Boiler Maintenance

Dye Plumbing & Heatingstarstarstarstarstar4.7 / 5

435 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Boiler Maintenance La Porte, Indiana

Are you looking for gas boiler maintenance in La Porte, IN ? Our heating and boiler service technicians have years of experience working on boilers like yours in La Porte, IN. Dye Plumbing & Heating has service vehicles on call that are fully equipped with the tools and parts necessary to get your gas boiler back up and operating. We work on traditional and wall hung boilers.

We offer gas boiler maintenance and maintenance agreements to keep your heating system running great. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency boiler today.

We provide gas boiler Maintenance in La Porte, IN

We provide gas boiler Maintenance Agreements in La Porte, IN

Get Your Quote Today



Dye Plumbing & Heating Boiler Maintenance La Porte, Indiana



Recent Boiler Maintenance La Porte, Indiana by Dye Plumbing & Heating

Boiler Maintenance La Porte, Indiana
Technician Invoice Notes: Serviced Boiler System. Cleaned Burners, Cleaned Pilot Assembly, Inspected Heat Exchanger Sections, Drained Expansion Tank, Tested Relief Valve, And Set Fill Reducing Valve To Approximately 13 PSIG. Cycled Boiler From The Thermostat And Bled All Radiation. Boiler Cycles Off At 190° With A Pressure Of Approximately 20 PSIG.
La Porte, IN
11-15-2021

Boiler Maintenance La Porte, Indiana
Technician Invoice Notes: Serviced Boiler System. Cleaned Pilot Assembly, Inspected Fire Bricks And Heat Exchanger And Oiled Circulator Pump. Verified System Has An Open Loop Expansion Tank With Open Discharge. Cycled Boiler From The Thermostat And All Radiation Is Heating Properly At This Time. Boiler Cycles Off At 160° With A Pressure Of Approximately 15 PSIG. Recommended Installing Carbon Monoxide Detectors Throughout The Home As An Added Safety Precaution. Also Recommended Considering Replacement Of The Boiler System Due To Its Age And Inefficiency.
La Porte, IN
10-22-2021

Boiler Maintenance La Porte, Indiana
Technician Invoice Notes: Serviced Forced Air Furnace In The Barn. Cleaned Burners, Cleaned Flame Sensor, Cleaned Spark Igniter, Cleaned Inducer Signal Port, Inspected Blower Wheel, Inspected Air Filter, And Inspected Primary Heat Exchanger Cells. Furnace Is Heating Properly At This Time With A Temperature Rise Of 47°. Serviced Boiler System. Inspected Burners And Heat Exchanger Sections. Cleaned Pilot Assembly, Oiled B&G Circulator Pump, Tested Relief Valve, Tested Fill Valve And Cycled Boiler From Both Zones To Ensure Proper Operation. All Radiation Is Heating Properly At This Time And The Boiler Cycles Off At 185° With A Pressure Of Approximately PSIG.
La Porte, IN
10-22-2021

Boiler Maintenance La Porte, Indiana
Technician Invoice Notes: Serviced Boiler System. Cleaned Burners, Cleaned Pilot Assembly, Inspected Vent, Inspected Heat Exchanger And Oiled Circulator Pump. Tested Relief Valve And Auto Fill Reducing Valve For Proper Operation. Cycled Boiler From All Three Zones And Observed Unit Operation. System Is Heating Properly At This Time And Cycles Off At 180 Degrees With A Pressure Of Approximately 20 Psi. Recommend Having Boiler Serviced Annually For Preventative Maintenance Purposes. Client Would Like A Mailed Receipt.
La Porte, IN
02-08-2021

starstarstarstarstar
5 Star Rating
Boiler Maintenance La Porte, Indiana
Technician Invoice Notes: Serviced Boiler For The Upcoming Heating Season. Cleaned Burners, Cleaned Spark Ignition Components, Inspected Heat Exchanger Sections, Inspected Vent, Oiled Main Circulator Pump, Drained Expansion Tank, Set Reducing Valve To 12 PSIG And Tested Relief Valve. Cycled Boiler To Ensure Proper Operation And Unit Cycles Off At 180° With A Pressure Of Approximately 22 PSIG. Client Would Like A Phone Call To Schedule Next Years Boiler Service.
La Porte, IN
11-06-2020

Boiler Maintenance La Porte, Indiana
Technician Invoice Notes: Call To Service Boiler System And Two Gas Furnaces. Serviced Boiler System. Cleaned Burners, Cleaned Flame Sensor And Spark Ignition Components, Tested Relief Valve And Cycled Boiler To Ensure Proper Operation. Tested All Four Zones And Observed Boiler Cycle Off At 180° With A Pressure Of Approximately 20 PSIG. Serviced Main And Bedroom Furnaces. Cleaned Burners, Cleaned Flame Sensors, Measured Igniter Resistance At 33 Ohms On Main Furnace, Cleaned Condensate Traps, Replaced Client Supplied Air Filters And Inspected Primary And Secondary Heat Exchangers. Cycled Main Furnace And Unit Is Heating Properly At This Time With A Temperature Rise Of 42°. Found Chipmunk In Bedroom Furnace. Replaced Hot Surface Igniter Due To Chipmunk Damage. After Further Investigation Found Failed Control Board For Bedroom Furnace. Need To Call Client With Pricing And Availability For A Replacement Control Board.
La Porte, IN
08-26-2020

©Red Barn Media Group 2024