC Contract Details. Tested System Operation And Unit Is Operating Properly With A Temperature Rise Of 54°. InstlDtL Installation Details: EQUIPMENT > Armstrong High Efficiency Furnace Model A95UH1E070B12S-06 - 95% AFUE Efficiency Rating > Honeywell Focus Pro 5000 Non-programmable Thermostat SCOPE OF WORK 1. Remove And Dispose Of The Existing Furnace. 2. Install The New Furnace, Adapting To The Existing Supply And Return Air Duct Systems. 3. Connect The Furnace To The Existing Electrical Circuit, Exhaust Piping And Gas Piping. - Repair Leaking Exhaust PVC Elbow 4. Install A New Honeywell Focus Pro 5000 Thermostat In The Same Location As The Existing Thermostat. 5. Start The New Furnace And Check System Operation. Factory Warranties: All Equipment Warranties Per The Terms And Conditions Of The Manufacturer. Armstrong Equipment For This Application Qualifies For A Ten Year Limited Parts Warranty With A Limited Lifetime Parts Warranty On The Heat Exchanger. Please Review All Manufacturer Warranty Certificates For Full Details Of Warranties. Dye Plumbing & Heating Warranty: We Offer A Two Year Material And Labor Warranty For The Work Provided. This Warranty Does Not Include Standard Maintenance Procedures (annual Cleaning, Filter Changes, Etc.)
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Installation Details:EQUIPMENT:Armstrong Model: A96UH2E070B12S-01; Serial: 5919M00951 Series High Efficiency Furnace- 96% AFUE Efficiency Rating- Two Stage Operation- Stainless Steel Heat Exchangers- ECM Constant Torque Blower MotorSCOPE OF WORK:1.Remove And Dispose Of The Existing Furnace And Condensate Drain Piping.2.Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work. 3.Adapt The New Furnace To The Existing Line Voltage And Low Voltage Electrical Circuits.4. Adapt The New Furnace To The Existing Gas Supply Piping.5. Adapt The New Furnace To The Existing PVC Intake & Exhaust Vent Piping. - Terminate The Exhaust Piping Per Manufactures Instructions.6. Provide And Install New Condensate Drainage Piping From The New Furnace And Existing A/C Evaporator Coil.7. Adapt The New Furnace To The Existing Thermostat.8. Start The New Equipment And Check System Operation. - Ensure Proper Airflow Selections Have Been Made For The Cooling And Heating Cycles Of The Equipment.All Equipment Warranties Per The Terms And Conditions Of The Manufacturer. Armstrong Equipment For This Application Qualifies For A Ten Year Limited Parts Warranty With A Standard Twenty Year Parts Warranty On The Heat Exchangers. Please Review All Manufacturer Warranty Certificates For Full Details Of Warranties.Dye Plumbing & Heating Warranty: We Offer A Two Year Material And Labor Warranty For The Work Provided. This Warranty Does Not Include Standard Maintenance Procedures (annual Cleaning, Filter Changes, Etc).
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Installation Details:EQUIPMENT:Armstrong Model: A96UH2E070B12S-01; Serial: 5919M00951 Series High Efficiency Furnace- 96% AFUE Efficiency Rating- Two Stage Operation- Stainless Steel Heat Exchangers- ECM Constant Torque Blower MotorSCOPE OF WORK:1.Remove And Dispose Of The Existing Furnace And Condensate Drain Piping.2.Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work. 3.Adapt The New Furnace To The Existing Line Voltage And Low Voltage Electrical Circuits.4. Adapt The New Furnace To The Existing Gas Supply Piping.5. Adapt The New Furnace To The Existing PVC Intake & Exhaust Vent Piping. - Terminate The Exhaust Piping Per Manufactures Instructions.6. Provide And Install New Condensate Drainage Piping From The New Furnace And Existing A/C Evaporator Coil.7. Adapt The New Furnace To The Existing Thermostat.8. Start The New Equipment And Check System Operation. - Ensure Proper Airflow Selections Have Been Made For The Cooling And Heating Cycles Of The Equipment.All Equipment Warranties Per The Terms And Conditions Of The Manufacturer. Armstrong Equipment For This Application Qualifies For A Ten Year Limited Parts Warranty With A Standard Twenty Year Parts Warranty On The Heat Exchangers. Please Review All Manufacturer Warranty Certificates For Full Details Of Warranties.Dye Plumbing & Heating Warranty: We Offer A Two Year Material And Labor Warranty For The Work Provided. This Warranty Does Not Include Standard Maintenance Procedures (annual Cleaning, Filter Changes, Etc).
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Investigated And Found Handle On Zurn Flushometer Sticking In Downward Position. Replaced Handle Assembly And Tested Operation. Inspected Two Toilets In Same Rest Room. Found Middle Toilet Leaking A Large Amount Of Water When Cycled From Vacuum Breaker. Replaced Failed Component And Tested.
