Water or Steam Boiler Repair

Dye Plumbing & Heatingstarstarstarstarstar4.9 / 5

375 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Water Or Steam Boiler Repair La Porte, Indiana

If your heating system in La Porte, IN is not working it is likely your boiler needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on hot water or steam boiler systems like yours in La Porte, IN. Dye Plumbing & Heating service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our boiler repair, service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly.

Get Your Quote Today



Dye Plumbing & Heating Water Or Steam Boiler Repair La Porte, Indiana



Recent Water Or Steam Boiler Repair La Porte, Indiana by Dye Plumbing & Heating

Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Call To Service Boiler System And Investigate Possible Zone Not Working. Upon Arrival Found Leaking Zone Valve, Failed Basement Thermostat And Failed Circulator Pump. Serviced Boiler Per Clients Request, Cleaned Burners, Cleaned Pilot Assembly, Replaced Thermocouple, Tested Relief Valve, Drained Expansion Tank And Tested Fill Reducing Valve. Replaced Circulator Pump, Basement Thermostat And Dining/kitchen Zone Valve. Filled And Purged Boiler Of Air. Found Dining/kitchen Zone Frozen Somewhere In The Inaccessible Piping. Isolated Supply And Return For Kitchen/dining Zone And Cycled Boiler From All Zones. Boiler Cycles Off At 190° With A Pressure Of Approximately 18 PSIG. All Radiation Is Heating Properly Except The Isolated Kitchen Zone. Client Is To Attempt To Thaw Piping And Call For Further Repairs In The Future.
La Porte, IN
01-28-2022

Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Call For Boiler Pump Making Noise. Upon Arrival Found Boiler System Satisfied At Both Thermostats. Cycled System From Both Thermostats Several Times And Found Circulator Pumps Operating Properly. Found System Pressure At Approximately 8 PSIG With Air In The System. Increased Pressure To Approximately 14 PSIG, Tested Relief Valve And Purged Air From Salon Radiation. Observed System Cycle Off At 170° With A Pressure Of Approximately 20 PSIG. Could Not Determine Any Issues With The System Other Than System Containing Air. Boiler System Has Very Few Air Bleeders And An Inoperable Boiler Drain. Highly Recommend Considering Replacement Of The Boiler System Due To Its Age And Inefficiency.
La Porte, IN
01-28-2022

Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Call For Boiler System Leaking A Water. Upon Arrival Found Outlet Side Dielectric Union Leaking. Replaced Union With A New Propress Female Adapter, Filled System To Approximately 12 PSIG, Purged Air And Observed System Operation From All Space Heating Zones. All Zones Are Heating And The Boiler Cycles Off At 190° With A Pressure Of Approximately 20 PSIG. Found Indirect Water Heating Loop With A Banging Check Valve. Client Requests An Estimate For A New Check Valve To Be Installed As Soon As Possible.
La Porte, IN
01-24-2022

Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Two Zone Weil McLain Boiler Cold At 15 PSIG. Found Vent Damper Motor Malfunctioning And Found Locked Up Circulator Pump Serving West End Of The Building. East End Circulator Pump Bearings Are Noisy And Relief Valve Needs Replaced. Recommend Having Boiler System Serviced, Both Circulator Pumps Replaced, New Relief Valve Installed And A New Vent Damper Motor Replaced. Need To Contact Client With Price And Availability For The Mentioned Repairs.
La Porte, IN
01-24-2022

starstarstarstarstar
5 Star Rating
Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Call For One Of Four Circulator Pumps Making Noise. Upon Arrival Found Broken B&G Coupling. Replaced Coupling And Cycled Pump To Ensure Proper Operation. Added Additional Oil To The Motor And Bearing Assembly And Observed System Operation. Recommend Having Boiler Serviced Annually For Preventative Maintenance Purposes.
La Porte, IN
11-15-2021

Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Call For Pilot Light Out On Boiler System. Upon Arrival Found Failed Thermocouple And Water Dripping From Hot Water Domestic Piping Above Boiler. Replaced Thermocouple And Cycled Boiler To Ensure Proper Operation. All Radiation Is Heating Properly At This Time And The Boiler Cycles Off At 180° With A Pressure Of Approximately 16 PSIG. Also Found 1/2” CPVC Elbow Leaking. Replaced Elbow And Adjacent Fittings. Energized Hot Water Piping And Checked For Leaks. No Further Leaks Are Present At This Time.
La Porte, IN
02-26-2021

Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Provided And Installed A New Fill Reducing Valve, Check Valve And Expansion Tank Per Estimate Details. Also Replaced Leaking Boiler Drain And Bled System Of Air. Cycled Boiler From All Zones To Ensure Proper Operation. System Cycles Off At 140° With A Pressure Of Approximately 15 PSIG.
La Porte, IN
02-18-2021

Water Or Steam Boiler Repair La Porte, Indiana
Technician Invoice Notes: Call For Gas Smell In Boiler Room And Request For Boiler Service. Upon Arrival Searched For Gas Leak And Found Substantial Leak On 2” Main Elbow. Repaired Gas Piping And Checked All Remaining Joints For Leaks. Also Serviced Boiler System, Cleaned Burners, Cleaned Pilot Assembly, Replaced Thermocouple, Drained Expansion Tank, Tested Relief Valve, Tested Reducing Valve, Inspected Heat Exchanger Sections And Tested Boiler To Ensure Proper Operation. Boiler Cycles Off At 140° With A Pressure Of Approximately 14 PSIG.
La Porte, IN
01-25-2021

©MPN Media & Marketing 2024