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Investigated Well Operation And Found Well Cycling Properly Between 30/50 Psi. Investigated Incoming Water Piping. Found Whole House Filter. Removed And Observed Filter To Be Clogged. Client Would Like To Have Softener Company Replace Filter. Left Filter Out Of Housing And Inspected Pressure. Found Much Better Pressure At Fixtures.
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Observed Whole House Plumbing System Backing Up. Checked Septic To See If Needed Pumped. Once Back Indoors Whole House Plumbing System Drained And Siphoned All Traps Dry. Flushed Toilet And Observed Proper Function With Leak Around Base. Pulled Toilet To Reset And Cameraed Line As Well. Observed No Obstructions. Reset Toilet And Tested Along With All Fixtures, Draining Properly At This Time.
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Found Main Water Closet Unable To Flush. Used Toilet Auger To Clear Trap Way Multiple Times To Remove Obstructions. Tested Operation By Cycling Water Closet Multiple Times.
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Call To Replace Customer Provided Sump Pump. Replaced Client Provided 3/4 Hp Sump Pump Replaced Check Valve And Near Piping. Tested New Pump For Proper Operation. Pump Is Operating Properly At This Time.
LaPorte, IN
03-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Found Kitchen Sink Not Draining Properly. Ran Auger Out 30’ Multiple Times To Clear Obstructions. Tested Operation By Cycling Large Amounts Of Hot Water With No Issues Draining At This Time. Unable To Input Card Will Call For Payment. Client Would Like Mailed Receipt.
LAPORTE, IN
03-31-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
INSTALLED NEW WATER SUPPLY, DRAINAGE PIPING, GAS PIPING AND DRYER VENT TO MOVE WASHER AND DRYER UPSTAIRS FROM BASEMENT.
LaPorte, IN
03-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Call For No Heat. Upon Arrival Found Furnace In Lockout Due To Pressure Switch Fault. After Further Investigation Found Condensate Drain Line Plugged Leading To Sump Pit. Cleared All Drains And Inspected Heat Exchangers. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 69 Degrees.
LaPorte, IN
03-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Observed Standing Water In Outdoor Cleanout. Augered 50’ To City Main And 25’ Towards Home Multiple Times To Clear Obstructions. Found Severe Separation At Cleanout Connection To Clay Tile And Numerous More From Cleanout To Main Sewer. Observed Proper Flow At This Time.
LaPorte, IN
03-28-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Found Flapper In Employee Bathroom And Customer Bathroom Leaking Through. Changed Flappers And Tested Operation By Cycling Water Closets Multiple Times. Found No Drips, Leaks, Or Issues With Any Other Fixtures Or Flushometers.
LaPorte, IN
03-26-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Call For No Heat. Upon Arrival Found Boiler System With No Pressure And Not Operating. Pressurized Boiler And Boiler System Piping. Could Not Determine Any Leaks At This Time. After Further Investigation Found Failed Roll-out Safety Switch. Found Chimney Clean Out Cover Forced Open From Chimney Debri Which Allowed Boiler To Vent Into The Home And Burn Incorrectly. Boiler Sections Are Sooted To The Point Of Boiler Failure. Gathered Information To Provide An Estimate For A Replacement Boiler System. Client Will Receive The Estimate Via Email When Completed. Left Power To Wi-if Thermostat On For Remote Temperature Monitoring.
LaPorte, IN
03-26-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Investigated And Found Client Had Just Done Laundry. Found Sump Pump Plugged Into A Non Grounded Extension Cord. Unplugged From Extension Cord And Plugged Directly Into Outlet. Pump Functioning Properly And Expelled Entire Pit Content. Augered Lavatory Sink Drain Line. Found Line Sludgy. Ran Large Amount Of Water After Augered. Lavatory Draining Proper At This Time. Recommend Dedicating An Outlet To Serve Sump Pump.
LaPorte, IN
03-24-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Found Kitchen Sink With Standing Water In Drain. Augered Kitchen Sink Drain. Reassembled Trap Way And Ran Large Amount Of Water To Flush Line And Test Operation. Observed Proper Flow.
LAPORTE, IN
03-23-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Located Underground Sewer Piping Near House Outdoors. Excavated Area And Unearthed Pipe. Found Cast Iron Separation Near Foundation. Removed Section Of Disjointed Piping To Area With Proper Pitch. Installed New 4” Pvc Piping And Clean Out. Flushed Toilet And Ran Water In Fixtures. Observed Proper Flow Through Repaired Piping. Backfilled Site And Bedded Piping.
Laporte, IN
03-23-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Performed Water Heater Flush And Cleaned Combustion Components. Install One New Full Port Brass Ball Valve For Future Maintenance.